Continuous Glucose Monitoring in Critically Ill

Continuous Glucose Monitoring Device Compared With Point-of-Care Glucose Testing in the ICU

Status
Terminated
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT00707434
Enrollment
6
Registered
2008-06-30
Start date
2008-06-30
Completion date
2016-09-30
Last updated
2020-03-23

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Diabetes

Keywords

Continuous Glucose Monitor, Medtronic Guardian, Guardian® blood-sugar monitoring device, Glucose Monitoring, Critically Ill, ICU, Intensive Care Unit, Glycemic Excursions, Glucose Control, Glucose Testing, Hyperglycemia, Hypoglycemia, Insulin Infusion

Brief summary

The goal of this clinical research study is to learn if The Guardian® blood-sugar monitoring device can be used reliably in patients with high blood sugar who are receiving care in the ICU. Researchers will compare blood-sugar measurements from the study device with blood-sugar measurements from the standard fingerstick method of blood-sugar testing. This is being done to see if the new device can accurately measure blood sugar.

Detailed description

The Study Device: The Guardian® blood-sugar monitoring device is designed to automatically record blood sugar levels many times per hour, without requiring multiple fingersticks. It uses a blood sugar sensor (an electronic measuring device) that is about the size of a beeper. The sensor is attached to a small catheter that has a small needle in it. Once the catheter is inserted in the skin, the needle is removed right away. Use of Study Device: If you agree to take part in this study, while you are in the ICU, the catheter and needle part of the study device will be inserted under the skin of your abdomen or thigh. The device will automatically measure your blood sugar every 10 seconds so the data can be reviewed by the research staff. The needle will be removed right away. The catheter must be changed every 3 days (+/- 3 days) by the research staff. You will have the study device in place for 15 days (or until you leave the ICU, whichever comes first). Standard Monitoring of Blood Sugar Levels: While you are on study, your blood sugar will also be monitored according to the standard of care. This will be in the form of having your blood sugar checked by using a small needle to prick the tip of your finger every hour or more, as necessary. The blood sugar measurements from the study device will not be used in any way to affect any decisions about your blood sugar monitoring or care. Length of Study Participation: After the study device is removed from your body for the last time (after 15 days or when you leave the ICU), you will be considered off study. If intolerable side effects occur, or an infection occurs that seems to have been caused by the study device, you will be taken off study early. This is an investigational study. The study device is commercially available and FDA approved for monitoring blood sugar levels for outpatient (outside of the hospital) use. Using the device in patients who are in the hospital is considered experimental. At this time, it is only being used in this way in research. Up to 60 patients will take part in this multicenter study. Up to 25 will be enrolled at M. D. Anderson.

Interventions

DEVICEGuardian® blood-sugar monitoring device

The device has a small catheter that will be inserted subcutaneous tissue of the subject's abdomen or thigh set to continuously monitor glucose throughout the ICU stay for up to 15 days.

Sponsors

Medtronic
CollaboratorINDUSTRY
M.D. Anderson Cancer Center
Lead SponsorOTHER

Study design

Allocation
NA
Intervention model
SINGLE_GROUP
Primary purpose
SUPPORTIVE_CARE
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

1. Patients in any of our University of Texas collaborative intensive care units. 2. Critically ill patients on an insulin infusion protocol

Exclusion criteria

1. Patients or their legal representatives who do not consent 2. Patients with large areas of skin affected so as not to allow implantation of device. 3. Patients \< 18 years of age

Design outcomes

Primary

MeasureTime frameDescription
Mean Relative Difference in Patient Glucose Monitoring: Continuous Glucose Monitoring (CGM) Device as Compared With Point of Care (POC) Glucose TestingContinuously monitor patient's glucose throughout their ICU stay for up to 15 days.Mean relative difference will be calculated on a patient level assuming that at least 6 paired measurements will be collected from each patient. Outcome represents reliability of CGM device as compared with POC glucose testing where glucose values measured by POC will only be compared with the values read by the continuous glucose monitor sensor at the corresponding time points. The primary outcome for each patient is the mean relative difference defined as average of relative difference at each time point, where relative difference at each time point is calculated by taking difference in glucose values between CGM and POC and then divided by POC glucose value.

Countries

United States

Participant flow

Recruitment details

Recruitment period: June 12, 2008 to May 19, 2011. All recruitment was done at The University of Texas (UT) and UT MD Anderson Cancer Center.

Participants by arm

ArmCount
Continuous Glucose Monitoring in ICU
Continuous glucose monitoring in critically ill patients throughout an intensive care unit (ICU) stay up to 15 days.
6
Total6

Withdrawals & dropouts

PeriodReasonFG000
Overall StudyAdverse Event1

Baseline characteristics

CharacteristicContinuous Glucose Monitoring in ICU
Age, Continuous54 years
Ethnicity (NIH/OMB)
Hispanic or Latino
0 Participants
Ethnicity (NIH/OMB)
Not Hispanic or Latino
6 Participants
Ethnicity (NIH/OMB)
Unknown or Not Reported
0 Participants
Race (NIH/OMB)
American Indian or Alaska Native
0 Participants
Race (NIH/OMB)
Asian
0 Participants
Race (NIH/OMB)
Black or African American
0 Participants
Race (NIH/OMB)
More than one race
0 Participants
Race (NIH/OMB)
Native Hawaiian or Other Pacific Islander
0 Participants
Race (NIH/OMB)
Unknown or Not Reported
0 Participants
Race (NIH/OMB)
White
6 Participants
Region of Enrollment
United States
6 participants
Sex: Female, Male
Female
2 Participants
Sex: Female, Male
Male
4 Participants

Adverse events

Event typeEG000
affected / at risk
deaths
Total, all-cause mortality
0 / 6
other
Total, other adverse events
1 / 6
serious
Total, serious adverse events
0 / 6

Outcome results

Primary

Mean Relative Difference in Patient Glucose Monitoring: Continuous Glucose Monitoring (CGM) Device as Compared With Point of Care (POC) Glucose Testing

Mean relative difference will be calculated on a patient level assuming that at least 6 paired measurements will be collected from each patient. Outcome represents reliability of CGM device as compared with POC glucose testing where glucose values measured by POC will only be compared with the values read by the continuous glucose monitor sensor at the corresponding time points. The primary outcome for each patient is the mean relative difference defined as average of relative difference at each time point, where relative difference at each time point is calculated by taking difference in glucose values between CGM and POC and then divided by POC glucose value.

Time frame: Continuously monitor patient's glucose throughout their ICU stay for up to 15 days.

Population: Study was terminated due to insufficient funding and data were not collected.

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026