Skip to content

Intraoperative M-Entropy Measurements

Same-patient Reproducibility of Intraoperative M-Entropy Measurements

Status
Completed
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT00599066
Enrollment
24
Registered
2008-01-23
Start date
2007-09-30
Completion date
2009-04-30
Last updated
2017-04-14

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

General Anesthesia

Keywords

M-Entropy

Brief summary

The purpose of this study is to learn more about an Entropy monitor that the anesthesiologist will be using.

Detailed description

Depth of anesthesia monitors are increasingly used in clinical anesthesia practice. Bispectral Index (BIS) and M-Entropy are examples to these devices, both of which are available at our institution. Both BIS and M-Entropy use a unilateral, single channel of EEG to derive a number indicating the anesthetic depth. These devices have similar disposable skin probes that can be applied on either side of the forehead. Since the depth of anesthesia for an individual is the same over the whole brain cortex at a given point in time, BIS numbers obtained over the left and right side of the forehead should agree. The same should be true for M-Entropy as well. A recent study, however, showed that two separate BIS probes, applied over the left and right forehead of the same patient at the same time, can give significantly different numbers. This has not been studied for M-Entropy. BIS and M-Entropy use different mathematical algorithms that process the raw EEG signal to compute a numeric value. Therefore, it is possible that M-Entropy may show different results in a similar study setup. The aim is to investigate the same-patient reproducibility of M-Entropy by monitoring and recording Entropy variables over both the left and the right side of the forehead of patients under general anesthesia.

Interventions

DEVICEstudy cases

Application of a second M-Entropy probe on the forehead of the patient, which will happen in the OR along with the application of other monitors immediately before induction of general anesthesia.

Sponsors

University of Oklahoma
Lead SponsorOTHER

Study design

Observational model
CASE_ONLY
Time perspective
PROSPECTIVE

Eligibility

Sex/Gender
ALL
Age
18 Years to 90 Years
Healthy volunteers
No

Inclusion criteria

* Patients scheduled to have surgery under general anesthesia, with a minimum of 60 minutes expected duration.

Exclusion criteria

* Non-English speaker * Patients younger than 18 years of age

Design outcomes

Primary

MeasureTime frame
The investigators hypothesize that simultaneous M-Entropy measurements from the left and right side of the forehead of a person do not differ during general anesthesia.1 year

Countries

United States

Outcome results

None listed