Skip to content

Effect of Forced-air Warming and Circulating-water Mattress in Preventing Heat Loss During Vascular Surgery

Effect of Forced-air Warming and Circulating-water Mattress in Preventing Heat Loss During Vascular Surgery

Status
Completed
Phases
Phase 2
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT00712023
Enrollment
44
Registered
2008-07-09
Start date
2007-07-31
Completion date
2008-09-30
Last updated
2009-09-29

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Circulating-water Mattress, Forced-air Warming Mattress, Hypothermia, Vascular Surgery

Keywords

Hypothermia, Vascular surgery, Forced-air warming mattress, Circulating-water mattress

Brief summary

The purpose of this study is to determine whether a custom-made forced-air warming mattress can prevent heat loss in patients undergoing vascular surgery better than a circulating-water mattress

Detailed description

A reusable, custom-made forced-air warming mattress was made of a light to medium weight water resistant canvas, sewn like mattress with 2 arms placed underneath the patient. An open hole at proximal part of one arm was designed to attach with a hose of warm air delivery device. Small holes (2-3 mm2), 5 inches apart were punched on the upper surface of this mattress around the patient except for the area underneath the patient that the holes were 9 inches apart. The weight of the patient will obstruct the air flow and prevent direct blowing of warm air onto the underside of patients. There is a special appendage connected to the upper part of mattress which can connect warm air to cover the patient's chest. There is a special appendage connected to the upper part of mattress which can convect warm air to cover the patient's chest. The mattress is 97 inches x 97 inches, with 2 arms of 25 inches x 16 inches and a special appendage of 45 inches x 12 inches for covering the chest with warm air delivery. This size is proper for patient of 170 cm. height. In order to reuse it, the mattress can be washed, dried and sterilized by gas or autoclaved for more than 50 times. A sterile sheet well enhance the sterile environment of the operating field.

Interventions

DEVICEwarming device (a reusable, custom-made forced- air warming mattress)

2=forced-air warming mattress 1=circulating-water mattress

Sponsors

Mahidol University
Lead SponsorOTHER

Study design

Allocation
RANDOMIZED
Intervention model
PARALLEL
Primary purpose
PREVENTION
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
20 Years to 85 Years
Healthy volunteers
Yes

Inclusion criteria

Patients undergoing vascular surgery

Exclusion criteria

Preoperative fever

Design outcomes

Primary

MeasureTime frame
skin and nasopharyngeal temperature180 min

Secondary

MeasureTime frame
burn wound3 days

Countries

Thailand

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026