Skip to content

Set up for in-Vivo Measurement of Dynamic Intraocular Pressure (IOP)

In Vivo Evaluation of Dynamic IOP Measuring Device During Phacoemulsifcation: A Prospective Randomised Clinical Trial

Status
Completed
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT00856141
Enrollment
20
Registered
2009-03-05
Start date
2006-01-31
Completion date
2006-05-31
Last updated
2009-03-05

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Intraocular Pressure

Keywords

IOP measurement, IOP fluctuation, in-vivo IOP measuring device, intraocular pressure measurement

Brief summary

In this modern era, surgeons prefer to perform emulsification through small micro incisions. To accomplish this safely, surgeons raise irrigation bottle heights or use forced infusion systems.We believe that this sustained rise in the IOP during micro-incision phacoemulsification for a substantial period could be detrimental to the ocular structures. Therefore, intra-operative IOP pertaining to micro-incision cataract surgery is an emerging concern. Conventional systems for measuring IOP generate an isolated graph of continuous pressure recording. Interpretation of the IOP fluctuations from these graphs requires a two step superimposition approach to characterize the IOP changes.

Detailed description

The aim of the present study was to describe a new setup for intra-operative monitoring of IOP in a clinical setting and validate it by correlating IOP differences arising with different phacoemulsification parameters in eyes undergoing microincision coaxial phacoemulsification.

Interventions

DEVICEphacoemulsifcation

A sensor (Blumenthal cannula) connected to a transducer, a signal amplifier, an IOP recording device, and a display unit

Sponsors

Iladevi Cataract and IOL Research Center
Lead SponsorOTHER

Study design

Allocation
RANDOMIZED
Intervention model
PARALLEL
Primary purpose
DIAGNOSTIC
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
50 Years to 70 Years
Healthy volunteers
Yes

Inclusion criteria

* patients undergoing phacoemulsification for uncomplicated senile cataracts * Cataracts from grade 1 to 3

Exclusion criteria

* presence of glaucoma, * diabetic retinopathy, * retinal vascular disease, * high myopia (defined as AL \> 25mm), * uveitis, * previous ocular trauma or surgery

Design outcomes

Primary

MeasureTime frame
IOP fluctuation during each phase of surgeryintra-operative

Secondary

MeasureTime frame
comparison of IOP fluctuations between high and low parameters groupintra-operative

Countries

India

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026