Skip to content

A Clinical Evaluation of Everolimus Eluting Coronary Stents in the Treatment of Patients With ST-segment Elevation Myocardial Infarction: EXAMINATION Study

A Clinical Evaluation of Everolimus Eluting Coronary Stents in the Treatment of Patients With ST-segment Elevation Myocardial Infarction.EXAMINATION Study

Status
Completed
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT00828087
Enrollment
1504
Registered
2009-01-23
Start date
2008-12-31
Completion date
2015-05-31
Last updated
2015-05-19

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Myocardial Infarction

Keywords

acute myocardial infarction, primary percutaneous coronary intervention, drug-eluting stent

Brief summary

This study is a prospective, randomized controlled, single blind, two-arm, multi center clinical evaluation. A total of 1500 patients will be enrolled in the study. Patient randomization will be to one of the two treatment arms: Everolimus arm or Non drug eluting stent arm. The objective of this study is to assess the safety and performance of the Everolimus Eluting Coronary Stent System versus a modified cobalt chromium balloon expandable stent in the setting of primary percutaneous coronary intervention for treatment of patients presenting with ST-segment elevation myocardial infarction.

Detailed description

Primary PCI, with or without stenting, has been shown to result in superior long-term outcome when compared to thrombolytic therapy in patients with acute myocardial infarction (MI). Recently, several studies showed that both sirolimus- and paclitaxel-eluting stents are more effective in reducing restenosis and the frequency of repeat interventions than bare metal stents, which rapidly resulted in an unrestricted use of drug-eluting stents, also in patients with ST segment elevation MI (STEMI). , , , Shortly after the introduction of the sirolimus-eluting stent in April 2002 the first studies appeared, hypothesizing that the therapeutic range of sirolimus-eluting stents could be extended to patients presenting with MI. When compared to bare metal stents, sirolimus-eluting stents were associated with less restenosis and target vessel revascularization (TVR) up until one year of follow-up. , At present, it is unclear whether this also holds for paclitaxel-eluting stents.4, Everolimus is a sirolimus analogue, an effective anti-proliferative agent that inhibits growth factor-stimulated cell proliferation by causing cell cycle arrest in the late G1 stage in the cell cycle. The objective of this study is to assess the safety and performance of the Everolimus Eluting Coronary Stent System versus a modified cobalt chromium balloon expandable stent in the setting of primary percutaneous coronary intervention for treatment of patients presenting with ST-segment elevation myocardial infarction. This study is a prospective, randomized controlled, single blind, two-arm, multi center clinical evaluation. A total of 1500 patients will be enrolled in the study. The primary endpoint is the combined endpoint of Composite endpoint of all-cause death, any myocardial infarction and any revascularization at 1 year (patient oriented endpoint suggested by the ARC definitions). The following secondary endpoints will be examined: * All cause and cardiac mortality at 1 year and yearly up to 5 years. * Recurrent myocardial infarction at 1 year and yearly up to 5 years. * Target lesion revascularization at 1 year and yearly up to 5 years. * Target vessel revascularization at 1 year and yearly up to 5 years. * Stent thrombosis (according to the new definitions proposed by the Academic Research Consortium) at 1 year and yearly up to 5 years. * Clinical device success * Clinical procedure success. * Major and minor bleeding at 1 year and yearly up to 5 years.

Interventions

Everolimus Eluting Coronary Stent System (Everolimus Arm) implantation

DEVICEcobalt chromium balloon expandable stent ( non drug eluting stent Arm)

cobalt chromium balloon expandable stent ( non drug eluting stent Arm)implantation

Sponsors

Spanish Society of Cardiology
Lead SponsorOTHER

Study design

Allocation
RANDOMIZED
Intervention model
PARALLEL
Primary purpose
TREATMENT
Masking
SINGLE (Subject)

Eligibility

Sex/Gender
ALL
Healthy volunteers
No

Inclusion criteria

* Patients presenting with a ST-elevation myocardial infarction who must meet at least one of the following criteria * Patients presenting with a ST-elevation myocardial infarction \<12 hours after onset of symptoms who are treated with primary angioplasty + stent implantation * Cardiogenic shock. * Rescue PCI after failed thrombolysis. * PCI indicated early (\<24h) after effective thrombolysis following current ESC guidelines. * Patients presenting late (latecomers) with ST-elevation myocardial infarction (\>12h-48h) after the onset of symptoms. * Written informed consent. * The patient or his/her family (in the event the patient can not be clinically available) accept clinical controls. Angiographic: * Vessel size has to range between 2.25-4.0 mm by visual estimation to allow the implantation of currently available stents.

Exclusion criteria

* Age \< 18 years. * Pregnancy or breastfeeding. * Known intolerance to aspirin, clopidogrel, heparin, stainless steel, Everolimus, contrast material. * Patients with absolute indication of being chronic treated with acenocoumarol * Myocardial infarction due to a previously implanted stent thrombosis * Patients with myocardial infarction that will require elective surgical coronary revascularisation within a 1 year period (example: inferior MI with severe disease in left main with surgical indication).

Design outcomes

Primary

MeasureTime frame
Composite endpoint of all-cause death, any myocardial infarction and any revascularization at 1 year.1 year

Secondary

MeasureTime frameDescription
Recurrent myocardial infarctionat 1 year and yearly up to 5 years
Target lesion revascularizationat 1 year and yearly up to 5 years
Target vessel revascularizationat 1 year and yearly up to 5 years
All cause and cardiac mortalityat 1 year and yearly up to 5 years
Clinical device successProcedure momentSuccessful delivery and deployment of the first inserted stent and a final diameter stenosis after stenting ≤ 50% by QCA or visual assessment.
Clinical procedure successprocedure momentSuccessful delivery and deployment of study stent in the target lesion and successful removal of the stent delivery system with a final diameter stenosis after stenting ≤ 50% by QCA or visual assessment without the occurrence of serious cardiac events important for ischemia during hospitalization, with a maximum of seven days after the initial procedure.
Major and minor bleedingat 1 year and yearly up to 5 years
Stent thrombosisat 1 year and yearly up to 5 years

Countries

Italy, Netherlands, Spain

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Mar 27, 2026