Respiratory Failure
Conditions
Keywords
mechanical ventilation, automated weaning, children
Brief summary
The purpose of this study is to determine whether a computer-driven system (Smartcare/PS) decreases weaning duration from mechanical ventilation when compared to usual care in children.
Detailed description
Baseline data: All subjects included into this RCT will undergo routine examination upon admission to the hospital. These examinations include physical, medical/medication history (on the last year for medical history and the last 3 months for medication history (if available), vital signs, radiologic data and laboratory tests. Intervention: A pre-inclusion test (pressure support test) with a level of pressure support of ± 5 cmH2O of the P plateau, but no greater than 30 cmH2O (pressure-support level plus positive end-expiratory pressure), is performed to evaluate the patient's tolerance of this ventilation mode; the test is repeated daily until positive. The test could be stopped before 30 minutes if the patient showed evidence of respiratory distress (respiratory rate \> 40 breaths per minute and FiO2 \> 60% in order to obtain pulse oxymetry ≥ 95%). The test is considered positive when, after 30 minutes, the patient remained clinically stable with a respiratory rate lower than 40 breaths per minute and an expiratory tidal volume higher than 6 ml per kilogram of body weight within the authorized pressure-support range, with pulse oxymetry no lower than 95 percent when the fraction of inspired oxygen was no greater than 60 percent. When the pressure-support test is positive, the patient is randomized either to Arm 1 where the intervention is weaning with the support of Smartcare/PS or to Arm 2 where the intervention is weaning based on usual care. Both group are ventilated with the same ventilator: Evita XL.
Interventions
computer-driven protocol that adjusts pressure support level in pressure support mode to patient respiratory status
Sponsors
Study design
Eligibility
Inclusion criteria
* The attending physician thinks that the patient will be able to breathe spontaneously or the patients is already breathing spontaneously. * No vasopressor or inotropic medication, unless the patient is receiving some digitalin or small doses of dopamine (\< 5 µg/kg/min) * Slight or no endotracheal tube gas-leakage (\[Vti - Vte\]/Vti ≤ 20%) * Mechanical ventilation with a plateau pressure ≤ 25 cmH2O over PEEP * PEEP ≤ 8 cmH2O * FiO2 ≤ 60% in order to obtain pulse oxymetry ≥ 95% * PaCO2 \< 70 mmHg on the last blood gases * Extubation not expected the day of inclusion
Exclusion criteria
* N/A
Design outcomes
Primary
| Measure | Time frame |
|---|---|
| Length of weaning from mechanical ventilation that corresponds to the time from Time 0 to the first extubation. | first extubation or 28 days |
Secondary
| Measure | Time frame |
|---|---|
| Total mechanical ventilation duration | first extubation or 28 days |
| Proportion of time in the acceptable breathing zone | first extubation or 28 days |
| Weaning failure | 48 hours after first extubation |
| Number of interventions on the ventilator by a physician or physiotherapist | First extubation or 28 days |
Countries
Canada