Skip to content

INSIGHT (R)XT. Indications for Diagnosis, Arrhythmia and Monitoring of Reveal XT

Indications for Diagnosis, Arrhythmia and Monitoring of Reveal XT.

Status
Completed
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT00680550
Enrollment
1003
Registered
2008-05-20
Start date
2008-04-30
Completion date
2013-04-30
Last updated
2013-10-16

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Atrial Fibrillation, Cardiac Arrhythmias

Keywords

Atrial Fibrillation, Risk of cardiac Arrhythmias, Loop recorder

Brief summary

To describe the clinical indications for Reveal XT in diagnosis and continuous monitoring of arrhythmia and to explore the clinical applications and outcome of arrhythmia monitoring on patient care.

Detailed description

Improving the diagnosis and management of cardiac rhythm disturbances remains a major challenge for physicians. Limitations of current cardiac arrhythmia monitoring using ECG, holters or event recorders are that these methods are non-continuous and/or automatic arrhythmia detection is often impossible. The Medtronic Reveal XT Insertable Cardiac Monitor is a programmable device which continuously monitors the patient's subcutaneous ECG and provides information regarding arrhythmia episodes, long term trending of AF burden, patient's activity and heart rate variability. The Reveal XT records cardiac information in response to patient activation and automatically detected arrhythmias thereby offering advantages over conventional tools for long-term arrhythmia monitoring with regard to compliance and recording time. The clinical applications for Reveal XT are varied. Diagnostic, arrhythmia monitoring and arrhythmia management functions can be discriminated. This study is a prospective, observational, multicenter international post-market study. The results of this study will describe the different patient groups for which the Reveal XT is being used for the diagnosis and monitoring of various cardiac arrhythmias. This study will also collect data regarding the clinical consequences of using the Reveal XT and the influence of Reveal XT data on clinical care pathways. The physician as well as the patient's satisfaction with the device will be evaluated. The study will be conducted in 60-100 centers primarily in Europe. It is expected that 800-1000 patients will be enrolled.

Interventions

None listed

Sponsors

Medtronic BRC
Lead SponsorINDUSTRY

Study design

Time perspective
PROSPECTIVE

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* Patient implanted or scheduled for an implant with a Reveal XT Insertable Cardiac Monitor System for arrhythmia diagnosis or monitoring * Patient must be willing to sign a Patient Data Release Form (or Informed Consent where applicable)

Exclusion criteria

* Enrollment outside a 30-day window from the planned/performed Reveal XT implant procedure (from 15 days pre-implant until 15 days post implant) * Patient is implanted with a pacemaker, ICD, CRT-device or an implantable hemodynamic monitoring system * Unwillingness or inability to cooperate or give written informed consent or, if the patient is a minor and the legal guardian refuses to give consent

Design outcomes

Primary

MeasureTime frameDescription
descriptive: clinical indications for Reveal XT2008-2012To describe the patient population implanted with a Reveal XT for arrhythmia diagnosis and monitoring

Countries

Austria, Belarus, Czechia, Finland, Germany, Italy, Netherlands, Portugal, Russia, Slovakia, Slovenia, Spain, Sweden, Switzerland, United Arab Emirates, United Kingdom

Outcome results

None listed