Visual Outcomes of Subjects Bilaterally Implanted With ReSTOR Aspheric +4 vs. Tecnis or Acri.LISA

Visual Outcomes of Subjects Bilaterally Implanted With ReSTOR Aspheric +4 vs. Tecnis Multifocal Intraocular Lens (IOL) or Acri.LISA IOL

Status
Completed
Phases
Phase 4
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT00721253
Enrollment
42
Registered
2008-07-24
Start date
2007-07-31
Completion date
2008-10-31
Last updated
2010-03-16

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Cataract

Keywords

ReSTOR

Brief summary

This is a study to compare visual outcomes of subjects bilaterally implanted w/ReSTOR to subjects bilaterally implanted with the Tecnis Multifocal Intraocular Lens (IOL) or Acri.LISA IOL

Interventions

DEVICEReSTOR

Implantation of the ReSTOR Aspheric +4 (SN6AD3) multifocal intraocular lens (IOL)

DEVICETecnis

Implantation with the Tecnis multifocal (ZM900) intraocular lens (IOL)

DEVICEAcri.LISA

Implantation with the Acri.LISA 366D multifocal intraocular lens (IOL)

Sponsors

Alcon Research
Lead SponsorINDUSTRY

Study design

Allocation
RANDOMIZED
Intervention model
PARALLEL
Primary purpose
TREATMENT
Masking
SINGLE (Subject)

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
Yes

Inclusion criteria

* Diagnosed with cataracts

Exclusion criteria

* Preexisting condition likely to confound results; 1 D astigmatism by preoperative K-readings

Design outcomes

Primary

MeasureTime frameDescription
Uncorrected Visual Acuity (UCVA) at Distance, Near and Intermediate6 monthsUncorrected Visual Acuity (UCVA) at distance, near and intermediate, measured in logMAR. LogMAR is the logarithm of the minimum angle of resolution. It is a unit of measure for visual acuity (VA). A lower logMAR value indicates better visual acuity.

Secondary

MeasureTime frameDescription
Contrast Sensitivity6 monthsContrast sensitivity is the measurement of one's ability to detect slight changes in luminance before it becomes indistinguishable. It is measured in logarithmic units by means of an illuminated box, the CSV 1000 by Vector Vision. A higher value for the logarithmic units translates to better contrast sensitivity.
Defocus Curve6 months post-operativeDefocus cureve. A defocus curve is created by multiple measurements of one's visual acuity at different spherical powers. Visual Acuity (VA) is measured in logMAR. LogMAR is the logarithm of the minimum angle of resolution. A lower logMAR value indicates better visual acuity.

Countries

United States

Participant flow

Recruitment details

Subjects 18 years or older of either sex and any race; bilateral diagnosis of cataracts. There were no patients that received implantation of the Tecnis Multifocal lens.

Pre-assignment details

Subject eligibility was determined at the pre-operative visit.

Participants by arm

ArmCount
ReSTOR Aspheric +4
Bilateral implantation of ACRYSOF ReSTOR Aspheric +4 Model SN6AD3
20
Acri LISA IOL
Bilateral Implantation of Meditec Acri.LISA Intraocular Lens (IOL) Model 366D
22
Total42

Baseline characteristics

CharacteristicReSTOR Aspheric +4Acri LISA IOLTotal
Age, Categorical
<=18 years
0 Participants0 Participants0 Participants
Age, Categorical
>=65 years
8 Participants1 Participants9 Participants
Age, Categorical
Between 18 and 65 years
12 Participants21 Participants33 Participants
Sex: Female, Male
Female
12 Participants15 Participants27 Participants
Sex: Female, Male
Male
8 Participants7 Participants15 Participants

Adverse events

Event typeEG000
affected / at risk
EG001
affected / at risk
deaths
Total, all-cause mortality
— / —— / —
other
Total, other adverse events
0 / 200 / 22
serious
Total, serious adverse events
0 / 200 / 22

Outcome results

Primary

Uncorrected Visual Acuity (UCVA) at Distance, Near and Intermediate

Uncorrected Visual Acuity (UCVA) at distance, near and intermediate, measured in logMAR. LogMAR is the logarithm of the minimum angle of resolution. It is a unit of measure for visual acuity (VA). A lower logMAR value indicates better visual acuity.

Time frame: 6 months

ArmMeasureGroupValue (MEAN)Dispersion
ReSTOR Aspheric +4Uncorrected Visual Acuity (UCVA) at Distance, Near and IntermediateUCVA 80 cm0.20 logMARStandard Deviation 0.14
ReSTOR Aspheric +4Uncorrected Visual Acuity (UCVA) at Distance, Near and IntermediateUCVA 4 m0.02 logMARStandard Deviation 0.13
ReSTOR Aspheric +4Uncorrected Visual Acuity (UCVA) at Distance, Near and IntermediateUCVA 60 cm0.21 logMARStandard Deviation 0.14
ReSTOR Aspheric +4Uncorrected Visual Acuity (UCVA) at Distance, Near and IntermediateUCVA Near at 40 cm-0.04 logMARStandard Deviation 0.18
Acri LISA IOLUncorrected Visual Acuity (UCVA) at Distance, Near and IntermediateUCVA Near at 40 cm-0.05 logMARStandard Deviation 0.07
Acri LISA IOLUncorrected Visual Acuity (UCVA) at Distance, Near and IntermediateUCVA 60 cm0.19 logMARStandard Deviation 0.14
Acri LISA IOLUncorrected Visual Acuity (UCVA) at Distance, Near and IntermediateUCVA 4 m0.01 logMARStandard Deviation 0.18
Acri LISA IOLUncorrected Visual Acuity (UCVA) at Distance, Near and IntermediateUCVA 80 cm0.20 logMARStandard Deviation 0.15
Secondary

