Skip to content

A Safety and Tolerability Study of Intracerebroventricular Administration of sNN0029 to Patients With Amyotrophic Lateral Sclerosis

A Double-blind, Randomised, Parallel Group Safety and Tolerability Study of Intracerebroventricular Administration of sNN0029 to Patients With Amyotrophic Lateral Sclerosis, Using an Implanted Catheter and SynchroMed® II Pump

Status
Completed
Phases
Phase 1Phase 2
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT00800501
Enrollment
18
Registered
2008-12-02
Start date
2008-12-31
Completion date
2011-06-30
Last updated
2011-12-06

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Amyotrophic Lateral Sclerosis

Keywords

ALS, VEGF165, Safety, Intracerebroventricular, Infusion, Implantable

Brief summary

This study is conducted to evaluate the safety and tolerability of the drug product sNN0029, containing the growth factor VEGF165, when administered directly into one of the fluid filled cavities in the brain using an implanted catheter and an implanted SynchroMed® II pump. Patients with Amyotrophic Lateral Sclerosis will be enrolled.

Detailed description

Vascular endothelial growth factor (VEGF) is an endogenous human protein fundamental to the development of the vascular and nervous systems in the body. A role for VEGF in ALS has been suggested from observations in animal models of the disease as well as observations of a dysregulation of VEGF production in patients with ALS. NeuroNova intends to investigate whether intracerebroventricular administration of VEGF165 in the form of the drug product sNN029 can improve motor function and prolong survival in patients with ALS, and in this first study the safety and tolerability of treatment for 3 months will be evaluated. Assessments will include: * Electrocardiograms, vital signs and clinical laboratory tests * Adverse events and withdrawals related to adverse events * Possible pathological changes in the brain, spinal cord or retina identified through magnetic resonance imaging and funduscopy * Possible signs of intracranial bleeding or loss of blood-brain-barrier integrity through measurements of bilirubin and albumin levels in cerebrospinal fluid collected through lumbar and cervical puncture * Device performance as characterized by catheter tip placement (determined by imaging) and infusion accuracy (pump residual volume) The secondary objective of this study is: * To explore the effect of ICV administration of sNN0029 on the time course of Amyotrophic Lateral Sclerosis related parameters including: * Disease activity as measured by Amyotrophic Lateral Sclerosis Functional Rating Scale * Quality of life as measured by the EQ-5D rating scale * To explore the levels of VEGF165 in cerebrospinal fluid collected through lumbar and cervical puncture.

Interventions

Continuous ICV infusion at one of three dose levels

DRUGPlacebo

Continuous ICV infusion

Sponsors

Medtronic
CollaboratorINDUSTRY
ICON Clinical Research
CollaboratorINDUSTRY
Newron Sweden AB
Lead SponsorINDUSTRY

Study design

Allocation
RANDOMIZED
Intervention model
PARALLEL
Primary purpose
TREATMENT
Masking
QUADRUPLE (Subject, Caregiver, Investigator, Outcomes Assessor)

Eligibility

Sex/Gender
ALL
Age
18 Years to 75 Years
Healthy volunteers
No

Inclusion criteria

1. Clinical diagnosis of ALS classified as definite, or probable with or without additional laboratory evidence, according to the revised WFN El Escorial criteria. 2. Age 18 to 75 years inclusive. 3. If patients are being treated with riluzole, they must have been on a stable dose for at least 30 days. 4. Ophthalmological examination at screening with normal findings regarding vascular structure and function. 5. MRI/magnetic resonance angiography (MRA) examination of the brain and cervical spinal cord at screening with no findings of tumors or potential sources of pathological bleedings, or abnormality that may interfere with the assessments of safety or efficacy or that would, in the judgement of the investigator, represent a surgical risk to the subject. 6. Values of coagulation parameters including platelet count, normalized prothrombin complex (PK-INR), activated partial thromboplastin time (APTT) within normal ranges. 7. Patient is medically able to undergo the surgery required for stereotactic implantation of the catheter and infusion pump. 8. Patient has been given written and verbal information, has had the opportunity to ask questions about the study, and understands the time and procedural commitments. 9. Patient has given signed consent (written) to participate in the study. In the event that a patient who gives oral informed consent is not physically able to sign the informed consent form (ICF) due to disease progression, a witness may sign the ICF on the patient's behalf.

Exclusion criteria

1. Impaired respiratory function judged to pose a risk to the patient during anaesthesia for the device implantation. 2. Hypertension defined as blood pressure \>160 mmHg systolic or \>90 mmHg diastolic. 3. Diagnosis of diabetes mellitus. 4. Proliferative retinopathy. 5. Non-proliferative retinopathy of moderate severity or higher. 6. Concurrent clinically significant dementia as determined by the investigator. 7. Concurrent clinically significant depression as determined by the investigator. 8. History of structural brain disease other than ALS, including tumours and hyperplasia. 9. Any disorder that precludes a surgical procedure (e.g., signs of sepsis or inadequately treated infection), alters wound healing (e.g., including bleeding disorders), or renders chronic ICV delivery or device implants medically unsuitable. 10. Presence of risk for increased or uncontrolled bleeding and/or risk of bleeding that is not managed optimally. Physicians should specifically investigate anatomical factors at or near the implant site (e.g., vascular abnormalities, neoplasms, or other abnormalities), underlying disorders of the coagulation cascade, platelet function, or platelet count (e.g., haemophilia, Von Willebrand's disease, liver disease, or other medical conditions), and the administration of any antiplatelet or anticoagulant medication (e.g., aspirin, Plavix, NSAIDs) in the pre- or perioperative period. Any of those conditions or drugs could place a patient at an increased risk for intraoperative or postoperative bleeding. 11. Presence of an implanted shunt for the drainage of CSF or an implanted CNS catheter. 12. Presence of cardiac pacemakers, spinal cord stimulators, implantable programmable intraspinal drug pumps, or any other device that may interfere or interact with the programmer, without prior approval by Medtronic. 13. Clinically significant abnormalities in hematology or clinical chemistry parameters as assessed by the investigator. 14. Ongoing medical condition that according to the investigator would interfere with the conduct and assessments in the study. Examples are medical disability (e.g., severe degenerative arthritis, compromised nutritional state, peripheral neuropathy) that would interfere with the assessment of safety and efficacy of investigational product or device performance, or would compromise the ability of the subject to undergo study procedures (e.g., MRI), or to give informed consent. 15. Participation in another clinical trial with an investigational drug or device within 3 months prior to Screening visit. 16. For female subjects, ongoing pregnancy or planned pregnancy during the period of treatment with study drug. 17. Breast feeding during the period of treatment with study drug.

Design outcomes

Primary

MeasureTime frame
Safety and tolerability through assessment of adverse events, ECGs, vital signs, clinical laboratory variables, MRI of brain and spinal cord, CSF sampling, and device performance as characterized by catheter tip placement and infusion accuracy.Multiple assessments over 3 months

Secondary

MeasureTime frame
Time course of Amyotrophic Lateral Sclerosis Functional Rating Scale, Quality of life as measured by the EQ-5D rating scaleMultiple assessments over 3 months

Countries

Belgium

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026