Skip to content

Titanium-Sapphire Laser Trabeculoplasty in Glaucoma: A Randomized Study Comparing Titanium-Sapphire With Argon Laser Trabeculoplasty in Open-Angle Glaucoma Patients

Status
Completed
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT00470964
Enrollment
Unknown
Registered
2007-05-08
Start date
Unknown
Completion date
Unknown
Last updated
2007-05-08

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Glaucoma, Open-Angle

Keywords

laser trabeculoplasty, glaucoma, argon, titanium-sapphire, IOP lowering effect, Adverse effects, IOP spikes

Brief summary

Titanium Sapphire laser trabeculoplasty is effective in lowering intraocular pressure in glaucoma patients, and is comparable to argon laser trabeculoplasty

Detailed description

Objective: To compare the medium-term outcome of Titanium-Sapphire laser trabeculoplasty (TiSLT) vs. Argon Laser Trabeculoplasty (ALT) in uncontrolled Open-angle Glaucoma (OAG) patients. Methods: Prospective, masked, randomized comparative clinical study. Thirty-seven OAG patients with uncontrolled IOP and no previous filtration surgery (22 females and 15 males, mean age of 68 years) participated. Eighteen were treated with TiSLT and 19 with ALT. All patients underwent a comprehensive eye examination including visual acuity, IOP, goniocscopy and slit-lamp biomicroscopy and visual field examinations. Patients were examined pre-operatively and then at 1 hour, 1 day, 1 week, 1, 3 and 6 months, 1 year and 18 months post-operatively. Main outcome measures: Final IOP, delta IOP and number of anti-glaucoma medications. Results: The 18 patients in the TiSLT arm had an average of 8.3(±2.7) mm Hg or 32% reduction from pre-operative IOP (P\<0.001). The 19 patients in the ALT arm had a mean IOP decrease of 6.5 (±4.3) mm Hg (P\<0.001) or a 25% IOP reduction. Patients in both groups achieved a similar decrease in IOP (P\>0.05). TiSLT patients had statistically significant fewer IOP spikes compared to the ALT group. (P=0.002). Two patients (1 in each arm) underwent trabeculectomy and were considered failures. Mean follow-up time was 15 months. Conclusions: TiSLT provides similar efficacy to ALT in IOP reduction in OAG patients, and may offer better safety with fewer IOP spikes see post-operatively. Application to clinical practice: If confirmed in additional studies, TiSLT may be used as an alternative to ALT in OAG patients.

Interventions

PROCEDURETitanium Sapphire laser trabeculoplasty

Sponsors

Goldschleger Eye Institute
Lead SponsorOTHER

Study design

Allocation
RANDOMIZED
Intervention model
PARALLEL
Masking
DOUBLE

Eligibility

Sex/Gender
ALL
Age
40 Years to 91 Years
Healthy volunteers
No

Inclusion criteria

* Uncontrolled open angle glaucoma patients

Design outcomes

Primary

MeasureTime frame
IOP

Countries

Israel

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026