Contrast Sensitivity

Contrast sensitivity is the measurement of one's ability to detect slight changes in luminance before it becomes indistinguishable. It is measured in logarithmic units by means of an illuminated box, the CSV 1000 by Vector Vision. A higher value for the logarithmic units translates to better contrast sensitivity.

Time frame: 6 months

ArmMeasureGroupValue (MEAN)Dispersion
ReSTOR Aspheric +4Contrast SensitivityContrast Sensitivity 18 cpd1.02 log unitsStandard Deviation 0.42
ReSTOR Aspheric +4Contrast SensitivityMesopic Conditions, 12 cpd1.11 log unitsStandard Deviation 0.36
ReSTOR Aspheric +4Contrast SensitivityContrast Sensitivity 3 cpd1.98 log unitsStandard Deviation 0.23
ReSTOR Aspheric +4Contrast SensitivityMesopic Conditions, 18 cpd0.54 log unitsStandard Deviation 0.26
ReSTOR Aspheric +4Contrast SensitivityMesopic Conditions, 1.5 cpd1.87 log unitsStandard Deviation 0.21
ReSTOR Aspheric +4Contrast SensitivityMesopic Conditions w/glare, 1.5 cpd1.56 log unitsStandard Deviation 0.37
ReSTOR Aspheric +4Contrast SensitivityMesopic Conditions w/glare, 6 cpd1.31 log unitsStandard Deviation 0.34
ReSTOR Aspheric +4Contrast SensitivityContrast Sensitivity 12 cpd1.57 log unitsStandard Deviation 0.31
ReSTOR Aspheric +4Contrast SensitivityMesopic Conditions, 3 cpd1.91 log unitsStandard Deviation 0.22
ReSTOR Aspheric +4Contrast SensitivityMesopic Conditions w/glare, 3 cpd1.56 log unitsStandard Deviation 0.39
ReSTOR Aspheric +4Contrast SensitivityContrast Sensitivity 6 cpd1.94 log unitsStandard Deviation 0.24
ReSTOR Aspheric +4Contrast SensitivityMesopic Conditions w/glare, 12 cpd0.72 log unitsStandard Deviation 0.26
ReSTOR Aspheric +4Contrast SensitivityMesopic Conditions, 6 cpd1.68 log unitsStandard Deviation 0.23
ReSTOR Aspheric +4Contrast SensitivityMesopic Conditions w/glare, 18 cpd0.34 log unitsStandard Deviation 0.13
ReSTOR Aspheric +4Contrast SensitivityContrast Sensitivity 1.5 cpd (cycles per degree)1.88 log unitsStandard Deviation 0.2
Acri LISA IOLContrast SensitivityMesopic Conditions w/glare, 18 cpd0.30 log unitsStandard Deviation 0
Acri LISA IOLContrast SensitivityContrast Sensitivity 1.5 cpd (cycles per degree)1.78 log unitsStandard Deviation 0.27
Acri LISA IOLContrast SensitivityContrast Sensitivity 3 cpd2.01 log unitsStandard Deviation 0.15
Acri LISA IOLContrast SensitivityContrast Sensitivity 6 cpd1.99 log unitsStandard Deviation 0.16
Acri LISA IOLContrast SensitivityContrast Sensitivity 12 cpd1.53 log unitsStandard Deviation 0.22
Acri LISA IOLContrast SensitivityContrast Sensitivity 18 cpd1.07 log unitsStandard Deviation 0.3
Acri LISA IOLContrast SensitivityMesopic Conditions, 1.5 cpd1.83 log unitsStandard Deviation 0.15
Acri LISA IOLContrast SensitivityMesopic Conditions, 3 cpd1.83 log unitsStandard Deviation 0.16
Acri LISA IOLContrast SensitivityMesopic Conditions, 6 cpd1.62 log unitsStandard Deviation 0.25
Acri LISA IOLContrast SensitivityMesopic Conditions, 12 cpd1.16 log unitsStandard Deviation 0.36
Acri LISA IOLContrast SensitivityMesopic Conditions, 18 cpd0.52 log unitsStandard Deviation 0.22
Acri LISA IOLContrast SensitivityMesopic Conditions w/glare, 6 cpd1.26 log unitsStandard Deviation 0.24
Acri LISA IOLContrast SensitivityMesopic Conditions w/glare, 1.5 cpd1.55 log unitsStandard Deviation 0.31
Acri LISA IOLContrast SensitivityMesopic Conditions w/glare, 3 cpd1.52 log unitsStandard Deviation 0.24
Acri LISA IOLContrast SensitivityMesopic Conditions w/glare, 12 cpd0.73 log unitsStandard Deviation 0.19
Secondary

Defocus Curve

Defocus cureve. A defocus curve is created by multiple measurements of one's visual acuity at different spherical powers. Visual Acuity (VA) is measured in logMAR. LogMAR is the logarithm of the minimum angle of resolution. A lower logMAR value indicates better visual acuity.

