Correlation BIS Scores Mentally Retarded Patients

Correlation Between the Severity of Mental Retardation and BIS in Mentally Retarded Patients Undergoing Dental Rehabilitation

Status
Completed
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT00468338
Enrollment
90
Registered
2007-05-02
Start date
2006-12-31
Completion date
2008-05-31
Last updated
2016-11-01

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Mental Retardation

Keywords

general anesthesia, dental rehabilitation, mental retardation

Brief summary

The BIS monitor is a tool which assists anesthesiologists in monitoring the depth of anesthesia or level of anesthesia. The study doctors would like to see if it is useful tool for patients who are mentally challenged and require anesthesia.

Detailed description

General endotracheal tube anesthesia (GETA) is administered for mentally retarded patients that need dental rehabilitation. GETA is done, in all patients, with routine monitoring of electrocardiography, blood pressure recording, pulse oximetry and end-tidal capnography. These measurements are also used indirectly to determine the depth of anesthesia and the anesthetic is titrated to prevent awareness during surgery and any subsequent recall (1). In addition, a recently introduced functional electroencephalography (EEG)-based awareness monitor directly analyzes the brain wave pattern during anesthetic delivery and aids the anesthesiologist in maintaining the ideal depth of anesthesia. The EEG based monitor serves to prevent awareness and recall due to light anesthesia or prolonged recovery following deep anesthesia (2). This instrument, named the Bispectral Index Scale (BIS) monitor, is non-invasive and is approved by the Food & Drug Administration. However, the BIS monitor is not being used routinely during the anesthetic management of mentally retarded patients due to a belief that such monitoring would be inaccurate in this cohort of patients (3). This assumption lacks scientific validation. Our trial will investigate the usefulness of BIS monitoring in mentally retarded patients and document any correlation between the severity of mental retardation and BIS scoring during various phases of anesthesia, such as awake status and sedation prior to anesthesia, induction and maintenance of anesthesia, and emergence and recovery from anesthesia. The anesthetic protocol will be standardized and the anesthetic management will not deviate from routine practice. The adjuvant therapies for infection prophylaxis and pain control will be administered in the usual fashion.

Interventions

BIS monitor measures the depth of anesthesia and was used in the entire group

Sponsors

Rutgers, The State University of New Jersey
Lead SponsorOTHER

Study design

Observational model
CASE_ONLY
Time perspective
PROSPECTIVE

Eligibility

Sex/Gender
ALL
Age
12 Years to 65 Years
Healthy volunteers
No

Inclusion criteria

* mentally retarded persons ages 12 to 65 undergoing dental rehabilitation

Exclusion criteria

* patients who are pregnant parents/and or legal guardians who do not wish to give consent