Skip to content

Efficacy of On Line Telematic Spirometry

Efficacy of On Line Telematic Spirometry

Status
Completed
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT00844116
Enrollment
226
Registered
2009-02-13
Start date
2009-01-31
Completion date
2011-12-31
Last updated
2012-05-16

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Chronic Obstructive Pulmonary Disease

Keywords

COPD, spirometry, Telematic spirometry

Brief summary

The investigators aim to demonstrate that spirometry performed on line with a technician in a remote place from the patient has the same efficacy as the one performed personally. As a previous study the investigators analyzed the inter-observer agreement between two pulmonary function technicians from both centers taking part in the study: San Pedro de Alcántara Hospital (Cáceres) and Carlos III hospital (Madrid). The main study will be broad (226 patients derivates from primary care to pneumology consultation), prospective, aleatorized, crossed, blind and controlled. The patients will be aleatorized in two groups: 1) personal spirometry: performed in a conventional way; 2) telematic spirometry: performed remotely on line. The same pulmonary function technician, who will carry out the spirometries personally, will be located in a nearly room. The technician will control the computer office and the spirometer software in the patients's room with another computer. By means of teleconference, the technician will indicate the patient to start the maneuver. After 20 minutes from the end of the first spirometry, the patients will complete the protocol of the following group. The mean values of FVC, FEV1 and FEV1/FVC, the mean time of spirometry performance, the mean number of spirometric maneuvers performed, are compared between both groups by t proof for paired data. The comparison of the percentage of proofs with non acceptability or reproducibility criteria will be made by X2 test. The analysis will be made blindly. The inter-observer and intra-observer agreement will be evaluated by analysis of intraclass correlation for FVC and FEV1 values.

Interventions

DEVICEspirometry

Conventional and telematic spirometry

Sponsors

Sociedad Española de Neumología y Cirugía Torácica
Lead SponsorOTHER

Study design

Allocation
RANDOMIZED
Intervention model
CROSSOVER
Primary purpose
HEALTH_SERVICES_RESEARCH
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
14 Years to 70 Years
Healthy volunteers
No

Inclusion criteria

* Age between 14 and 70 years. * Patients referred for pulmonary consultation from primary care center.

Exclusion criteria

* Psychophysical incapacity to performed spirometry. * Informed consent not obtained.

Design outcomes

Primary

MeasureTime frame
The spirometry performed on line with a technician in a remote place from the patient has the same efficacy as the one performed personally and FEV1 and FVCat the end of the study

Secondary

MeasureTime frame
Nº total test feasible Nº total of test Percentage of cases excluded(dropouts) for failure to obstain three acceptable and two reproducibles testat the end of the study

Countries

Spain

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026