CRM and Fusion Beats: Effects of Progressive Fusion on Intra-left Ventricular Mechanical Function

CRM and Fusion Beats: Effects of Progressive Fusion on Intra-left Ventricular Mechanical Function

Status
Completed
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT00610896
Enrollment
25
Registered
2008-02-08
Start date
2008-01-31
Completion date
2010-09-30
Last updated
2011-09-02

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Cardiomyopathy

Brief summary

This study is looking at cardiac rhythm management (CRM) and fusion beats in patients who have a pacemaker or implantable cardioverter-defibrillator (ICD), to determine if there is a correlation between the time between the contraction of the upper chambers of the heart (atrium) and the lower chambers of the heart, (ventricle) and heart function. Some studies of people with pacemakers have been done to determine if shortening the time of contraction between the atrium and ventricle could benefit the function of the left ventricle. These studies have shown that there is no benefit in heart function.There have been other studies which have shown that chronic pacing of the right ventricle, especially with the lead placed at the tip of the right ventricle, can lead to a decrease in the function of the left ventricle and congestive heart failure. In some patients long term pacing of the right ventricle has also been associated with a reduction in the ability of the left ventricle to pump blood. This is know as a reduced left ventricular ejection fraction, which can be documented by an echocardiogram. This study proposes to evaluate the acute effects of progressive paced fusion beats on the left ventricle to answer the question whether there is an delay between the atrium and ventricle that is too long or too short.

Interventions

None listed

Sponsors

Essentia Health
Lead SponsorOTHER

Study design

Observational model
COHORT
Time perspective
PROSPECTIVE

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* Dual chamber pacemaker or ICD device * Left Ventrical Ejection Fraction (LVEF) 40% or less * Sinus Rhythm with intact atrioventricular conduction with a PR interval greater than 200 msec QRS less than 120 msec * Pacing right ventricle lead in the right ventricular apex (RVA), system implanted within 6 weeks or chronically implanted system with histograms showing 20% or less right ventricle pacing

Exclusion criteria

* LVEF greater than 40%, * Any rhythm other than sinus rhythm * Second degree or higher atrioventricular block * Native Heart Rate less than 40 beats per minute or greater than 90 beats per minute * Left ventricle or Chronic Sinus lead in non-RVA location * Chronically implanted system with greater than 20% right ventricle pacing

Design outcomes

Primary

MeasureTime frame
Acute effect of mechanical dyssynchrony measured by septal to lateral wall delay using tissue doppler imaging between baseline non-fused atrioventricular conduction and varying degrees of paced and native atrioventricular conduction.

Secondary

MeasureTime frame
Stroke volume as measured by time velocity integral across the aorta valve between baseline non-fused atrioventricular conduction, and varying degrees of paced and native atrioventricular conduction.