Skip to content

A Comparison of Two Urinary Catheters of Different Lengths for Female Use, in Intermittent Catheterization

A Multi Centre, Single-blind, Randomized, Cross-over Study Comparing Two Female Catheters With Different Length in Terms of Residual Urine After Intermittent Catheterization

Status
Completed
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT00799981
Enrollment
60
Registered
2008-12-01
Start date
2008-11-30
Completion date
2009-03-31
Last updated
2021-05-18

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Catheterization

Brief summary

A study comparing a 10 cm catheter with a 7 cm catheter in a group of female patients who, on a routine bases, empty their bladder using urinary catheters, by measuring residual urine after intermittent catheterization.

Detailed description

The study personnel will conduct three bladder scans after each catheterization in order to obtain the mean residual urine volume. Each patient will catheterize herself two times with each product, i.e. a total of four catheterizations. Diagnosis and BMI will be collected at visit 1 to assess whether the residual urine volume differs between these subgroups. The hypothesis that the mean residual volumes were equal when using the 7 and the 10 centimeter catheters was tested by means of the Wilcoxon signed rank test.

Interventions

DEVICEA=SpeediCath Compact 7 cm and B=POBE 10 cm

Catheterization should resemble the daily use as far as possible and at least 2 hours had to pass between 2 catheterizations.The study centre decided whether the subject performed all four catheterizations on one or several days.

Sponsors

Wellspect HealthCare
Lead SponsorINDUSTRY

Study design

Allocation
RANDOMIZED
Intervention model
CROSSOVER
Primary purpose
OTHER
Masking
DOUBLE (Investigator, Outcomes Assessor)

Masking description

The subjects were handed out numbered boxes with the catheter randomised to be used and then cathererisized by herself. The investigator was blinded to which catheter was used.

Intervention model description

The study was designed as a randomised, single blind, cross-over study to eliminate bias. Every subject was catheterisized with both 7 cm and 10 cm long catheters.

Eligibility

Sex/Gender
FEMALE
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* Provision of signed informed consent * Female subjects aged 18 years and over * Experienced users of CIC with a minimum of one month of use * Practice CIC a minimum of 1 time per day * Practice CIC with female catheters with a maximum length of 20 cm * Perform self-catheterization * Sufficient hand function to be able to open and handle catheter packages * Use catheters with Ch 10, 12 or 14

Exclusion criteria

* Pregnancy * Ongoing symptomatic UTI * Involvement in the planning and conduct of the study (applies to both Astra Tech staff or staff at the study site) * Previous enrolment or randomisation of treatment in the present study * Participation in another clinical study during the study period * Severe non-compliance to protocol as judged by the investigator and/or Astra Tech

Design outcomes

Primary

MeasureTime frameDescription
Bladder Scan Measurements of Residual Urine VolumeThree bladder scan measurements were performed immediately after each catheterization and a mean value was calculated. A maximum of 5 minutes were allowed to elapse between catheterization and bladder scan.Measurements were performed with the bladder scan BVI 3000. The primary outcome variable was average residual urine volume (mL) calculated from repetitive bladder scans performed after each catheterization. Three bladder scan measurements were performed immediately after each catheterization and a mean value was calculated.

Secondary

MeasureTime frameDescription
Number of Subjects With a Residual Volume >5mL or ≤5mLThree bladder scan measurements were performed immediately after each catheterization and a mean value was calculated. At least 2 hours had to pass between 2 catheterizations.
Number of Subjects With a Residual Volume >10mL or ≤10mLThree bladder scan measurements were performed immediately after each catheterization and a mean value was calculated. A maximum of 5 minutes were allowed to elapse between catheterization and bladder scan.
Number of Subjects With a Residual Volume >30mL or ≤30mLThree bladder scan measurements were performed immediately after each catheterization and a mean value was calculated. A maximum of 5 minutes were allowed to elapse between catheterization and bladder scan.
Number of Subjects With a Residual Volume >50mL or ≤50mLThree bladder scan measurements were performed immediately after each catheterization and a mean value was calculated. A maximum of 5 minutes were allowed to elapse between catheterization and bladder scan.
Does the Subject's Bladder Feel Completely Empty After Catheterisation (All Subjects)Question asked minutes after catheterization.After each catheterization the study nurse will ask the subject whether it feels as if the bladder is completely emptied or not. 0=No and 1=Yes.

Countries

Sweden

Participant flow

Recruitment details

Each subject eligible for entry into the study was a female using catheters for intermittent self catheterization at least once a day and had done so for the last month. Three centers in Sweden were involved. Four catheterizations, two with each product in a randomized order, were performed at the study centre. Catheterization should resemble the daily use as far as possible.

Participants by arm

ArmCount
Four Catheterizations, Each Subject Was Catheterisized Twice With Each Product in a Randomized Order
A=Coloplast SpeediCath Compact catheter, 7 cm B=Astra Tech POBE catheter, 10 cm 6 arms with the following order of catheters used: AABB ABAB ABBA BAAB BABA BBAA BBAA
60
Total60

Baseline characteristics

CharacteristicFour Catheterizations, Each Subject Was Catheterisized Twice With Each Product in a Randomized Order
Age, Continuous48.20 years
STANDARD_DEVIATION 15.34
BMI24.78 kg/m^2
STANDARD_DEVIATION 4.52
Height163.62 Cm
STANDARD_DEVIATION 7.48
Region of Enrollment
Sweden
60 participants
Sex: Female, Male
Female
60 Participants
Sex: Female, Male
Male
0 Participants
Weight66.53 Kilogramme
STANDARD_DEVIATION 13.98

Adverse events

Event typeEG000
affected / at risk
EG001
affected / at risk
deaths
Total, all-cause mortality
0 / 600 / 60
other
Total, other adverse events
2 / 601 / 60
serious
Total, serious adverse events
0 / 600 / 60

Outcome results

Primary

Bladder Scan Measurements of Residual Urine Volume

Measurements were performed with the bladder scan BVI 3000. The primary outcome variable was average residual urine volume (mL) calculated from repetitive bladder scans performed after each catheterization. Three bladder scan measurements were performed immediately after each catheterization and a mean value was calculated.

