Skip to content

Substrate Modification in Stable Ventricular Tachycardia in Addition to Implantable Cardioverter Defibrillator (ICD) Therapy

Substrate Modification in Stable Ventricular Tachycardia in Addition to ICD Therapy

Status
Completed
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT00919373
Acronym
VTACH
Enrollment
110
Registered
2009-06-12
Start date
2002-07-31
Completion date
2006-01-31
Last updated
2019-02-04

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Ventricular Tachycardia, Coronary Artery Disease, Left Ventricular Dysfunction

Keywords

Catheter Ablation, Defibrillators, Implantable

Brief summary

The main objective of this study is to compare the time from randomization to the first recurrence of any ventricular tachycardia (VT) in patients undergoing VT ablation (for stable VTs) and substrate ablation (for unstable VTs) after an initial episode of stable VT and patients not undergoing ablation, with both groups under the protection of an ICD.

Detailed description

The main objective of this study is to compare the time from randomization to the first recurrence of any VT in patients undergoing VT ablation (for stable VTs) and substrate ablation (for unstable VTs) after an initial episode of stable VT and patients not undergoing ablation, with both groups under the protection of an ICD. Prior to the ablation, the patients will undergo electrophysiologic study (EPS) with programmed ventricular stimulation, with the aim to reproduce the clinical VT. Most patients with coronary artery disease, systolic LV dysfunction, and one episode of clinical sustained VT have more than one inducible VT at electrophysiologic study. Since any inducible VT can become a potential clinical VT (24), an attempt will be made to ablate the clinical stable VT, as well as all inducible morphologies, stable or unstable. One of the following 2 ablation strategies will be possible for each VT: * Substrate modification in sinus rhythm in case of unstable induced monomorphic VT which does not allow mapping and ablation in tachycardia, or noninducible stable clinical VT. * VT ablation in tachycardia in case of stable VT For each procedure the number of tachycardias , the type of each tachycardia (inducible or noninducible, stable or unstable), the ablation strategy for each tachycardia (it is possible that lesions deployed for one tachycardia will render another tachycardia noninducible as well) and the procedural outcome for each tachycardia will be documented.

Interventions

PROCEDURESubstrate modification

Catheter Ablation procedure - Substrate modification in sinus rhythm in case of unstable induced monomorphic Ventricular Tachycardia (VT) which does not allow mapping and ablation in tachycardia, or noninducible stable clinical VT.

PROCEDUREVT ablation

Catheter Ablation of Ventricular Tachycardia (VT) in case of stable VT

Implantation of a marked released Implantable Cardioverter Defibrillator manufactured by St. Jude Medical

Sponsors

Abbott Medical Devices
Lead SponsorINDUSTRY

Study design

Allocation
RANDOMIZED
Intervention model
PARALLEL
Primary purpose
TREATMENT
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
18 Years to 80 Years
Healthy volunteers
No

Inclusion criteria

* Coronary artery disease For the purpose of this study, coronary artery disease will be defined as the presence of a 50 % or more diameter stenosis of the left main coronary artery, or 75 % or more diameter stenosis of the left anterior descending, circumflex or right coronary arteries, or the history of a surgical or percutaneous revascularization procedure, or history of successful thrombolysis, or a history of prior myocardial infarction (e.g.: documented by Q-wave, R-reduction, aneurysm) * Left ventricular ejection fraction ≤ 50 % as estimated by echocardiography or contrast ventriculography within the previous 30 days and evidence for old myocardial infarction (ECG, echocardiographic or venticulographic). * One episode of documented stable clinical VT without any reversible causes * Written informed consent

Exclusion criteria

* Age \< 18 years or \> 80 year * Protruding LV thrombus on pre-ablation echocardiogram * Acute myocardial infarction within the preceding 1 months * Class IV NYHA heart failure * Valvular heart disease or mechanical heart valve precluding access to the left ventricle * Unstable angina * Cardiac surgery involving cardiotomy (not CABG) within the past 2 months * Serum creatinine \> 220 mmol/L (2.5 mg/dL) * Thrombocytopenia or coagulopathy * Contraindication to heparin * Pregnancy * Acute illness or active systemic infection * Other disease process likely to limit survival to less than 12 months * Significant medical problem that in the opinion of the principal investigator would preclude enrollment in the study * Participation in another investigational study * Unwillingness to participate or lack of availability for follow-up * Incessant VT or electrical storm * Bundle branch reentry tachycardia as the presenting VT * Preexisting ICD

Design outcomes

Primary

MeasureTime frame
recurrence of any sustained clinical VT, stable or unstable, monomorphic or polymorphic, including VF, during the follow-up period2 years

Secondary

MeasureTime frame
Severe clinical events (death, number of syncopes, number of hospital admissions for a cardiac indication, number of episodes of electrical storm (more than 3 VT episodes in 24 hours)) during the follow-up period .2 years
Quality of life2 years
Number of adequate ICD interventions (shocks and overdrive episodes caused by recurrence of VT or VF and not supraventricular arrhythmias or mechanical lead problems).2 years

Countries

Czechia, Denmark, Germany, Switzerland

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Apr 1, 2026