Skip to content

Accuracy of the Galilei Analyzer to Calculate the Effective Corneal Power After Corneal Refractive Surgery

Accuracy of the Galilei Analyzer to Calculate the Effective Corneal Power After Corneal Refractive Surgery

Status
Terminated
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT00934804
Acronym
Galilei
Enrollment
7
Registered
2009-07-08
Start date
2009-06-30
Completion date
2009-10-31
Last updated
2018-07-23

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Cataracts

Keywords

refractive surgery

Brief summary

The purpose of this study is to determine the accuracy of the Galilei corneal analyzer to calculate the effective corneal power (keratometry, corneal curvature) in patients who have undergone both corneal refractive surgery and lens extraction with intraocular lens implantation.

Detailed description

The accuracy of IOL calculation is important for the visual outcome of patients undergoing cataract extraction and IOL implantation. Different formulas such as Holladay I, HofferQ, SRKT have been used with excellent results. All formulas use the corneal power among other factors to calculate the IOL power. Corneal refractive surgery i.e. radial keratotomy (RK), photorefractive keratectomy (PRK), and Laser in situ keratomileusis (LASIK) changes the corneal power; therefore, it is difficult to measure the true corneal power after surgery by any form of direct measurement, such as keratometry, or corneal topography. Keratometry and topography assume a normal relationship between the anterior and posterior corneal curvatures, and measure the anterior corneal radius. RK for myopia flattens both the anterior corneal radius and the posterior corneal radius while PRK and LASIK for myopia flattens the anterior corneal radius but leaves the posterior corneal radius mostly unchanged. Standard keratometry measures an intermediate area and extrapolates the central power based on some very broad assumptions. For this reason, keratometry, autokeratometry and simulated keratometry by topography will typically over-estimate central corneal power following keratorefractive surgery for myopia. This inaccuracy leads to an inability to meet the patients' rising expectations and with the increasing popularity of refractive surgery, calculating intraocular lens (IOL) power after refractive surgery is becoming increasingly important. Different methods to calculate the effective corneal power (keratometry) after refractive surgery have been described (historical data, effective refractive power, modified Maloney method, etc), however, intraocular lens power calculations in eyes with previous refractive surgery remains difficult because of the inaccuracy of keratometry power measurements. The Galilei dual Scheimpflug analyzer is a non-invasive, diagnostic system that combines dual rotating Scheimpflug camera measurements and Placido optical system for corneal topography and 3D analysis of the anterior eye segment. It provides pachymetry as well as elevation and curvature mapping of the cornea. Additionally, the Ray tracing system delivers a more accurate total corneal power and anterior chamber depth. The total corneal power that the Galilei provides is an alternative that seems to be more accurate to calculate the IOL power in patients who have undergone keratorefractive surgery prior to cataract extraction and IOL implantation. The purpose of this study is to determine the accuracy of the Galilei to calculate the effective corneal power (keratometry, corneal curvature) in patients who have undergone both corneal refractive surgery and lens extraction with intraocular lens implantation.

Interventions

DEVICEGalilei dual Scheimpflug analyzer

The Galilei dual Scheimpflug analyzer is a non-invasive, diagnostic system that combines dual rotating Scheimpflug camera measurements and Placido optical system for corneal topography and 3D analysis of the anterior eye segment.

Sponsors

Medical University of South Carolina
Lead SponsorOTHER

Study design

Allocation
NON_RANDOMIZED
Intervention model
SINGLE_GROUP
Primary purpose
DIAGNOSTIC
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
40 Years to 80 Years
Healthy volunteers
Yes

Inclusion criteria

* Subjects MUST fulfill the following conditions to qualify for enrollment into the trial: * Subject must have undergone corneal refractive surgery (RK, PRK or LASIK) prior to cataract extraction. * Age: 40 to 80 years old. * Subjects must have undergone cataract extraction at least 4 weeks prior to enrollment in this trial. * Willing and able to comply with scheduled visits and other study procedures.

Exclusion criteria

Subjects with ANY of the following conditions on the eligibility exam may NOT be enrolled into the trial. Preoperative ocular pathology: amblyopia, rubella cataract, proliferative diabetic retinopathy, shallow anterior chamber, macular edema, retinal detachment, aniridia or iris atrophy, uveitis, history of iritis, iris neovascularization, medically uncontrolled glaucoma, microphtalmus or macrophtalmus, optic nerve atrophy, macular degeneration (with anticipated best postoperative visual acuity less than 20/30), advanced glaucomatous damage, etc. Uncontrolled diabetes. Use of any systemic or topical drug known to interfere with visual performance. Contact lens use during the active treatment portion of the trial. Any concurrent infectious/non infectious conjunctivitis, keratitis or uveitis. Any clinically significant, serious or severe medical or psychiatric condition that may increase the risk associated with study participation or study device implantation or may interfere with the interpretation of study results. Participation in (or current participation) any investigational drug or device trial within the previous 30 days prior to the start date of this trial. Intraocular conventional surgery (other than cataract extraction) within the past three months or intraocular laser surgery within one month in the operated eye.