Skip to content

Cap-fitted Colonoscopy: a Randomized, Tandem Colonoscopy Study of Adenoma Miss Rates

Cap-fitted Colonoscopy: a Randomized, Tandem Colonoscopy Study of Adenoma Miss Rates

Status
Completed
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT00577083
Enrollment
100
Registered
2007-12-19
Start date
2006-11-30
Completion date
2009-10-31
Last updated
2018-12-10

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Polyps

Keywords

miss rates

Brief summary

This is a test in which a thin, black, flexible tube with a lighting system on the end is passed through the anus, into the rectum, in order to examine the large bowel or intestine, also called the colon. Colonoscopy is a very good test for examining the colon for polyps (warty growths that can turn into cancer), but it is not perfect. In fact, about 30% of polyps that are under 5 mm (about 1/5 of an inch) in size are missed during colonoscopy because they are hiding behind folds and bends in the colon. This research study is being done to determine if performing colonoscopy with a cap on the tip of the colonoscope will reduce the miss rate for polyps. A cap is a clear plastic hood that fits on the tip of the colonoscope and sticks out about 1/3 of an inch. During colonoscopy, the cap can be pressed against a fold or ridge in order to flatten it, so that the lining on the other side can be more easily seen. This may reduce the miss rate for colon polyps.

Detailed description

Patient will undergo tandem colonoscopy on the same day using propofol sedation. Patients will undergo one colonoscopy without the cap and a second colonoscopy with the cap on. We will endeavor to keep the total examination time equal between the groups and approximately six minutes. The order in which patients receive the two colonoscopies (i.e. cap or without cap first) will be randomized. Any polyps detected during the first colonoscopy will be removed during that procedure. During the withdrawal phase, the time for examination will be measured with a stopwatch, and the stopwatch will be stopped at any time a polyp is located and restarted when the polyp has been removed and retrieved. The stopwatch will also be stopped for suctioning fluid or washing debris from the colon surface. Any polyp detected and removed during the first colonoscopy will be counted as the detection for that procedure. During the second colonoscopy, all polyps will also be removed when detected. Any polyp identified and removed during the second procedure will be counted as a miss for the first procedure. All polyps will be sent separately for pathologic evaluation. The time required to remove and retrieve polyps with and without the cap on will be measured using a stopwatch as a secondary end point. The primary end point will be the miss rate for colonoscopy with the cap and colonoscopy without the cap.

Interventions

DEVICECap-fitted colonoscopy

Subjects will be randomized to either initial cap-fitted colonoscopy or regular colonoscopy. Patients in the initial regular arm, will undergo cap-fitted colonoscopy for their second, tandem examination. Patients in the initial cap-fitted arm, will under undergo regular colonoscopy (without the cap) for their second, tandem examination.

Sponsors

Indiana University
Lead SponsorOTHER

Study design

Allocation
RANDOMIZED
Intervention model
CROSSOVER
Primary purpose
SCREENING
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
50 Years to No maximum
Healthy volunteers
Yes

Inclusion criteria

* 50 years of age or older, undergoing scheduled colonoscopy and able to give informed consent.

Exclusion criteria

* Previous surgical resection of the colon or rectum * American Society of Anesthesiology class III or higher * Inflammatory bowel disease * Current use of anticoagulants.

Design outcomes

Primary

MeasureTime frameDescription
Number of Adenomasafter the second colonoscopy is completedCap Fitted Colonoscopy (CFC) may significantly reduced miss rates for colorectal adenomas, specifically for small adenomas. This study is the first North American study of any design and the largest tandem study of CFC. CFC is a safe, simple, and inexpensive technology that could improve the reliability of colonoscopy in detecting colorectal neoplasia. Additional study of CFC in Western populations is warranted.

Secondary

MeasureTime frameDescription
Time for Examination Will be Measured With a Stopwatch, and the Stopwatch Will be Stopped at Any Time a Polyp is Located and Restarted When the Polyp Has Been Removed and Retrieved.after 2nd colonoscopy was completed in 24hrsDuring the second colonoscopy, all polyps will also be removed when detected. Any polyp identified and removed during the second procedure will be counted as a miss for the first procedure. All polyps will be sent separately for pathologic evaluation. The time required to remove and retrieve polyps with and without the cap on will be measured using a stopwatch as a secondary end point. The primary end point will be the miss rate for colonoscopy with the cap and colonoscopy without the cap.

