Skip to content

Agreement Between Spectral Domain and Time Domain Optical Coherence Tomography (OCT)

Agreement in Foveal Thickness Measurements Between Spectralis® and Stratus® Optical Coherence Tomography

Status
UNKNOWN
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT00651989
Enrollment
40
Registered
2008-04-03
Start date
2008-04-30
Completion date
2008-05-31
Last updated
2008-04-03

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Normal Foveal Thickness

Keywords

optical coherence tomography, spectral domain, time domain

Brief summary

Optical coherence tomography (OCT) is a well-established and safe technique that offers the possibility of visualizing retinal structure and measuring retinal thickness. Time-domain (TD)OCT is considered the gold standard technique for retinal thickness measurements. Spectral-domain (SD) OCT has to face the gold standard technique prior to obtain scientific and clinical consensus. In our study in healthy subjects foveal thickness will be measured with both TD and SD OCT , and the data will be compared to evidence any difference between the two retinal measurements techniques.

Detailed description

The study will be performed at the Ophthalmology Clinic of the University of Chieti-Pescara, Italy. Forty healthy individuals will be enrolled in this study. In the same session in one randomly selected eye of each subject three consecutive measurements of foveal thickness will be performed using both TD OCT and FD OCT. All measurements will be obtained by the same experienced examinator. Time domain optical coherence tomography images will be obtained from each eye after pupil dilation using the Stratus OCT system (version 4.1. Carl Zeiss Meditec, Dublin, CA). Spectral domain optical coherence tomography images will be obtained using the HRA-OCT Spectralis unit (Heidelberg Engineering GmbH, Heidelberg, Germany). All data will be analyzed with the statistical package MedCalc® version 8.1 for Windows (MedCalc®, Mariakerke, Belgium). The D'Agostino-Pearson test that computes a single P-value for the combination of the coefficients of Skewness and Kurtosis will be used to study the sample distribution. T-test will be used to compare means between Stratus and Spectralis measurements and orizontal and vertical measurements. To assess agreement between Spectralis and Stratus OCT foveal measurements the Bland and Altman plots of the agreement in foveal thickness will be used. For both orizontal and vertical foveal measurements the ratio (Spectralis/stratus OCT foveal thickness) will be plotted against the average of the two measurements.

Interventions

OTHERoptical coherence tomography foveal thickness measurement

In the same session in one randomly selected eye of each subject three consecutive measurements of foveal thickness were performed using both time-domain OCT and spectral-domain OCT.

Sponsors

G. d'Annunzio University
Lead SponsorOTHER

Study design

Observational model
COHORT
Time perspective
CROSS_SECTIONAL

Eligibility

Sex/Gender
ALL
Age
19 Years to 30 Years
Healthy volunteers
Yes

Inclusion criteria

* healthy subjects

Exclusion criteria

* any systemic or eye disease * previous ocular surgery or laser treatment * any systemic or ocular therapy

Design outcomes

Primary

MeasureTime frame
foveal thicknessat subject enrollment

Countries

Italy

Contacts

Primary ContactPaolo Carpineto, M.D.
p.carpineto@unich.it+39 0871 358489
Backup ContactMario Nubile, M.D.
m.nubile@unich.it+39 0871 358489

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026