Time frame: Three bladder scan measurements were performed immediately after each catheterization and a mean value was calculated. A maximum of 5 minutes were allowed to elapse between catheterization and bladder scan.

Population: All subjects in the investigation

ArmMeasureValue (MEAN)Dispersion
7 cmBladder Scan Measurements of Residual Urine Volume32.74 Residual volume in mLStandard Deviation 41.48
10 cmBladder Scan Measurements of Residual Urine Volume34.78 Residual volume in mLStandard Deviation 38.76
Comparison: The hypothesis that a 10 cm catheter provides equal emptying of the bladder as a 7 cm catheter was tested.p-value: 0.8762Wilcoxon (Mann-Whitney)
Secondary

Does the Subject's Bladder Feel Completely Empty After Catheterisation (All Subjects)

After each catheterization the study nurse will ask the subject whether it feels as if the bladder is completely emptied or not. 0=No and 1=Yes.

Time frame: Question asked minutes after catheterization.

Population: All subjects participating in the investigation.

ArmMeasureGroupValue (MEAN)Dispersion
7 cmDoes the Subject's Bladder Feel Completely Empty After Catheterisation (All Subjects)7 cm0.75 score on a scaleStandard Deviation 0.4
7 cmDoes the Subject's Bladder Feel Completely Empty After Catheterisation (All Subjects)10 cm0.83 score on a scaleStandard Deviation 0.35
7 cmDoes the Subject's Bladder Feel Completely Empty After Catheterisation (All Subjects)7 cm - 10 cm-0.08 score on a scaleStandard Deviation 0.26
Comparison: In the table 0=No and 1=Yes.p-value: 0.0273Wilcoxon (Mann-Whitney)
Secondary

Number of Subjects With a Residual Volume >10mL or ≤10mL

Time frame: Three bladder scan measurements were performed immediately after each catheterization and a mean value was calculated. A maximum of 5 minutes were allowed to elapse between catheterization and bladder scan.

Population: All subjecs participating in the investigation.

ArmMeasureGroupValue (COUNT_OF_PARTICIPANTS)
7 cmNumber of Subjects With a Residual Volume >10mL or ≤10mL>10mL38 Participants
7 cmNumber of Subjects With a Residual Volume >10mL or ≤10mL≤10mL22 Participants
10 cmNumber of Subjects With a Residual Volume >10mL or ≤10mL>10mL37 Participants
10 cmNumber of Subjects With a Residual Volume >10mL or ≤10mL≤10mL23 Participants
p-value: 1McNemar
Secondary

Number of Subjects With a Residual Volume >30mL or ≤30mL

Time frame: Three bladder scan measurements were performed immediately after each catheterization and a mean value was calculated. A maximum of 5 minutes were allowed to elapse between catheterization and bladder scan.

Population: All subjects in the investigation.

ArmMeasureGroupValue (COUNT_OF_PARTICIPANTS)
7 cmNumber of Subjects With a Residual Volume >30mL or ≤30mL>30mL19 Participants
7 cmNumber of Subjects With a Residual Volume >30mL or ≤30mL≤30mL41 Participants
10 cmNumber of Subjects With a Residual Volume >30mL or ≤30mL>30mL26 Participants
10 cmNumber of Subjects With a Residual Volume >30mL or ≤30mL≤30mL34 Participants
Secondary

Number of Subjects With a Residual Volume >50mL or ≤50mL

Time frame: Three bladder scan measurements were performed immediately after each catheterization and a mean value was calculated. A maximum of 5 minutes were allowed to elapse between catheterization and bladder scan.

Population: All subjects participating in the investigation.

ArmMeasureGroupValue (COUNT_OF_PARTICIPANTS)
7 cmNumber of Subjects With a Residual Volume >50mL or ≤50mL>50mL15 Participants
7 cmNumber of Subjects With a Residual Volume >50mL or ≤50mL≤50mL45 Participants
10 cmNumber of Subjects With a Residual Volume >50mL or ≤50mL>50mL16 Participants
10 cmNumber of Subjects With a Residual Volume >50mL or ≤50mL≤50mL44 Participants
Secondary

Number of Subjects With a Residual Volume >5mL or ≤5mL

Time frame: Three bladder scan measurements were performed immediately after each catheterization and a mean value was calculated. At least 2 hours had to pass between 2 catheterizations.

Population: All subjects participating in the investigation.

ArmMeasureCategoryValue (COUNT_OF_PARTICIPANTS)
7 cmNumber of Subjects With a Residual Volume >5mL or ≤5mL> 5 mL42 Participants
7 cmNumber of Subjects With a Residual Volume >5mL or ≤5mL≤ 5 mL18 Participants
10 cmNumber of Subjects With a Residual Volume >5mL or ≤5mL> 5 mL40 Participants
10 cmNumber of Subjects With a Residual Volume >5mL or ≤5mL≤ 5 mL20 Participants
p-value: 0.7905McNemar

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026