Skip to content

Transapical Implantation of Ventor Embracer™ Valve in Patients With Severe Aortic Valve Disease

Catheter-Based Transapical Implantation of the Ventor Embracer™ Heart Valve Prosthesis in Patients With Severe Aortic Valve Disease

Status
UNKNOWN
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT00677638
Enrollment
30
Registered
2008-05-14
Start date
2008-06-30
Completion date
2014-12-31
Last updated
2009-12-03

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Aortic Valve Disease

Brief summary

A prospective single arm study evaluating feasibility and safety of a catheter-based transapical implantation of the Ventor Embracer™ aortic valve bioprosthesis in patients with severe aortic valve disease, specifically aortic stenosis, who are at elevated risk for standard surgical valve replacement.

Interventions

DEVICEVentor Embracer

Implantation of Ventor Embracer

Sponsors

Ventor Technologies
Lead SponsorINDUSTRY

Study design

Allocation
NA
Intervention model
SINGLE_GROUP
Primary purpose
TREATMENT
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
75 Years to No maximum
Healthy volunteers
No

Inclusion criteria

1. Patient understands the implications of participating in the study and provides informed consent 2. Patient is willing to comply with specified follow-up evaluation and can be contacted by telephone 3. Age \>75 years 4. Severe, aortic stenosis (echocardiographically derived mean gradient \> 40 mm Hg, and/or jet velocity \> 4m/s, or an initial aortic valve area of \< 0.8 cm2) 5. Symptoms related to the aortic valve disease, as demonstrated by NYHA Functional Class II or greater 6. EuroSCORE scale of \>9 points indicating a predicted risk for mortality of \>11% according to the logistic EuroSCORE 7. Echocardiographically determined anteroposterior aortic annulus diameter of \>19 and \<23 mm 8. Echocardiographically determined sinotubular junction diameter of ≥23 mm

Exclusion criteria

1. Congenital unicuspid or bicuspid aortic valve 2. Fused commissures 3. Severe eccentricity of calcification 4. Echocardiographic evidence of intracardiac mass, thrombus, or vegetation. 5. Severe left ventricular dysfunction (LVEF \< 25%) 6. More than mild right ventricular dysfunction 7. Hypertrophic obstructive cardiomyopathy 8. Moribund patients, or patients with a noncardiac disease limiting by itself life expectancy to less than 12 months 9. Known hypersensitivity or contraindication to any study medication 10. Known sensitivity to contrast medium that cannot be adequately controlled with pre-medication 11. Known allergy or sensitivity to Nitinol 12. Sepsis, or acute endocarditis 13. Blood dyscrasia such as acute anemia, leucopenia, or thrombocytopenia; bleeding diathesis, or coagulopathy. 14. Renal insufficiency and/or end stage renal disease requiring chronic dialysis 15. Liver disease as indicated by jaundice, ascites, ALT/AST \> 3 x ULN, elevation of total bilirubin \> 1.5 mg/dl, albumin \< 3.0 g/l, or INR \> 1.5 (if not on anticoagulation). 16. Significant lung disease (e.g. FEV1 \< 1.2L or FEV1 \< 50%). 17. Active peptic ulcer or GI bleeding within 3 months from the planned index procedure 18. Untreated clinically significant coronary artery disease requiring revascularisation 19. Cardiogenic shock, suspected cardiogenic shock, or hemodynamic instability requiring inotropic support or mechanical heart assistance 20. Peripheral vascular disease, including abdominal and thoracic aortic disease, which could pose a problem for eventual transarterial mechanical support (e.g. Intraaortic Balloon Pump) 21. Need for emergency surgery, cardiac or noncardiac 22. History of myocardial infarction in the last 6 weeks. 23. History of TIA or stroke in the last 6 months. 24. Any therapeutic invasive cardiac procedure, except aortic balloon valvuloplasty, performed within 30 days from the planned index procedure, or 6 months, in case of implantation of drug-eluting stents. 25. Uncontrolled atrial fibrillation 26. Pre-existing aortic valve replacement 27. Severe (greater than 3+) mitral regurgitation 28. Severe (greater than 3+) aortic regurgitation 29. Patient is currently enrolled in another investigational device or drug trial

Design outcomes

Primary

MeasureTime frame
Stable device placement and adequate function as assessed by angiography and echocardiography immediately post-procedureday one
A composite of any death, myocardial infarction, or disabling stroke at 30 days post-procedure30 days

Secondary

MeasureTime frame
Any of the following adverse events: death, disabling stroke, repeat aortic valve procedure or endocarditis at 6 months6 months
Freedom from death at 1 year1 year
Device success and the absence of periprocedural MACCEs at post-operative day 1day one
Peak & mean pressure gradient, derived calculated measures of prosthetic valve function, aortic regurgitation - assessed by echocardiography immediately after deployment, at POD 1, 30 days, 6 months and 5 years annually5 years
Functional improvement from baseline per New York Heart Association (NYHA) functional classification at 30 days, 6 months and 1 year1 year
Any of the following adverse events: death, myocardial infarction, disabling stroke, repeat aortic valve procedure, cardiogenic shock, or endocarditis at 30 days30 days

Countries

Germany

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Mar 30, 2026