Skip to content

Effects of Epidural Lidocaine on the Pharmacokinetic and Pharmacodynamic Profiles of DepoDur® After Cesarean Delivery

A Study to Evaluate the Effects of Epidural Lidocaine Administration on the Pharmacokinetic and Pharmacodynamic Profiles of DepoDur® (Morphine Sulfate Extended-release Injection) in Patients Undergoing Cesarean Delivery

Status
Completed
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT00804609
Enrollment
30
Registered
2008-12-09
Start date
2008-09-30
Completion date
2010-12-31
Last updated
2017-10-12

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Epidural Analgesia, Obstetric

Brief summary

To evaluate the levels of morphine in a patient's blood when morphine is given into the epidural space in the form of DepoDur® either alone or following a dose of lidocaine also given in the epidural space.

Detailed description

To evaluate the levels of morphine in a patient's blood when morphine is given into the epidural space in the form of DepoDur® either alone or following a dose of lidocaine also given in the epidural space. Specifically, we are looking at pregnant women undergoing cesarean delivery who will be receiving these medications. A secondary objective is to evaluate how well DepoDur® works for pain control, as well as its safety, when it is given either alone or following a dose of epidural lidocaine.

Interventions

DRUGDepoDur following epidural lidocaine

All participant underwent cesarean delivery. An epidural top-up anesthetic consisting of 2% lidocaine with epinephrine 1:200,000 and sodium bicarbonate (1 meq per 10 mL lidocaine) was given. The lidocaine solution was administered in 5 mL increments every 2.5 minutes until a T6 sensory level to touch was attained. Patients also received a 100 mcg dose of fentanyl epidurally after the lidocaine solution had been administered. Provided delivery had occurred at least 60 minutes after the initial lidocaine administration, patients received EREM 8 mg (DepoDur™) administered through the epidural catheter. A 2 mL epidural saline flush was administered before and after drug administration.

DRUGDepoDur following spinal anesthetic

Participants underwent an elective cesarean delivery with a combined spinal/epidural. All patients received 12 mg hyperbaric bupivacaine with 20 mcg fentanyl administered intrathecally. No local anesthetic was administered through the catheter. The combined spinal-epidural was performed at the L2/L3 or L3/L4 interspace and the intrathecal dose was injected over 5-10 s. A multiple orifice epidural catheter was threaded 5 cm into the epidural space. Provided delivery had occurred 60 minutes after the intrathecal dose patients received EREM 8 mg (DepoDur™) through the epidural catheter. A 2 mL epidural saline flush was administered before and after drug.

Sponsors

Stanford University
Lead SponsorOTHER

Study design

Allocation
RANDOMIZED
Intervention model
FACTORIAL
Primary purpose
TREATMENT
Masking
QUADRUPLE (Subject, Caregiver, Investigator, Outcomes Assessor)

Eligibility

Sex/Gender
FEMALE
Age
18 Years to 40 Years
Healthy volunteers
No

Inclusion criteria

Inclusion criteria will include healthy parturients between the ages of 18 and 40 who have American Society of Anesthesiologists physical status I or II, have an uncomplicated, singleton, term pregnancy, and are scheduled to undergo cesarean delivery.

Design outcomes

Primary

MeasureTime frameDescription
Maximum Plasma Concentration (Cmax) of Extended Release Epidural Morphine (EREM)a plasma sample at 0, 5, 10, 15, and 30 minutes, and 1, 4, 8, 12, 24, 36, 48, and 72 hours post-doseThe primary end point was to evaluate the pharmacokinetic profiles of EREM after either no epidural lidocaine or after an epidural lidocaine top-up for cesarean delivery.

Countries

United States

Participant flow

Recruitment details

30 patients enrolled at Stanford clinics

Pre-assignment details

The patients were divided into 2 groups: group E (epidural) consisted of patients undergoing elective cesarean delivery or undergoing nonelective cesarean delivery during labor. Group SE (Spinal-Epidural) consisted of patients undergoing an elective cesarean delivery. Patients received an anesthetic consisting of a combined spinal-epidural.

Participants by arm

ArmCount
Epidural DepoDur Following Epidural Lidocaine Administration
Epidural DepoDur was administered 60 minutes after an epidural Lidocaine top-up for surgical anesthetic in cesarean section patients. DepoDur: All participant underwent cesarean delivery. An epidural top-up anesthetic consisting of 2% lidocaine with epinephrine 1:200,000 and sodium bicarbonate (1 meq per 10 mL lidocaine) was given. The lidocaine solution was administered in 5 mL increments every 2.5 minutes until a T6 sensory level to touch was attained. Patients also received a 100 mcg dose of fentanyl epidurally after the lidocaine solution had been administered. Provided delivery had occurred at least 60 minutes after the initial lidocaine administration, patients received EREM 8 mg (DepoDur™) administered through the epidural catheter. A 2 mL epidural saline flush was administered before and after drug administration.
15
Epidural DepoDur Following Spinal Anesthetic
Epidural DepoDur was administered 60 minutes after a standard spinal anesthetic. No prior epidural local anesthetic was used prior to DepoDur in this group assignment. DepoDur: Participants underwent an elective cesarean delivery with a combined spinal/epidural. All patients received 12 mg hyperbaric bupivacaine with 20 mcg fentanyl administered intrathecally. No local anesthetic was administered through the catheter. The combined spinal-epidural was performed at the L2/L3 or L3/L4 interspace and the intrathecal dose was injected over 5-10 s. A multiple orifice epidural catheter was threaded 5 cm into the epidural space. Provided delivery had occurred 60 minutes after the intrathecal dose patients received EREM 8 mg (DepoDur™) through the epidural catheter. A 2 mL epidural saline flush was administered before and after drug.
15
Total30

Baseline characteristics

CharacteristicEpidural DepoDur Following Epidural Lidocaine AdministrationEpidural DepoDur Following Spinal AnestheticTotal
Age, Categorical
<=18 years
0 Participants0 Participants0 Participants
Age, Categorical
>=65 years
0 Participants0 Participants0 Participants
Age, Categorical
Between 18 and 65 years
15 Participants15 Participants30 Participants
Age, Continuous32 years
STANDARD_DEVIATION 5
36 years
STANDARD_DEVIATION 3
34 years
STANDARD_DEVIATION 4
Region of Enrollment
United States
15 participants15 participants30 participants
Sex: Female, Male
Female
15 Participants15 Participants30 Participants
Sex: Female, Male
Male
0 Participants0 Participants0 Participants

Adverse events

Event typeEG000
affected / at risk
EG001
affected / at risk
deaths
Total, all-cause mortality
— / —— / —
other
Total, other adverse events
11 / 151 / 14
serious
Total, serious adverse events
0 / 00 / 0

Outcome results

Primary

Maximum Plasma Concentration (Cmax) of Extended Release Epidural Morphine (EREM)

The primary end point was to evaluate the pharmacokinetic profiles of EREM after either no epidural lidocaine or after an epidural lidocaine top-up for cesarean delivery.

Time frame: a plasma sample at 0, 5, 10, 15, and 30 minutes, and 1, 4, 8, 12, 24, 36, 48, and 72 hours post-dose

ArmMeasureValue (MEAN)Dispersion
Epidural DepoDur Following Epidural Lidocaine AdministrationMaximum Plasma Concentration (Cmax) of Extended Release Epidural Morphine (EREM)11.1 ng/mLStandard Deviation 4.9
Epidural DepoDur Following Spinal AnestheticMaximum Plasma Concentration (Cmax) of Extended Release Epidural Morphine (EREM)8.3 ng/mLStandard Deviation 7.1

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026