Skip to content

Exercise, Oxidative Stress and HIV

A Case-control Study to Test the Effects of a Bout of Aerobic Exercise Followed by Resistance Training on Antioxidant System in Human Immunodeficiency Virus (HIV)-Infected and Non-HIV Subjects

Status
Completed
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT00950937
Enrollment
28
Registered
2009-08-03
Start date
2006-06-30
Completion date
2008-07-31
Last updated
2009-08-11

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

HIV Infections

Brief summary

The purpose of this study is to compare oxidative stress markers and the immunologic characteristics of HIV-infected and non-HIV subjects during a bout of moderate aerobic exercise followed by resistance exercises

Interventions

None listed

Sponsors

Hospital de Clinicas de Porto Alegre
Lead SponsorOTHER

Study design

Observational model
CASE_CONTROL
Time perspective
PROSPECTIVE

Eligibility

Sex/Gender
ALL
Age
20 Years to 55 Years
Healthy volunteers
Yes

Inclusion criteria

* HIV Group:without contraindications for exercise training; to highly active antiretroviral therapy (HAART) for at least 6 months before enrollment; be classified as low level of physical activity by international physical activity questionnaire (IPAQ) and did not use antioxidant supplements. * Control Group:negative result for HIV-1 test and the other criteria described above

Exclusion criteria

* Subjects with previous history of cardiovascular and neurological disease, diabetes, dyslipidemia, tobacco using, physical disability and pregnant women were excluded from the study.

Design outcomes

Primary

MeasureTime frameDescription
Total Glutathione3 times - baseline (before the peak oxygen uptake test), aerobic (immediately after aerobic exercise) and resistance (immediately after resistance exercise).The total glutathione content in erythrocyte concentrate at three moments: baseline, aerobic and resistance exercise.

Secondary

MeasureTime frameDescription
Glutathione S-transferase (GST)3 times - baseline (before the peak oxygen uptake test), aerobic (immediately after aerobic exercise) and resistance (immediately after resistance exercise).Antioxidant activity of the Glutathione S-transferase enzyme at three moments: baseline, aerobic and resistance exercise.
Lipid Peroxidation3 times - baseline (before the peak oxygen uptake test), aerobic (immediately after aerobic exercise) and resistance (immediately after resistance exercise).Thiobarbituric acid-reactive substances (TBARS) assay was used as an index of lipid peroxidation in erythrocytes, at three moments: baseline, aerobic and resistance exercise.
Catalase Activity3 times - baseline (before the peak oxygen uptake test), aerobic (immediately after aerobic exercise) and resistance (immediately after resistance exercise).Antioxidant activity of the catalase enzyme at three moments: baseline, aerobic and exercise.
Neutrophil Count3 times - baseline (before the peak oxygen uptake test), aerobic (immediately after aerobic exercise) and resistance (immediately after resistance exercise).Neutrophil count at three moments: baseline, aerobic and resistance exercise.
Peak Oxygen Uptake1 time, before the exercise protocolIs the maximum capacity of an individual's body to transport and utilize oxygen during incremental exercise.
T CD43 times - baseline (before the peak oxygen uptake test), aerobic (immediately after aerobic exercise) and resistance (immediately after resistance exercise).T CD4 lymphocytes counts at three moments: baseline, aerobic and resistance exercise.

Countries

Brazil

Participant flow

Participants by arm

ArmCount
HIV Group
HIV infected persons
14
Control Group
Non HIV-infected persons
14
Total28

Baseline characteristics

CharacteristicControl GroupHIV GroupTotal
Age, Categorical
<=18 years
0 Participants0 Participants0.0 Participants
Age, Categorical
>=65 years
0 Participants0 Participants0.0 Participants
Age, Categorical
Between 18 and 65 years
14 Participants14 Participants28.0 Participants
Age Continuous36 years
STANDARD_DEVIATION 10.6
39.2 years
STANDARD_DEVIATION 8.7
37.5 years
STANDARD_DEVIATION 9.5
Region of Enrollment
Brazil
14 participants14 participants28.0 participants
Sex: Female, Male
Female
7 Participants7 Participants14.0 Participants
Sex: Female, Male
Male
7 Participants7 Participants14.0 Participants

Outcome results

Primary

Total Glutathione

The total glutathione content in erythrocyte concentrate at three moments: baseline, aerobic and resistance exercise.

Time frame: 3 times - baseline (before the peak oxygen uptake test), aerobic (immediately after aerobic exercise) and resistance (immediately after resistance exercise).

ArmMeasureGroupValue (MEDIAN)
HIV GroupTotal GlutathioneBaseline1,964 nmoles glutathione/ ml of sample
HIV GroupTotal GlutathioneAerobic1,865 nmoles glutathione/ ml of sample
HIV GroupTotal GlutathioneResistance1,767 nmoles glutathione/ ml of sample
Control GroupTotal GlutathioneBaseline3,490 nmoles glutathione/ ml of sample
Control GroupTotal GlutathioneAerobic3,995 nmoles glutathione/ ml of sample
Control GroupTotal GlutathioneResistance3,206 nmoles glutathione/ ml of sample
p-value: <0.05Wilcoxon (Mann-Whitney)
p-value: <0.05Friedman Test
p-value: <0.05Friedman Test
Secondary

Catalase Activity

Antioxidant activity of the catalase enzyme at three moments: baseline, aerobic and exercise.

