Minimally-invasive Assessment of Cardiac Output in Severe Preeclampsia

Minimally-invasive Assessment of Cardiac Output in Severe Preeclampsia: Radial Artery Wave Form Analysis Versus Trans-thoracic Echocardiogram

Status
Withdrawn
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT00465114
Enrollment
0
Registered
2007-04-24
Start date
2007-04-30
Completion date
2007-12-31
Last updated
2018-02-06

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Preeclampsia

Keywords

Preeclampsia, Hemodynamic monitoring

Brief summary

Severe preeclampsia often presents with uncontrolled hypertension and therefore requires close monitoring of blood pressure and cardiac performance. The purpose of the study is to compare two methods of measuring the performance of the heart in pregnant women: one by ultrasound of the heart, the other by assessing the pulse generated in the blood vessel of the wrist. We hope that the method using pulse analysis will be as effective as ultrasound, which is labour intensive and operator dependant.

Detailed description

Severe preeclampsia often presents with uncontrolled hypertension, which requires close monitoring of blood pressure and cardiac output. It will be very useful to know the cardiac output in this patient population, because it will guide the choice of antihypertensive drugs and measure their effect on cardiac output. Traditionally pulmonary artery catheters were used to measure cardiac output. There are numerous problems with using this method in severe preeclampsia. These include technical difficulty inserting the catheter in an awake, edematous pregnant patient, potentially causing a pneumothorax, damaging the carotid artery or insertion site infection. There is also an increased risk for cardiac arrhythmias. Apart from the risks, the accuracy of the thermodilution measurements can be influenced by factors such as timing of the injection within the respiratory cycle, temperature of the injectate, speed of injection, and placement of the catheter. A readily available, accurate non-invasive cardiac output measurement technique, that will provide reliable data with fewer risks, is needed. Doppler ultrasound (trans thoracic echocardiography) is the gold standard for measuring cardiac output non-invasively in pregnant patients. Unfortunately the method is operator dependant, not continuous and not always available when needed most. Recently a device called the FloTrac has been introduced that measures cardiac output minimally invasively. Attached to an arterial line it measures cardiac output every 20 seconds via arterial waveform analysis. The standard of care for measuring blood pressure in severe preeclampsia requires the placement of an intra-arterial line. This group of patients is therefore ideal for measuring cardiac output with the FloTrac, especially since powerful intravenous anti-hypertensives are used to control blood pressure. Our hypothesis is that the FloTrac will be comparable to Doppler Ultrasound for measuring cardiac output in severely preeclamptic patients.

Interventions

PROCEDUREHemodynamic Monitoring

Sponsors

Samuel Lunenfeld Research Institute, Mount Sinai Hospital
Lead SponsorOTHER

Study design

Observational model
COHORT
Time perspective
PROSPECTIVE

Eligibility

Sex/Gender
FEMALE
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* