Colonoscopy
Conditions
Keywords
colonoscopy, MoviPrep
Brief summary
This study will evaluate whether morning-only dosing of MoviPrep® (2L) for afternoon colonoscopy is as effective as a standard dosing regimen of half of the volume of MoviPrep® (1L) solution the evening prior, and half (1L) the morning of, colonoscopy. MoviPrep® is a low volume (2 liters) polyethylene glycol (PEG)-based purgative that is approved for evening-only or split (evening and morning) dosing to cleanse the colon prior to colonoscopy. Patients undergoing afternoon colonoscopies often have inferior colon cleansing. There is evidence that morning-only purgative administration of large volume PEG (4L) is safe and effective. This study will assess whether administration of a low volume PEG regimen will maintain efficacy and improve tolerance by changing a 2-day preparation procedure into a regimen that is completed in 1 day.
Detailed description
primary objectives • To compare the efficacy of morning dose only MoviPrep® (AM Dosing) where one-half of the prep is given 7 hours before colonoscopy and the second half is given 4 hours before colonoscopy, versus split dose (PM/AM) MoviPrep® (PM/AM Dosing) where one-half of the prep is given at 6pm the night prior to colonoscopy and the second half is given 4 hours before colonoscopy. Efficacy will be assessed based on cleansing of the entire colon, with successful cleansing defined as a score of excellent or good and unsuccessful cleansing defined as a score of fair or poor. Secondary objectives * To assess the tolerability of AM Dosing MoviPrep® versus PM/AM Dosing MoviPrep® based on percentage of prep completed, sleep quality/quantity, future prep choice (same prep or alternative prep described), and incidence and severity (using 11-point Likert scale) of any adverse events (i.e. nausea, vomiting, abdominal pain, bloating, light-headedness). * To evaluate the safety of each dosing administration based on vitals with orthostatic measures (BP, pulse) on day of colonoscopy. * To evaluate the effect of colon prep on work and productivity as measured by the degree of interference with work/productivity the day prior to colonoscopy. * To assess difference between two dosing arms with respect to analysis of right colon cleansing, and overall adenoma detection in terms of number, size, location, histology, and morphology. * To determine the effect of purgative dosing on procedure efficiency by measuring (a) total procedure time, (b) time from anus to cecum, and (c) withdrawal time (excluding time taken for interventions). * To evaluate the effect of purgative dosing regimen on amount of flushing required during the procedure (0 = none, 1 = \<50 ml, 2 = 50-100 ml, 3 = \>100 ml). * To validate a new grading scale for colon cleansing using the de-identified recordings of colonoscopies performed during this study.
Interventions
None listed
Sponsors
Study design
Eligibility
Inclusion criteria
* Elective out-patients scheduled for afternoon colonoscopy (12 pm or later).
Exclusion criteria
* Unable or unwilling to consent * Age \< 18 years * Pregnant * Breast feeding * Gastroparesis - known or suspected * Chronic nausea or vomiting * Bowel obstruction * Hypomotility syndrome: pseudo-obstruction, megacolon, etc. * Severe constipation (\< 1 BM a week) * Greater than 50% resection of colon * Glucose-6-Phosphate Dehydrogenase (G6PD) deficiency * PEG allergy * Significant psychiatric illness
Design outcomes
Primary
| Measure | Time frame |
|---|---|
| Comparing the efficacy of AM dose only MoviPrep® (1/2 the prep 7 hrs pre colonoscopy and the second 1/2 4 hrs pre colonoscopy), versus PM/AM where 1/2 of the prep is at 6pm the night prior to colonoscopy and the second half is 4 hours before colonoscopy. | once |
Secondary
| Measure | Time frame |
|---|---|
| To evaluate the safety of each dosing administration based on vitals with orthostatic measures (BP, pulse) on day of colonoscopy | once |
| To evaluate the effect of colon prep on work and productivity as measured by the degree of interference with work/productivity the day prior to colonoscopy. | once |
| To assess difference between two dosing arms with respect to analysis of right colon cleansing, and overall adenoma detection in terms of number, size, location, histology, and morphology. | once |
| To assess the tolerability of AM Dosing MoviPrep® versus PM/AM Dosing MoviPrep® based on % of prep completed, sleep quality/quantity, future prep choice (same prep or alternative prep described), and incidence and severity of any adverse events | once |
| To evaluate the effect of purgative dosing regimen on amount of flushing required during the procedure (0 = none, 1 = <50 ml, 2 = 50-100 ml, 3 = >100 ml). | once |
| To validate a new grading scale for colon cleansing using the de-identified recordings of colonoscopies performed during this study. | once |
| To determine the effect of purgative dosing on procedure efficiency by measuring (a) total procedure time, (b) time from anus to cecum, and (c) withdrawal time (excluding time taken for interventions). | once |
Countries