Clinical Trial of a Computer-driven Weaning System for Patients Requiring Mechanical Ventilation

A Randomized Controlled Trial of Computer-Driven Weaning Compared With Standard of Care Weaning in Medical Patients Requiring Mechanical Ventilation

Status
Terminated
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT00606554
Enrollment
33
Registered
2008-02-04
Start date
2008-01-31
Completion date
2010-05-31
Last updated
2017-12-11

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Respiratory Insufficiency

Keywords

Respiratory Insufficiency, Ventilators, Mechanical, Ventilator Weaning, Therapy, Computer-Assisted

Brief summary

The purpose of this study is to compare the efficacy of a computer-assisted ventilator weaning system (Drager Smartcare) to our current standard of care in the medical intensive care unit.

Interventions

DEVICEComputer-assisted weaning program

Closed-loop, knowledge-based, computer-assisted wean program initiated at the start of ventilator weaning.

BEHAVIORALStandard of Care weaning

Evidence-based standard of care weaning process.

Sponsors

Boston Medical Center
Lead SponsorOTHER

Study design

Allocation
RANDOMIZED
Intervention model
PARALLEL
Primary purpose
TREATMENT
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* Age greater than 18 years * Initiated on mechanical ventilation via endotracheal tube * Admitted to Medical Intensive Care Unit and Medical Intensive Care Unit Team (Harrison Avenue Campus, Menino Pavilion) * Requiring mechanical ventilation for more than 48 hours * Meets prespecified weaning criteria

Exclusion criteria

* Do Not Resuscitate/Do Not Intubate order * Pregnancy * Mechanical ventilation initiated at another hospital * Cardiac arrest for more than 5 minutes with poor neurologic prognosis * Tracheostomy

Design outcomes

Primary

MeasureTime frameDescription
Duration of WeaningContinuous (median weaning duration was 2 days)Duration of weaning was assessed as the time from the initiation of weaning (randomization) to the time of successful extubation (defined as 48 hours free of mechanical ventilation). Patients were followed for the duration of hospitalization and the time of weaning onset and successful liberation from the ventilator was noted.

Secondary

MeasureTime frameDescription
Duration of Mechanical Ventilationfrom start of weaning to liberation from ventilator, on average 1-2 daysDuration of mechanical ventilation from weaning initiation
Duration of Hospitalizationfrom start of weaning to discharge from hospital, on average 1-2 weeks
Inpatient Mortality28 daysproportion of patients in each arm who died in the hospital
Duration of ICU Stayfrom start of weaning to discharge from ICU, on average 1-2 weeksDuration of ICU stay after weaning initiation
Number of Spontaneous Breathing Trials Prior to Extubationfrom start of weaning to liberation from ventilator, on average 1-2 days
Complications (Death During Wean, Ventilator-associated Pneumonia During Wean, Self Extubation, Re-intubation)Duration of weaning (median 2 days)This outcome is a composite outcome of the total number of participants with any one of the above-listed weaning-associated complications.
Sedation Requirementsduring weaning, on average 1-2 daysmeasure was not recorded

Countries

United States

Participant flow

Recruitment details

Recruitment start 1/2008 recruitment end: 5/2010 Recruited from Medical Intensive Care Unites Boston medical Center

Participants by arm

ArmCount
Computer-assisted Wean
Group assigned to the computer-assisted weaning program Intervention Group
15
Standard of Care
Group assigned to receive current, evidence-based, standard of care for discontinuation of mechanical ventilation. Comparator group
18
Total33

Baseline characteristics

CharacteristicComputer-assisted WeanStandard of CareTotal
Age, Continuous50 years
STANDARD_DEVIATION 21
60.5 years
STANDARD_DEVIATION 15.5
55.7 years
STANDARD_DEVIATION 18.9
APACHE II Score23.3 score
STANDARD_DEVIATION 7.7
26.5 score
STANDARD_DEVIATION 7.1
25 score
STANDARD_DEVIATION 7.4
Sex: Female, Male
Female
5 Participants7 Participants12 Participants
Sex: Female, Male
Male
10 Participants11 Participants21 Participants

Adverse events

Event typeEG000
affected / at risk
EG001
affected / at risk
deaths
Total, all-cause mortality
1 / 156 / 18
other
Total, other adverse events
1 / 150 / 18
serious
Total, serious adverse events
7 / 158 / 18

Outcome results

Primary

Duration of Weaning

Duration of weaning was assessed as the time from the initiation of weaning (randomization) to the time of successful extubation (defined as 48 hours free of mechanical ventilation). Patients were followed for the duration of hospitalization and the time of weaning onset and successful liberation from the ventilator was noted.

Time frame: Continuous (median weaning duration was 2 days)

Population: ITT

ArmMeasureValue (MEDIAN)
Computer-assisted WeanDuration of Weaning1.92 Days
Standard of CareDuration of Weaning2.15 Days
p-value: 0.6Wilcoxon (Mann-Whitney)
Secondary

Complications (Death During Wean, Ventilator-associated Pneumonia During Wean, Self Extubation, Re-intubation)

This outcome is a composite outcome of the total number of participants with any one of the above-listed weaning-associated complications.

Time frame: Duration of weaning (median 2 days)

Population: Number of participants with adverse event during weaning

ArmMeasureValue (NUMBER)
Computer-assisted WeanComplications (Death During Wean, Ventilator-associated Pneumonia During Wean, Self Extubation, Re-intubation)7 Participants
Standard of CareComplications (Death During Wean, Ventilator-associated Pneumonia During Wean, Self Extubation, Re-intubation)8 Participants
p-value: 0.9Chi-squared
Secondary

Duration of Hospitalization

Time frame: from start of weaning to discharge from hospital, on average 1-2 weeks

ArmMeasureValue (MEDIAN)
Computer-assisted WeanDuration of Hospitalization19.1 days
Standard of CareDuration of Hospitalization19.7 days
Secondary

Duration of ICU Stay

Duration of ICU stay after weaning initiation

Time frame: from start of weaning to discharge from ICU, on average 1-2 weeks

ArmMeasureValue (MEDIAN)
Computer-assisted WeanDuration of ICU Stay10.2 days
Standard of CareDuration of ICU Stay15 days
Secondary

Duration of Mechanical Ventilation

Duration of mechanical ventilation from weaning initiation

Time frame: from start of weaning to liberation from ventilator, on average 1-2 days

ArmMeasureValue (MEDIAN)
Computer-assisted WeanDuration of Mechanical Ventilation1.91 days
Standard of CareDuration of Mechanical Ventilation2.15 days
Secondary

Inpatient Mortality

proportion of patients in each arm who died in the hospital

Time frame: 28 days

Population: ITT

ArmMeasureValue (NUMBER)
Computer-assisted WeanInpatient Mortality1 Participants
Standard of CareInpatient Mortality6 Participants
p-value: 0.06Chi-squared
Secondary

Number of Spontaneous Breathing Trials Prior to Extubation

Time frame: from start of weaning to liberation from ventilator, on average 1-2 days

ArmMeasureValue (MEDIAN)
Computer-assisted WeanNumber of Spontaneous Breathing Trials Prior to Extubation0 SBTs
Standard of CareNumber of Spontaneous Breathing Trials Prior to Extubation1 SBTs
Secondary

Sedation Requirements

measure was not recorded

Time frame: during weaning, on average 1-2 days

Population: Data were not recorded

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026