Healthy, Hypermetropia, Myopia
Conditions
Keywords
spectral domain-OCT, macular thickness, myopia, hypermetropia, normal
Brief summary
The purpose of this study is to analyze macular retinal thickness and macular volume using the spectral domain - optical coherence tomography (SD-OCT) in normal eyes and in eyes with various ocular diseases.
Detailed description
Assessment of macular thickness is important for the treatment and follow-up of a variety of ocular diseases. The introduction of optical coherence tomography (OCT) has enabled clinicians to reliably detect small changes in macular thickness and to quantitatively evaluate the efficacy of different therapeutic modalities. In this study using the spectral domain-OCT, we examined the variations of macular retinal thickness and macular volume in normal eyes and in eyes with various ocular diseases.
Interventions
macular cube scanning
Sponsors
Study design
Eligibility
Inclusion criteria
* normal eyes * myopic eyes * hypermetropic eyes
Exclusion criteria
* systemic illness * cataract * previous ocular trauma or surgery(other than cataract surgery or refractive surgeries)
Design outcomes
Primary
| Measure | Time frame |
|---|---|
| macular retinal thickness and volume | 3 months |
Countries
South Korea