Skip to content

Prospective Study for Safety and Efficacy of InSpace™ in Rotator Cuff Tear Subjects

One-arm, International, Multi-center With Competitive Recruitment, Prospective Study to Assess the Safety and Efficacy of OrthoSpace's InSpace™ in Rotator Cuff Tear Subjects Scheduled for Surgery of the Rotator Cuff

Status
Completed
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT00916994
Enrollment
58
Registered
2009-06-10
Start date
2009-07-31
Completion date
2014-06-30
Last updated
2015-03-11

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Rotator Cuff Tear

Keywords

Rotator Cuff Tear

Brief summary

Title: One-arm, international, multi-center with competitive recruitment, prospective study to assess the safety and efficacy of OrthoSpace's InSpace™ in rotator cuff tear subjects scheduled for surgery of the rotator cuff - A pivotal study Device: OrthoSpace's Biodegradable Implanted Balloon (InSpace) Study population: Rotator Cuff tear subjects scheduled for arthroscopy. Number of subjects: Up to 70 subject for data analysis. Number of sites: At least 4 sites in Israel. Main Inclusion criteria: Informed consent, diagnosed with Rotator Cuff tear. Main Exclusion criteria: Former surgery on affected shoulder, sever illness, significant shoulder co morbidities. Follow up period: 12 months. Visits at hospital before discharge at 1-2 days post implantation, 7-10 days post implantation, 3 weeks post implantation, 6 weeks post implantation, 3,6 and 12 months post implantation. Primary goal: To assess the safety of the SpaceGuard in Rotator Cuff tear subjects. Secondary goals: To assess the effectiveness of the SpaceGuard in the study population. The effectiveness will be assessed by terms of good positioning of the SpaceGuard and subsequent follow-up non migration, surgeon satisfaction, pain relief and time to pain relief, Range of Motion (ROM) and time to ROM with the SpaceGuard. Primary end point: Serious Adverse Event rate related to the device and/or system complication. Secondary end points: Surgeon dissatisfaction following the deployment of SpaceGuard, migration of the balloon shown by ultrasound/ X-ray/MRI at relevant follow-up visits, lost of ROM and pain enhancement.

Detailed description

The OrthoSpace's InSpace™ biodegradable sub-acromial spacer (balloon) will be inserted at the end of the routine arthroscopy between the humerus head and the acromion.

Interventions

DEVICESpaceGuard Balloon

Positioning of the balloon into the subacromial space between the humerus head and the acromion

Sponsors

OrthoSpace Ltd.
Lead SponsorINDUSTRY

Study design

Allocation
NON_RANDOMIZED
Intervention model
SINGLE_GROUP
Primary purpose
TREATMENT
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

1. Age 18 or older. 2. Diagnosed with Rotator Cuff tear and are scheduled for surgery. 3. X-Ray of treated shoulder with no unrelated pathology and imaging (ultrasound or MRI) showing Rotator Cuff tear. 4. Persistent pain and functional disability for at least 4 months. 5. Documented failure of conservative treatment. 6. Blood work up to two weeks before implantation as follow: * Normal CBC * Normal electrolytes (potassium, chloride, phosphorous, sodium) * Absolute neutrophil count (ANC) ≥ 1,800 cells/mm3 * Platelets ≥ 100,000 cells/mm3 * Hemoglobin ≥ 10.0 g/dl * Adequate renal function, with serum creatinine ≤ 2.0 mg/dl * Adequate liver function, with serum bilirubin \< 2.0 mg/dl * Adequate liver function with SGOT/SGPT \< 2.5 x the upper normal limit * Normal values of the PT, PTT and INR tests 7. Negative for HIV and Hepatitis B or C 8. Mentally and physically able to fully comply with this protocol including adhering to follow-up schedule and requirements 9. For Woman of Child Bearing Potential (WOCBP), negative pregnancy test and willingness to use birth control during the study. 10. Singed Informed Consent Form.

Exclusion criteria

1. Evidence of significant osteoarthritis or cartilage damage in the shoulder. 2. Evidence of glenohumeral instability. 3. Previous surgeries of the shoulder . 4. Evidence of major joint trauma, infection, or necrosis in the shoulder. 5. Patients unable to provide informed consent due to language barrier or mental status. 6. Patients with a major medical condition that would affect quality of life and influence the results of the study (Including, but not limited to HIV, hepatitis, active malignancy in the past 5 years, transmural MI, CVA and other impaired neurological status, CHF or unstable angina in the past 6 months). 7. Patients unwilling to be followed for the duration of the study. 8. Acute infection requiring intravenous antibiotics at the time of screening. 9. Other shoulder pain of unknown etiology. 10. Paget's disease, osteomalacia or any other metabolic bone disease. 11. Severe diabetes mellitus requiring daily insulin management. 12. Bleeding disorders. 13. Known cognitive disorder. 14. Concurrent participation in any other clinical study. 15. Physician objection. 16. Subjects with sign of cervical root irritation. 17. Chronic lung disease 18. Trauma subjects 19. For WOCBP, a positive pregnancy test.

Design outcomes

Primary

MeasureTime frame
The study's primary goal is to assess the safety of the SpaceGuard and implantation procedure, in the study population. Safety of the SpaceGuard will be assessed by reporting system related adverse events.12-36 months follow-up

Countries

Israel

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026