Skip to content

Evaluation of the Accuracy of the INRatio Prothrombin Time (PT) Monitoring System With a New Test Strip for the Oral Anticoagulation Therapy Patient in the Presence of Heparin and Low Molecular Weight Heparin (e.g., Enoxaparin or Dalteparin)

Status
Completed
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT00933738
Acronym
ECLIPSE 03
Enrollment
150
Registered
2009-07-07
Start date
2009-12-31
Completion date
2011-03-31
Last updated
2011-06-22

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Coagulation

Keywords

Patients needing OAT (Oral Anticoagulation Therapy)

Brief summary

This is a multi-center study designed to evaluate the heparin insensitivity of the INRatio Prothrombin Time (PT) Monitoring System, utilizing an INRatio test strip additionally modified for low sample volume. The INRatio test strip is used for the quantitative determination of PT and International Normalized Ratio (INR) results in fingerstick blood from subjects on oral anticoagulation therapy (OAT) with warfarin. This study is designed to evaluate the accuracy of the modified INRatio test strip during heparin-warfarin bridge therapy with unfractionated heparin (UH) or low molecular weight heparin (LMWH), such as enoxaparin or dalteparin. These INR results will be compared to the INR results obtained on plasma from the same subjects as analyzed at a central laboratory with the heparin-insensitive reference method: the Sysmex CA-560 System. The levels of UH or LMWH in the plasma samples will be assessed using activated partial thromboplastin time (aPTT) and anti-factor-Xa assays respectively.

Interventions

None listed

Sponsors

Abbott RDx Cardiometabolic
Lead SponsorOTHER

Study design

Observational model
CASE_ONLY
Time perspective
PROSPECTIVE

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* Adults (18 years of age or older). * Willing and able to provide written informed consent and comply with study procedures. * Receiving warfarin/heparin bridge therapy. * Therapy with both warfarin and one of the heparins listed below must have been initiated for at least 12 hours before the first study specimens are obtained. * UH (last known aPTT prior to enrollment (if available†) must confirm heparin has been administered) * Dalteparin (last known anti-factor Xa prior to enrollment (if available†) must confirm heparin has been administered) * Enoxaparin (last known anti-factor Xa prior to enrollment (if available†) must confirm heparin has been administered) † If a pre-study aPTT or anti-factor Xa is not available, subsequent testing of the study phlebotomy or a phlebotomy as a part of routine medical care taken before or during the time of the study phlebotomy must confirm the presence of heparin (unfractionated or low molecular weight) in order for that data point to be included in the analysis.

Exclusion criteria

* Known or suspected hematocrit less than 25 or greater than 55%; * Auto-immune disorders known to interfere with INR measurements, such as lupus or anti-phospholipid syndrome (APS) * Already participated in this specific study

Countries

United States