Skip to content

Tracheal Intubation of Morbidly Obese Patients. GlideScope Versus Direct Laryngoscopy

Orotracheal Intubation of Morbidly Obese Patients. A Randomised Controlled Trial Comparing the GlideScope Videolaryngoscope to the Macintosh Direct Laryngoscope.

Status
Completed
Phases
Phase 4
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT00917033
Enrollment
100
Registered
2009-06-10
Start date
2008-09-30
Completion date
2009-10-31
Last updated
2010-02-24

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Anesthesia, General, Intubation, Endotracheal, Obesity

Brief summary

The purpose of this study is to examine whether orotracheal intubation in morbidly obese patients is faster, gentler and safer using the GlideScope videolaryngoscope than with the Macintosh direct laryngoscope.

Interventions

DEVICEGlideScope

Orotracheal intubation

DEVICEMacintosh direct laryngoscope

Orotracheal intubation

Sponsors

Glostrup University Hospital, Copenhagen
Lead SponsorOTHER

Study design

Allocation
RANDOMIZED
Intervention model
PARALLEL
Primary purpose
TREATMENT
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
18 Years to 60 Years
Healthy volunteers
No

Inclusion criteria

* Approved for elective bariatric surgery at Glostrup University Hospital, Copenhagen. * Body Mass Index at least 35 kg/m2 * Written informed consent to participate

Exclusion criteria

* Mental illness * Abuse of alcohol or other substances * Previous difficult tracheal intubation * Considered non-eligible for safety-reasons by the anesthetist in charge

Design outcomes

Primary

MeasureTime frame
Time to intubateMeasured during intubation (seconds)

Secondary

MeasureTime frame
Lowest arterial oxygen saturation during intubationMeasured during intubation (seconds)
Subjective difficulty of intubationMeasured during intubation (seconds)
Cormack-Lehane ScoreMeasured during intubation (seconds)
Number of intubation attemptsMeasured during intubation (seconds)
Dental injuryMeasured during intubation (seconds)
Post-procedure sore throatOne hour post-operative
Post-procedure hoarseness of voiceOne hour post-operative
Airway mucosal traumaMeasured during intubation (seconds)

Countries

Denmark

Outcome results

None listed