Countries

United States

Participant flow

Participants by arm

ArmCount
No Cap First, Then Cap Fitted
no cap on the end of the colonoscope for the first insertion Cap-fitted colonoscopy: Subjects will be randomized to either initial cap-fitted colonoscopy or regular colonoscopy. Patients in the initial regular arm, will undergo cap-fitted colonoscopy for their second, tandem examination. Patients in the initial cap-fitted arm, will under undergo regular colonoscopy (without the cap) for their second, tandem examination.
48
Initial Cap-fitted First Then No Cap
Initial cap-fitted colonoscopy for the first insertion Cap-fitted colonoscopy: Subjects will be randomized to either initial cap-fitted colonoscopy or regular colonoscopy. Patients in the initial regular arm, will undergo cap-fitted colonoscopy for their second, tandem examination. Patients in the initial cap-fitted arm, will under undergo regular colonoscopy (without the cap) for their second, tandem examination.
52
Total100

Baseline characteristics

CharacteristicNo Cap First, Then Cap FittedInitial Cap-fitted First Then No CapTotal
Age, Categorical
<=18 years
0 Participants0 Participants0 Participants
Age, Categorical
>=65 years
0 Participants0 Participants0 Participants
Age, Categorical
Between 18 and 65 years
48 Participants52 Participants100 Participants
Region of Enrollment
United States
48 participants52 participants100 participants
Sex: Female, Male
Female
19 Participants24 Participants43 Participants
Sex: Female, Male
Male
29 Participants28 Participants57 Participants

Adverse events

Event typeEG000
affected / at risk
EG001
affected / at risk
deaths
Total, all-cause mortality
— / —— / —
other
Total, other adverse events
0 / 00 / 0
serious
Total, serious adverse events
0 / 00 / 0

Outcome results

Primary

Number of Adenomas

Cap Fitted Colonoscopy (CFC) may significantly reduced miss rates for colorectal adenomas, specifically for small adenomas. This study is the first North American study of any design and the largest tandem study of CFC. CFC is a safe, simple, and inexpensive technology that could improve the reliability of colonoscopy in detecting colorectal neoplasia. Additional study of CFC in Western populations is warranted.

Time frame: after the second colonoscopy is completed

ArmMeasureGroupValue (NUMBER)
Initial Cap-fittedNumber of AdenomasNumber of adenomas detected at first colonoscopy83 First Colonoscopy number of adenomas
Initial Cap-fittedNumber of AdenomasNumber of adenomas detected at second colonoscopy28 First Colonoscopy number of adenomas
Initial RegularNumber of AdenomasNumber of adenomas detected at first colonoscopy89 First Colonoscopy number of adenomas
Initial RegularNumber of AdenomasNumber of adenomas detected at second colonoscopy44 First Colonoscopy number of adenomas
Secondary

Time for Examination Will be Measured With a Stopwatch, and the Stopwatch Will be Stopped at Any Time a Polyp is Located and Restarted When the Polyp Has Been Removed and Retrieved.

During the second colonoscopy, all polyps will also be removed when detected. Any polyp identified and removed during the second procedure will be counted as a miss for the first procedure. All polyps will be sent separately for pathologic evaluation. The time required to remove and retrieve polyps with and without the cap on will be measured using a stopwatch as a secondary end point. The primary end point will be the miss rate for colonoscopy with the cap and colonoscopy without the cap.

Time frame: after 2nd colonoscopy was completed in 24hrs

Population: Patients aged 50 years or older who were able to give informed consent and were scheduled for elective colonoscopy at IUH were eligible for enrollment. Exclusion criteria were American Society of Anesthesiologists class III or higher, previous surgical resection of the colon or rectum, inflammatory bowel disease, and current use of anticoagulants.

ArmMeasureValue (MEAN)Dispersion
Initial Cap-fittedTime for Examination Will be Measured With a Stopwatch, and the Stopwatch Will be Stopped at Any Time a Polyp is Located and Restarted When the Polyp Has Been Removed and Retrieved.3.1 MinutesStandard Error 0.2
Initial RegularTime for Examination Will be Measured With a Stopwatch, and the Stopwatch Will be Stopped at Any Time a Polyp is Located and Restarted When the Polyp Has Been Removed and Retrieved.3.2 MinutesStandard Error 0.2
Inspection Times (Standard)Time for Examination Will be Measured With a Stopwatch, and the Stopwatch Will be Stopped at Any Time a Polyp is Located and Restarted When the Polyp Has Been Removed and Retrieved.7.0 MinutesStandard Error 0.1
Inspection Times (Cap-Fitted)Time for Examination Will be Measured With a Stopwatch, and the Stopwatch Will be Stopped at Any Time a Polyp is Located and Restarted When the Polyp Has Been Removed and Retrieved.7.0 MinutesStandard Error 0.1
Total Procedure Time (Cap-Fitted)Time for Examination Will be Measured With a Stopwatch, and the Stopwatch Will be Stopped at Any Time a Polyp is Located and Restarted When the Polyp Has Been Removed and Retrieved.18.1 MinutesStandard Error 0.8
Total Procedure Time (Standard)Time for Examination Will be Measured With a Stopwatch, and the Stopwatch Will be Stopped at Any Time a Polyp is Located and Restarted When the Polyp Has Been Removed and Retrieved.20.5 MinutesStandard Error 1.2

Source: ClinicalTrials.gov · Data processed: Mar 31, 2026