Effectiveness and Safety Study of the Next-Generation DexCom™ SEVEN® Continuous Glucose Monitoring System

Effectiveness and Safety Study of the Next-Generation DexCom™ SEVEN® Continuous Glucose Monitoring System

Status
Completed
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT00722241
Enrollment
53
Registered
2008-07-25
Start date
2008-05-31
Completion date
2008-07-31
Last updated
2008-07-25

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Diabetes Mellitus, Type 1, Diabetes Mellitus, Type 2

Keywords

Continuous Glucose Monitoring, Interstitial Fluid, Diabetes Mellitus

Brief summary

The purpose of this study is to evaluate the safety and effectiveness of the next-generation DexCom SEVEN Continuous Glucose Monitoring System (SEVEN.2 System) when worn for up to 7-days by subjects \>18 years-old with diabetes mellitus requiring insulin therapy.

Interventions

None listed

Sponsors

DexCom, Inc.
Lead SponsorINDUSTRY

Study design

Observational model
CASE_ONLY
Time perspective
PROSPECTIVE

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* Age 18 years or older * Have been diagnosed with insulin-requiring diabetes and are on multiple daily injections (MDI) or Continuous Subcutaneous Insulin Infusion (CSII) insulin therapy * Willing not to inject insulin or wear an insulin pump insertion set within 3 inches from the Sensor site during Sensor wear * Willing to use only the blood glucose meter(s) provided to them for self-monitoring of blood glucose (SMBG) during Sensor wear * Willing to participate in one, 8-hour in-clinic session and be willing to take 4 fingersticks per hour and have 4 blood draws per hour for the entire 8-hour duration * Willing to take a minimum of 6 fingersticks per day during home use (2 for calibration purposes, 4 for comparative purposes) * Willing to refrain from the use of acetaminophen during the Sensor insertion period and for at least 24-hours prior to Sensor insertion * Willing not to schedule a magnetic resonance (MRI) scan, computed tomography (CT) scan, or x-ray, for the duration of the study * Able to speak, read, and write English

Exclusion criteria

* Have extensive skin changes/diseases that preclude wearing the Sensor on normal skin (e.g. extensive psoriasis, recent burns or severe sunburn, extensive eczema, extensive scarring, extensive tattoos, dermatitis herpetiformis) at the proposed wear sites * Subjects who have a known allergy to medical-grade adhesives * Are pregnant as demonstrated by a positive pregnancy test within 72 hours of insertion * Have a hematocrit that is less than 30%, or greater than 55% * Current participation in another investigational study protocol (if a subject has recently completed participation in another drug study, the subject must have completed that study at least 30 days prior to being enrolled in this study) * Have any condition that, in the opinion of the Investigator, would interfere with their participation in the trial or pose an excessive risk to study staff handling venous blood samples (e.g., known history of hepatitis B or C)

Design outcomes

Primary

MeasureTime frame
SEVEN.2 System accuracy as compared to Yellow Springs Instrument (YSI) venous blood glucose measurementsDays 1, 4, and 7 of Sensor wear

Countries

United States

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026