Titration Pressures in Sleep Apnea Patients Using ThermoSmart® Versus Conventional Humidification

Titrations Pressures in Sleep Apnea Patients Using ThermoSmart® Versus Conventional Humidification

Status
Completed
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT00681083
Enrollment
26
Registered
2008-05-21
Start date
2008-04-30
Completion date
2008-07-31
Last updated
2019-06-12

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Sleep Apnea, Obstructive

Keywords

Obstructive Sleep Apnea, Humidification, Continuous Positive Airway Pressure

Brief summary

Patients who have Obstructive Sleep Apnea (OSA) may have different Continuous Positive Airway Pressure (CPAP)when titrated with different levels of humidification. It is hypothesised that patients with ThermoSmart® technology (heated breathing tube technology) will have lower titrated pressures than those who are titrated using conventional humidification (non heated breathing tube).

Detailed description

Debate is present concerning the optimal level of humidification for obstructive sleep apnea (OSA) patients who need continuous positive airway pressure (CPAP) therapy. Recent evidence has shown that using a heated breathing tube to increase the amount of humidification that can be delivered has decreased patient side effects, increased subjective sleep quality and decreased subjective symptom scores. Anecdotal evidence exists, in the form of clinical observation, when ThermoSmart® technology is utilized during CPAP titration, patients laboratory titrated pressure may in fact prove to be lower. The possibility exists, on a titration night, patients potentially may experience an adverse response to the positive airway pressure which manifests as increased airway resistance and inflammation necessitating higher CPAP pressures to overcome upper airway resistance and flow limitation. Therefore, we hypothesize the delivery of higher levels of humidity might reduce the nasal airway resistance during the titration night, reducing the overall positive airway pressure requirements. The goal is to investigate this phenomenon to find if a reduction in pressure is necessary and if so to what degree. Patients who are titrated on Continuous Positive Airway Pressure devices with ThermoSmart® technology will have lower titrated pressures than those who are titrated using conventional humidification.

Interventions

DEVICEHeated breathing tube (CPAP with ThermoSmart)

CPAP with ThermoSmart - heated passover humidifier, with heated breathing tube

DEVICENon heated breathing tube (CPAP with conventional humidification)

CPAP with conventional humidification - heated passover humidifier, no heated breathing tube

Sponsors

Sleep Disorder Centers Institute for Clinical Research
CollaboratorUNKNOWN
Fisher and Paykel Healthcare
Lead SponsorINDUSTRY

Study design

Allocation
RANDOMIZED
Intervention model
CROSSOVER
Primary purpose
TREATMENT
Masking
SINGLE (Investigator)

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* Male and Female patients over the age of 18 * Apnea Hypopnea Index (AHI) ≥15 * Patients must have at least 5 hours sleep time on each titration night * Stable medications for 2 weeks prior to entry to the study and for study inclusion duration including sleep aids

Exclusion criteria

* Receiving or requiring bi-level ventilation * Use of a full face interface or chin strap * Previous UPPP surgery or palatal reconstruction * Recent angina symptoms within 2 weeks of entry * CHF with EF \< 40% * Obesity Hypoventilation Syndrome * Cheyne Stokes respiration * \> 50% Central apneas recorded on diagnostic polysomnogram * Supplemental oxygen use * Use of narcotic pain medication * Hypoxemia as determined by room air pulse oxymetry of less than 89% on room air at rest awake * Inability to tolerate positive pressure therapy * Split Night Evaluations

Design outcomes

Primary

MeasureTime frameDescription
Titration Pressures After Treatment NightsEnd of titration nightEach night, the participant underwent a CPAP titration to determine their therapeutic pressure. During a titration, a sleep technician manually adjusts the participants pressure to determine which pressure is best for that individual in reducing their Apnea Hypopnea Index (AHI) which is the measure of Obstructive Sleep Apnea (OSA) severity. Titration pressures for each group were compared to see if there was any impact of having a heated breathing tube versus a non heated breathing tube on titration pressure.

