Spontaneous Atrio Ventricular Conduction Preservation

Spontaneous Atrio Ventricular Conduction Preservation

Status
Completed
Phases
Phase 4
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT00655213
Acronym
SAVER
Enrollment
622
Registered
2008-04-09
Start date
2003-11-30
Completion date
2006-12-31
Last updated
2008-04-09

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Bradycardia-Tachycardia Syndrome, Paroxysmal Atrioventricular Block, Sinus Node Dysfunction

Keywords

Pacing, AV conduction disorders, minimized ventricular pacing, AF

Brief summary

In case of sinus node dysfunction, it is often necessary to choose the safer option provided by a DDD pacemaker even though the most appropriate mode of pacing is AAI mode. In addition to saving energy, the latter mode allows spontaneous ventricular activation, the haemodynamic consequences of which are, in most cases, better than those obtained with dual chamber pacing. Recent studies as the MOST study suggest also that ventricular desynchronization imposed by right ventricular apical pacing even when AV synchrony is preserved increases the risk of atrial fibrillation in patients with SND. Similar results were already given by anterior studies (PIPAF) which, taking into account the percentage of ventricular pacing, suggested that AF prevention algorithm in combination with a preserved native conduction are efficient in reducing AF burden. However, current practice is to implant a dual chamber pacemaker to prevent the risk of atrioventricular block (AVB) even if DDDR pacing with a fixed long AV delay was found inefficient in reducing ventricular pacing and was associated with a high risk of arrhythmias. The Symphony 2550 cardiac pacemaker offers pacing modes that automatically switch from AAI(R) mode to DDD(R) or DDI(R) in event of severe atrioventricular conduction disorder, irrespective of whether or not these are accompanied by an atrial arrhythmia, returning spontaneously to AAI(R) mode as soon as the spontaneous AV conduction has resumed. These 2 particular modes are called the AAI SafeR and DDD/AMC (R) mode. The main differences between both modes are that (i) AAI SafeR does not trigger any AV Delay after a sensed or paced atrial event which allows long PR intervals or even limited ventricular pauses with no switch to DDD(R), while (ii) DDD/AMC (R) is able to optimize AV Delay after switching to DDD(R) according to measured spontaneous conduction times and to provide an acceleration in case of vaso-vagal syndrome. This pacing mode has previously been assessed in clinical studies. This study intends to demonstrate that the automatic modes switching significantly reduce the percentage of ventricular pacing in patients implanted with a spontaneous AV conduction and reduce the occurrence of atrial arrhythmias, on a mid-term follow-up period, in comparison to standard DDD pacing with long AVDelay.

Interventions

DEVICESymphony D 2450
DEVICESymphony DR 2550

Sponsors

LivaNova
Lead SponsorINDUSTRY

Study design

Allocation
RANDOMIZED
Intervention model
PARALLEL
Primary purpose
TREATMENT
Masking
DOUBLE (Subject, Investigator)

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* Patient has been primo-implanted with a Symphony™ 2550 or 2450 devices for less than 3 months * Patient with a normal spontaneous AV conduction at rest (PR \< 250 ms) * Patient implanted for Sinus Node Dysfunction, Braycardia-Tachycardia Syndrome, carotid sinus syndrome/ vaso vagal syndrome or paroxistic AV Block * Patient implanted with a bipolar right-atrial lead and ventricular lead available in the local market * Patient has signed a consent form after having received the appropriate information

Exclusion criteria

* Permanent 1st, 2nd or 3rd AV block * Patient having a medical status complying with one of the following cases * patient suffering from sustained ventricular arrhythmias * patient having sustained a myocardial infarction within the last month * patient having undergone cardiac surgery within the last month * patient suffering from severe aortic stenosis * patient suffering from unstable angina pectoris * patient presents with permanent atrial arrhythmias * Patient is not able to understand the study objectives and protocol or refuses to co-operate * Patient is not available for scheduled follow-up * Patient has a life expectancy less than one year * Patient is included into another clinical study * Patient is minor or a pregnant woman

Design outcomes

Primary

MeasureTime frame
mean percentage of ventricular pacing between the randomized branches on a two-months period (M3 visit)2 months
mean percentage of ventricular pacing between the studied groups during the whole study (up to 1 year).12 months

Secondary

MeasureTime frame
percentage of ventricular pacing two month after randomization versus the percentage reported at the end of the first month follow-up in AAIsafeR mode.12 months
AF burden relatively to the branch of the protocol12 months
evolution of conduction disturbances by documentings nature, number and duration of ario-ventricular blocks.12 months

Countries

Belgium, France, Germany, Italy, United Kingdom