Skip to content

Internal Jugular Vein Ultrasound Measures and Fluid Responsiveness in Post-Operative Cardiac Surgical Patients

Do Internal Jugular Vein Measurements Made By Ultrasound Correlate With Fluid Responsiveness in Ventilated Post-Operative Cardiac Surgical Patients?

Status
Completed
Phases
Phase 1
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT00500981
Enrollment
40
Registered
2007-07-13
Start date
2007-06-30
Completion date
2008-12-31
Last updated
2012-07-26

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Cardiac Surgical Procedures, Fluid Therapy

Keywords

Fluid responsiveness

Brief summary

The goal of this study is to evaluate whether measures of the size of the internal jugular vein have clinical utility in predicting whether patients may benefit from treatment with intravenous fluid.

Detailed description

The optimal therapy for numerous disease states involves the replenishment of intravascular volume. Unfortunately, our current clinical measures of volume status are imperfect. Given biologic plausibility and preliminary study, it is possible that static and/or dynamic measures of internal jugular vein (IJV) size may correlate with volume status and/or be associated with volume responsiveness. If so, this type of assessment might be a more ideal clinical volume-assessment tool. This pilot study aims to establish proof of concept via evaluation of this question in patients following cardiac surgery. This is a prospective observational study of physiologically-stable, ventilated patients post-cardiac surgery. The primary objective of this study is to evaluate the relationship between the static size of the right IJV and fluid responsiveness in ventilated post-operative cardiac surgical patients. A secondary objective is to evaluate the relationship between dynamic variations in the size of the right IJV related to respiration and leg-raising and fluid responsiveness in the same group. Static and dynamic ultrasound measurements of the right IJV will be performed pre-volume challenge. Volume responsiveness will be independently assessed by cardiac index measurement before and after rapid infusion of 10% pentastarch. 30 subjects will be recruited pre-operatively and informed consent obtained. Stability of sedation, mechanical ventilation, and hemodynamics will be assured prior to initiation of measurements. Baseline static and respiratory dynamic ultrasound measurements of the right IJV will be obtained and then repeated after bilateral leg-raising. Baseline hemodynamics and cardiac outputs will be obtained using indwelling pulmonary artery catheters. A standardized volume challenge of 10% pentastarch given over 15 minutes will then be provided followed by repeat hemodynamic and cardiac output measurements. Offline measurements of IJV size will be obtained from unmodified stored video loops by a single observer blinded to patient identity, hemodynamic, and fluid response data. Fluid responsiveness will be assessed by examining the change in cardiac index after volume challenge with a fluid responsive state defined as an increase of ≥ 12 % of cardiac index after volume challenge. The relationship between volume responsiveness and IJ ultrasound measures will be evaluated continuously and dichotomously.

Interventions

PROCEDUREUltrasound evaluation of internal jugular vein

Sponsors

Department of Critical Care Medicine
CollaboratorUNKNOWN
University of Calgary
Lead SponsorOTHER

Study design

Allocation
NA
Intervention model
SINGLE_GROUP
Primary purpose
DIAGNOSTIC
Masking
SINGLE (Outcomes Assessor)

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* Adults (\>18 years old) * Able to provide advanced informed consent * Planned elective or semi-urgent cardiac surgery

Exclusion criteria

* Severe tricuspid regurgitation or planned tricuspid valve surgery * Congenital heart disease associated with cardiac shunting * Pre or post-operative presence of an intra-aortic balloon pump * Severe chronic obstructive pulmonary disease * Hemodynamic instability such that inotropes/vasopressor dosing is not constant * Respiratory instability and/or need for PEEP \> 5 cmH20

Design outcomes

Primary

MeasureTime frame
To evaluate the relationship between the static size of the right IJV and fluid responsiveness in ventilated post-operative cardiac surgical patients.1 hour

Secondary

MeasureTime frame
To evaluate the relationship between dynamic variations in the size of the right IJV related to respiration and leg-raising and fluid responsiveness in ventilated post-operative cardiac surgical patients.1 hour

Countries

Canada

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026