Skip to content

Evaluation of Multiple Needle Use in EUS-FNA for Pancreatic Cancer

EMUNE-07 Evaluation of Multiple Needle Use in EUS-FNA for Pancreatic Cancer

Status
Completed
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT00548626
Acronym
EMUNE-07
Enrollment
47
Registered
2007-10-24
Start date
2007-10-31
Completion date
2015-11-30
Last updated
2015-12-21

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Pancreatic Cancer

Keywords

Pancreatic Cancer, Endoscopic Ultrasonography, Fine-Needle Aspiration, Cytopathology

Brief summary

The aim of this study is to evaluate if the early change of needle during EUS-FNA for suspected pancreatic cancer allows an earlier preliminary cytological diagnosis of neoplasia.

Detailed description

This is a prospective randomized controlled trial which will recruit patients referred for suspicion of pancreatic mass and indication of EUS-FNA as part of standard of care in the Interventional Endoscopy Unit at the University Of Chicago Medical Center. Basic demographic data will be recorded for each patient. If a pancreatic mass is confirmed in EUS evaluation the patient will be randomized in a 1:1 ratio to either Control group (Single needle) or Investigational group (Multiple Needle). There will be an expert cytopathologist in the exploration room (blinded to the group assignment). Samples obtained through FNA will be prepared onsite either for cytological evaluation by the cytopathologist: each fine needle sample will be expressed by using a 10mL air-filled syringe onto a separate glass slide, and a direct smear will be made by an on-site cytopathologist. Each slide will be air-dried and/or alcohol fixed (95% ethanol), and direct smears will be prepared for immediate interpretation by staining with Diff-quick staining system. Patients assigned to simple needle group (SN) will be sampled for a total of 6 consecutive FNA passes with a single EUS-FNA needle (only replaced if the needle has a reduced performance). After completing the 6th pass the endoscopist will be informed by the onsite cytopathologist about the preliminary cytological diagnosis. Patients assigned to multiple needle group (MN) will be sampled for a total of 6 consecutive FNA passes, replacing the needle after every 2 passes. After completing the 6th pass the endoscopist will be informed by the onsite cytopathologist about the preliminary cytological diagnosis. A cytopathologist (#1) will be present during each EUS-FNA procedure to prepare the slides and determine whether each specimen was adequately cellular. After the procedure, all the cytological samples will be sent to the Pathology department in order to complete the study. A cytopathologist (#2) not present during the procedure will study all the sampling specimens obtained during the EUS-FNA procedure and produce the final and definitive cytopathological diagnosis. Criteria for pancreatic cancer and benign pancreatic lesions will be defined. Follow-up of all patients to assess early and late complications will be carried out for 30 days after the procedure. Endpoints: 1. Primary endpoint: Evaluate if the early change of needle during EUS-FNA for suspected pancreatic cancer can reduce the number of passes needed to obtain a preliminary cytological diagnosis of neoplasia. We hypothesized that the number of passes needed using the multiple needles will be significantly less than that using the single needle. 2. Secondary endpoints: * Rate of complications related with EUS-FNA * Influence of different factors in obtaining a positive cytological result (histological differentiation)

Interventions

PROCEDURESingle needle

Patients will be sampled for a total of 6 consecutive FNA passes with a single EUS-FNA needle (only replaced if the needle has a reduced performance). After completing the 6th pass the endoscopist will be informed by the onsite cytopathologist about the preliminary cytological diagnosis.

PROCEDUREMultiple needle

Patients will be sampled for a total of 6 consecutive FNA passes, replacing the needle after every 2 passes. After completing the 6th pass the endoscopist will be informed by the onsite cytopathologist about the preliminary cytological diagnosis.

Sponsors

Cook Group Incorporated
CollaboratorINDUSTRY
University of Chicago
Lead SponsorOTHER

Study design

Allocation
RANDOMIZED
Intervention model
PARALLEL
Primary purpose
DIAGNOSTIC
Masking
SINGLE (Subject)

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* Suspicion of pancreatic mass due to previous exam/s (CT, MR, ERCP, US, …) that requires EUS-FNA in order to complete diagnosis * Age ≥ 18 y/o * Formal informed consent * No previous chemotherapy or radiotherapy * No previous pancreatic surgery

Exclusion criteria

* Any patient unable to understand the procedure, nature of the current study, or sign a consent form.

Design outcomes

Primary

MeasureTime frame
Evaluate if the early change of needle during EUS-FNA for suspected pancreatic cancer can reduce the number of passes needed to obtain a preliminary cytological diagnosis of neoplasia.October 2007- September 2008

Secondary

MeasureTime frame
Rate of complications related with EUS-FNAOctober 2007- September 2008
Influence of different factors in obtaining a positive cytological resultOctober 2007- September 2008

Countries

United States

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026