Secondary

MeasureTime frameDescription
Relationship Between the Intervention (Heated Breathing Tube vs Non Heated Breathing Tube) and Total Sleep TimeEnd of titration nightA correlation table was computed to explore the relationship between the intervention (heated breathing tube vs no heated breathing tube) and total sleep time. This relationship was calculated for each arm and reported by a Correlation Coefficient (r score). The r score represents the strength and direction of a relationship between two variables. The value of r is always between -1 and +1. Therefore, an r score of -1 indicates a perfect negative relationship between the intervention and total sleep time. An r score of -.50 indicates a moderate negative relationship between the intervention and total sleep time. An r score of 0 indicates no relationship between the intervention and total sleep time. An r score of +.50 indicates a moderate positive relationship between the intervention and total sleep time. An r score of +1 indicates a perfect positive relationship between the intervention and total sleep time.

Countries

United States

Participant flow

Participants by arm

ArmCount
All Study Participants
All Study participants. Note: participants took part in both arms as it was a cross over trial
20
Total20

Baseline characteristics

CharacteristicAll Study Participants
Age, Continuous48.35 years
Race (NIH/OMB)
American Indian or Alaska Native
0 Participants
Race (NIH/OMB)
Asian
0 Participants
Race (NIH/OMB)
Black or African American
2 Participants
Race (NIH/OMB)
More than one race
0 Participants
Race (NIH/OMB)
Native Hawaiian or Other Pacific Islander
0 Participants
Race (NIH/OMB)
Unknown or Not Reported
2 Participants
Race (NIH/OMB)
White
16 Participants
Sex: Female, Male
Female
10 Participants
Sex: Female, Male
Male
10 Participants

Adverse events

Event typeEG000
affected / at risk
EG001
affected / at risk
deaths
Total, all-cause mortality
0 / 200 / 20
other
Total, other adverse events
0 / 200 / 20
serious
Total, serious adverse events
0 / 200 / 20

Outcome results

Primary

Titration Pressures After Treatment Nights

Each night, the participant underwent a CPAP titration to determine their therapeutic pressure. During a titration, a sleep technician manually adjusts the participants pressure to determine which pressure is best for that individual in reducing their Apnea Hypopnea Index (AHI) which is the measure of Obstructive Sleep Apnea (OSA) severity. Titration pressures for each group were compared to see if there was any impact of having a heated breathing tube versus a non heated breathing tube on titration pressure.

Time frame: End of titration night

ArmMeasureValue (MEAN)Dispersion
Heated Breathing TubeTitration Pressures After Treatment Nights9.8 cmH20Standard Deviation 1.89
Non Heated Breathing TubeTitration Pressures After Treatment Nights10.9 cmH20Standard Deviation 1.98
Secondary

Relationship Between the Intervention (Heated Breathing Tube vs Non Heated Breathing Tube) and Total Sleep Time

A correlation table was computed to explore the relationship between the intervention (heated breathing tube vs no heated breathing tube) and total sleep time. This relationship was calculated for each arm and reported by a Correlation Coefficient (r score). The r score represents the strength and direction of a relationship between two variables. The value of r is always between -1 and +1. Therefore, an r score of -1 indicates a perfect negative relationship between the intervention and total sleep time. An r score of -.50 indicates a moderate negative relationship between the intervention and total sleep time. An r score of 0 indicates no relationship between the intervention and total sleep time. An r score of +.50 indicates a moderate positive relationship between the intervention and total sleep time. An r score of +1 indicates a perfect positive relationship between the intervention and total sleep time.

Time frame: End of titration night

ArmMeasureValue (NUMBER)
Heated Breathing TubeRelationship Between the Intervention (Heated Breathing Tube vs Non Heated Breathing Tube) and Total Sleep Time.535 r score
Non Heated Breathing TubeRelationship Between the Intervention (Heated Breathing Tube vs Non Heated Breathing Tube) and Total Sleep Time.058 r score

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026