Skip to content

The Rotational Insertion Technique for ProSeal Laryngeal Mask Airway

The 90-degree Rotational Insertion Technique for the Large Size ProSeal Laryngeal Mask Airway

Status
Completed
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT00966186
Enrollment
120
Registered
2009-08-26
Start date
2008-11-30
Completion date
2009-05-31
Last updated
2010-08-16

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Elective Surgery, General Anesthesia

Keywords

ProSeal Laryngeal Mask Airway, Rotational technique, Success rate, Postoperative complications

Brief summary

The purpose of this study is to compare two insertion techniques of large size ProSeal laryngeal mask airway. We hypothesized that insertion of ProSeal laryngeal mask airway with 90-degree rotation would reduce the contact surface between the device and pharyngeal wall and make it easy to advance the device over the smooth angle against the posterior pharyngeal wall.We compared the success rate and incidence of complication of the standard technique with the rotational technique.

Detailed description

ProSeal laryngeal mask airway is not easy to be inserted due to its larger cuff especially in Asian population. First-time insertion success rate was lower and more time was required to achieve an effective airway even in well-trained physician. A number of techniques have been described to improve the insertion success rate. However, these techniques are only recommended to be used as backup when the digital or introducer tool techniques fail. We hypothesized that insertion of ProSeal laryngeal mask airway with 90-degree rotation would reduce the contact surface between the device and pharyngeal wall and make it easy to advance the device over the smooth angle against the posterior pharyngeal wall.We compared the success rate and incidence of complication of the standard technique with the rotational technique.

Interventions

PROCEDUREInsertion fo ProSeal laryngeal mask airway

Insertion fo ProSeal laryngeal mask airway using each of Standard technique or Rotational technique

Sponsors

Seoul National University Hospital
Lead SponsorOTHER

Study design

Allocation
RANDOMIZED
Intervention model
PARALLEL
Masking
SINGLE (Subject)

Eligibility

Sex/Gender
ALL
Age
27 Years to 75 Years
Healthy volunteers
No

Inclusion criteria

* American Society of Anesthesiologists physical status I-II

Exclusion criteria

* Predicted difficult airway * Mouth opening less than 2.5 cm * Present sore throat * High risk of aspiration

Design outcomes

Primary

MeasureTime frame
Success of Insertion at First Attempt5 minute

Secondary

MeasureTime frame
Insertion Time, Sealing Pressure and Complication5 min - 4 hours

Countries

South Korea

Participant flow

Participants by arm

ArmCount
Standard Technique
Proseal laryngeal mask airway was inserted according to the manufacture's instruction manual
60
Rotational Technique60
Total120

Baseline characteristics

CharacteristicRotational TechniqueStandard TechniqueTotal
Age, Categorical
<=18 years
0 Participants0 Participants0 Participants
Age, Categorical
>=65 years
4 Participants8 Participants12 Participants
Age, Categorical
Between 18 and 65 years
56 Participants52 Participants108 Participants
Age Continuous47.4 years
STANDARD_DEVIATION 10.7
49.6 years
STANDARD_DEVIATION 12.9
48.5 years
STANDARD_DEVIATION 11.8
Region of Enrollment
Korea, Republic of
60 participants60 participants120 participants
Sex: Female, Male
Female
22 Participants23 Participants45 Participants
Sex: Female, Male
Male
38 Participants37 Participants75 Participants

Adverse events

Event typeEG000
affected / at risk
EG001
affected / at risk
deaths
Total, all-cause mortality
— / —— / —
other
Total, other adverse events
0 / 600 / 60
serious
Total, serious adverse events
0 / 600 / 60

Outcome results

Primary

Success of Insertion at First Attempt

Time frame: 5 minute

ArmMeasureValue (NUMBER)
Standard TechniqueSuccess of Insertion at First Attempt50 participants
Rotational TechniqueSuccess of Insertion at First Attempt60 participants
Secondary

Insertion Time, Sealing Pressure and Complication

Time frame: 5 min - 4 hours

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026