Time frame: 3 times - baseline (before the peak oxygen uptake test), aerobic (immediately after aerobic exercise) and resistance (immediately after resistance exercise).

ArmMeasureGroupValue (MEDIAN)
HIV GroupCatalase ActivityBaseline0.578 units of catalase /mg protein
HIV GroupCatalase ActivityResistance0.566 units of catalase /mg protein
HIV GroupCatalase ActivityAerobic1.03 units of catalase /mg protein
Control GroupCatalase ActivityResistance1.009 units of catalase /mg protein
Control GroupCatalase ActivityBaseline0.967 units of catalase /mg protein
Control GroupCatalase ActivityAerobic0.855 units of catalase /mg protein
p-value: <0.05Wilcoxon (Mann-Whitney)
p-value: <0.05Friedman Test
p-value: <0.05Friedman Test
Secondary

Glutathione S-transferase (GST)

Antioxidant activity of the Glutathione S-transferase enzyme at three moments: baseline, aerobic and resistance exercise.

Time frame: 3 times - baseline (before the peak oxygen uptake test), aerobic (immediately after aerobic exercise) and resistance (immediately after resistance exercise).

ArmMeasureGroupValue (MEDIAN)
HIV GroupGlutathione S-transferase (GST)Baseline0.34 micromol of GST/min/mg of protein
HIV GroupGlutathione S-transferase (GST)Aerobic0.34 micromol of GST/min/mg of protein
HIV GroupGlutathione S-transferase (GST)Resistance0.45 micromol of GST/min/mg of protein
Control GroupGlutathione S-transferase (GST)Baseline0.5 micromol of GST/min/mg of protein
Control GroupGlutathione S-transferase (GST)Aerobic0.36 micromol of GST/min/mg of protein
Control GroupGlutathione S-transferase (GST)Resistance0.46 micromol of GST/min/mg of protein
p-value: <0.05Wilcoxon (Mann-Whitney)
p-value: <0.05Friedman Test
p-value: <0.05Friedman Test
Secondary

Lipid Peroxidation

Thiobarbituric acid-reactive substances (TBARS) assay was used as an index of lipid peroxidation in erythrocytes, at three moments: baseline, aerobic and resistance exercise.

Time frame: 3 times - baseline (before the peak oxygen uptake test), aerobic (immediately after aerobic exercise) and resistance (immediately after resistance exercise).

ArmMeasureGroupValue (MEDIAN)
HIV GroupLipid PeroxidationAerobic2.328 picomol of TBARS/mg protein
HIV GroupLipid PeroxidationResistance2.348 picomol of TBARS/mg protein
HIV GroupLipid PeroxidationBaseline2.356 picomol of TBARS/mg protein
Control GroupLipid PeroxidationBaseline2.888 picomol of TBARS/mg protein
Control GroupLipid PeroxidationResistance3.205 picomol of TBARS/mg protein
Control GroupLipid PeroxidationAerobic4.164 picomol of TBARS/mg protein
p-value: <0.05Wilcoxon (Mann-Whitney)
p-value: <0.05Friedman Test
p-value: <0.05Friedman Test
Secondary

Neutrophil Count

Neutrophil count at three moments: baseline, aerobic and resistance exercise.

Time frame: 3 times - baseline (before the peak oxygen uptake test), aerobic (immediately after aerobic exercise) and resistance (immediately after resistance exercise).

ArmMeasureGroupValue (MEDIAN)
HIV GroupNeutrophil CountAerobic3,285 Cell/ul of blood
HIV GroupNeutrophil CountBaseline3,237 Cell/ul of blood
HIV GroupNeutrophil CountResistance3,511 Cell/ul of blood
Control GroupNeutrophil CountBaseline3,212 Cell/ul of blood
Control GroupNeutrophil CountAerobic3,476 Cell/ul of blood
Control GroupNeutrophil CountResistance3,563 Cell/ul of blood
p-value: <0.05Wilcoxon (Mann-Whitney)
p-value: <0.05Friedman Test
p-value: <0.05Friedman Test
Secondary

Peak Oxygen Uptake

Is the maximum capacity of an individual's body to transport and utilize oxygen during incremental exercise.

Time frame: 1 time, before the exercise protocol

ArmMeasureValue (MEDIAN)Dispersion
HIV GroupPeak Oxygen Uptake1,673 ml/minStandard Deviation 349
Control GroupPeak Oxygen Uptake2,167 ml/minStandard Deviation 597
p-value: <0.05t-test, 2 sided
Secondary

T CD4

T CD4 lymphocytes counts at three moments: baseline, aerobic and resistance exercise.

Time frame: 3 times - baseline (before the peak oxygen uptake test), aerobic (immediately after aerobic exercise) and resistance (immediately after resistance exercise).

ArmMeasureGroupValue (MEDIAN)
HIV GroupT CD4Aerobic428 Cell/ul of blood
HIV GroupT CD4Resistance378 Cell/ul of blood
HIV GroupT CD4Baseline417 Cell/ul of blood
Control GroupT CD4Aerobic968 Cell/ul of blood
Control GroupT CD4Baseline984 Cell/ul of blood
Control GroupT CD4Resistance974 Cell/ul of blood
p-value: <0.05Wilcoxon (Mann-Whitney)
p-value: <0.05Friedman Test
p-value: <0.05Friedman Test

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026