Time frame: 6 months post-operative

ArmMeasureGroupValue (MEAN)Dispersion
ReSTOR Aspheric +4Defocus CurveNegative Defocus Curve, -4.0 Diopter0.24 logMARStandard Deviation 0.14
ReSTOR Aspheric +4Defocus CurveNegative Defocus Curve, -3.0 Diopter0.0 logMARStandard Deviation 0.08
ReSTOR Aspheric +4Defocus CurveNegative Defocus Curve, -0.5 Diopter0.06 logMARStandard Deviation 0.11
ReSTOR Aspheric +4Defocus CurveNegative Defocus Curve, -4.5 Diopter0.38 logMARStandard Deviation 0.1
ReSTOR Aspheric +4Defocus CurveNegative Defocus Curve, 0.0 Diopter-0.08 logMARStandard Deviation 0.07
ReSTOR Aspheric +4Defocus CurveNegative Defocus Curve, -2.5 Diopter0.09 logMARStandard Deviation 0.12
ReSTOR Aspheric +4Defocus CurvePositive Defocus Curve, 2.0 Diopter0.61 logMARStandard Deviation 0.11
ReSTOR Aspheric +4Defocus CurveNegative Defocus Curve, -1.0 Diopter0.21 logMARStandard Deviation 0.14
ReSTOR Aspheric +4Defocus CurvePositive Defocus Curve, 1.5 Diopter0.45 logMARStandard Deviation 0.13
ReSTOR Aspheric +4Defocus CurveNegative Defocus Curve, -2.0 Diopter0.29 logMARStandard Deviation 0.13
ReSTOR Aspheric +4Defocus CurvePositive Defocus Curve, 1.0 Diopter0.26 logMARStandard Deviation 0.13
ReSTOR Aspheric +4Defocus CurveNegative Defocus Curve, -3.5 Diopter0.08 logMARStandard Deviation 0.08
ReSTOR Aspheric +4Defocus CurvePositive Defocus Curve, 0.5 Diopter0.03 logMARStandard Deviation 0.11
ReSTOR Aspheric +4Defocus CurveNegative Defocus Curve, -1.5 Diopter0.31 logMARStandard Deviation 0.15
ReSTOR Aspheric +4Defocus CurvePositive Defocus Curve, 0.0 Diopter-0.08 logMARStandard Deviation 0.08
ReSTOR Aspheric +4Defocus CurveNegative Defocus Curve, -5.0 Diopter0.55 logMARStandard Deviation 0.13
Acri LISA IOLDefocus CurvePositive Defocus Curve, 0.0 Diopter-0.09 logMARStandard Deviation 0.08
Acri LISA IOLDefocus CurveNegative Defocus Curve, -5.0 Diopter0.58 logMARStandard Deviation 0.12
Acri LISA IOLDefocus CurveNegative Defocus Curve, -4.5 Diopter0.42 logMARStandard Deviation 0.13
Acri LISA IOLDefocus CurveNegative Defocus Curve, -4.0 Diopter0.27 logMARStandard Deviation 0.12
Acri LISA IOLDefocus CurveNegative Defocus Curve, -3.5 Diopter0.08 logMARStandard Deviation 0.11
Acri LISA IOLDefocus CurveNegative Defocus Curve, -3.0 Diopter0.02 logMARStandard Deviation 0.09
Acri LISA IOLDefocus CurveNegative Defocus Curve, -2.5 Diopter0.08 logMARStandard Deviation 0.11
Acri LISA IOLDefocus CurveNegative Defocus Curve, -2.0 Diopter0.27 logMARStandard Deviation 0.16
Acri LISA IOLDefocus CurveNegative Defocus Curve, -1.5 Diopter0.32 logMARStandard Deviation 0.14
Acri LISA IOLDefocus CurveNegative Defocus Curve, -1.0 Diopter0.17 logMARStandard Deviation 0.12
Acri LISA IOLDefocus CurveNegative Defocus Curve, -0.5 Diopter0.02 logMARStandard Deviation 0.1
Acri LISA IOLDefocus CurveNegative Defocus Curve, 0.0 Diopter-0.10 logMARStandard Deviation 0.08
Acri LISA IOLDefocus CurvePositive Defocus Curve, 2.0 Diopter0.57 logMARStandard Deviation 0.13
Acri LISA IOLDefocus CurvePositive Defocus Curve, 1.5 Diopter0.44 logMARStandard Deviation 0.12
Acri LISA IOLDefocus CurvePositive Defocus Curve, 1.0 Diopter0.27 logMARStandard Deviation 0.12
Acri LISA IOLDefocus CurvePositive Defocus Curve, 0.5 Diopter0.02 logMARStandard Deviation 0.13

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026