Comparison of Breathing Events Detected by the SleepStyle 200 Auto Continuous Positive Airway Pressure (CPAP) Device to Attended Polysomnography

Investigation of Methods to Detect Respiratory Irregularities in Obstructive Sleep Apnea (OSA)

Status
Completed
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT00697424
Enrollment
20
Registered
2008-06-13
Start date
2008-05-31
Completion date
2008-11-30
Last updated
2008-12-09

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Sleep Apnea, Obstructive

Brief summary

Obstructive Sleep Apnoea (OSA) is a common sleep-breathing disorder affecting around 2-4% of the population and is characterised by loud snoring, periodic collapse of the upper airway particular to sleep, sleep fragmentation, and sometimes daytime sleepiness. Health consequences include impaired cognitive functioning, quality of life, mood, and increased cardiovascular disease risk. Epidemiological studies have demonstrated that increased morbidity and mortality in a dose response manner with increasing severity of sleep disordered breathing. The standard treatment for OSA is nasal Continuous Positive Airway Pressure (CPAP), which consists of pressurized air applied to the nose via a mask. Generally a single, optimal pressure is prescribed for a patient based on a full night or partial night study during which the pressure is adjusted by a technician until all sleep disordered breathing (SDB) events are abolished. Despite therapy efficacy, compliance to CPAP therapy is sub-optimal. Due to low compliance it has become common for healthcare providers to follow up subject therapy efficacy through reporting software inherent in many current CPAP devices. Healthcare providers can use this reported data to make appropriate treatment decisions. For this reason the data needs to be accurate. The SleepStyle™ 200 Auto Series CPAP humidifier is an auto adjusting CPAP which stores comprehensive compliance data. The aim of this study is to compare the reliability of the SleepStyle™ 200 Auto Series CPAP data to laboratory-based PSG in detecting sleep disordered breathing. Hypothesis: The SleepStyle™ 200 Auto Series reporting features accurately detects indices of sleep disordered breathing.

Interventions

The device will record on internal software perceived sleep disordered breathing events. Events will also be scored manually on the polysomnography (PSG. Results will then be compared.

Sponsors

Fisher and Paykel Healthcare
Lead SponsorINDUSTRY

Study design

Allocation
NA
Intervention model
SINGLE_GROUP
Primary purpose
TREATMENT
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* Apnea Hypopnea Index (AHI) \>15 from diagnostic night * ≥18 years of age

Exclusion criteria

* Contraindicated for CPAP use

Design outcomes

Primary

MeasureTime frame
Apnea Hypopnea IndexAt the end of the sleep study.

Secondary

MeasureTime frame
Respiratory Disturbance Index (RDI)At the end of the sleep study (PSG)

Countries

New Zealand

Outcome results