Skip to content

Monitoring of Fluid Status in Heart Failure Patients by Intrathoracic Impedance Measurement (HomeCARE II)

Monitoring of Fluid Status in Heart Failure Patients by Intrathoracic Impedance Measurement

Status
Completed
Phases
Phase 4
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT00711360
Acronym
HomeCARE II
Enrollment
303
Registered
2008-07-08
Start date
2008-07-31
Completion date
2012-09-30
Last updated
2012-09-26

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Arrhythmias, Cardiac, Heart Failure

Keywords

heart failure, implantable cardioverter-defibrillator, intrathoracic impedance, cardiac resynchronization therapy, home monitoring

Brief summary

The new BIOTRONIK implantable cardioverter defibrillator (ICD) family Lumax 540 is capable of measuring the intrathoracic impedance on a daily basis and transmission of impedance trend data via the Home Monitoring technology. In future, this will allow for automatic early detection of imminent decompensation at a presymptomatic stage and immediate initialization of clinical meaningful therapeutic interventions preventing heart failure related hospitalizations. The aim of this investigation is to record long-term impedance trends in heart failure patients with and without heart failure related events (hospitalizations due to acute decompensation) in order to develop algorithms for device-based early detection and warning of HF deterioration accompanied by pulmonary congestion.

Detailed description

The new BIOTRONIK implantable cardioverter defibrillator (ICD) family Lumax 540 is capable of measuring the intrathoracic impedance on a daily basis and transmission of impedance trend data via the Home Monitoring technology. In future, this will allow for automatic early detection of imminent decompensation at a presymptomatic stage and immediate initialization of clinical meaningful therapeutic interventions preventing heart failure related hospitalizations. The aim of this investigation is to record long-term impedance trends in heart failure patients with and without heart failure related events (hospitalizations due to acute decompensation) in order to develop algorithms for device-based early detection and warning of HF deterioration accompanied by pulmonary congestion. Lumax is the name of a family of implantable ICDs. The primary objective of the therapy is the prevention of sudden cardiac death. The aim is to automatically detect and terminate cardiac arrest caused by ventricular tachyarrhythmia. All major therapeutical approaches from the field of cardiology and electrophysiology are contained within the Lumax family. Furthermore, the device is capable of treating bradycardia arrhythmias and congestive heart failure. Congestive heart failure is treated with cardiac resynchronization therapy with multisite ventricular pacing known as cardiac resynchronization therapy (CRT). The integrated Home Monitoring component can provide information about occurring rhythm disturbances and delivered therapies close to real time as well as by intracardiac electrogram (IEGM) Online HD®. Furthermore, statistical data about the patient's condition as well as information about the integrity status of the implant itself are sent. The implantation of an ICD is a symptomatic therapy with the following objectives: * Termination of spontaneous ventricular fibrillation (VF) through shock delivery * Termination of spontaneous ventricular tachycardia (VT) by means of antitachycardia pacing (ATP); in case of ineffective ATP or hemodynamically not tolerated VT with shock delivery * Cardiac resynchronization by multisite ventricular pacing (triple-chamber implant) * Compensation of bradycardia through ventricular (single-chamber implant) or atrioventricular sequential pacing (dual- and triple-chamber implant)

Interventions

DEVICEIntrathoracic impedance measurement

Intrathoracic impedance measurement by cardiac resynchronization therapy (CRT) devices and implantable cardioverter defibrillators (ICDs) (Lumax 540)

Sponsors

Biotronik SE & Co. KG
Lead SponsorINDUSTRY

Study design

Allocation
NA
Intervention model
SINGLE_GROUP
Primary purpose
SUPPORTIVE_CARE
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* Patient eligible for 1-, 2- or 3-chamber ICD implantation according to current guidelines or patient already implanted with a Lumax 540 device or successor * NYHA-class II to IV * LVEF lower or equal to 35% * Patient accepts Home Monitoring concept and has sufficient GSM/GPRS net coverage * Increased risk for HF-related hospitalization according to pre-defined criteria * Patient information * Informed consent

Exclusion criteria

* Age \< 18 years * Contraindication for ICD implantation * Post HTX or actively listed for HTX * Cardiac surgery within the previous 3 months or planned at time of inclusion * Acute coronary syndrome within the previous 3 months * Chronic renal dialysis * Pregnant or breast-feeding women * Limited contractual capability * Participation in another study * Anticipated non-compliance with the follow-up scheme * Life expectancy not longer than 1.5 years due to a non-cardiac disease

Design outcomes

Primary

MeasureTime frame
Long-term impedance trends in patients with clinically relevant heart failure events, to support the development of impedance based detection algorithms. A posterior assessment of sensitivity and false alarm rate of the detection algorithms.Study will last until 35 heart failure events are collected

Secondary

MeasureTime frame
Further improvement of the Heart Failure Monitor based on collected dataThe same as for primary outcome measure

Countries

Germany, Spain, Switzerland

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Mar 4, 2026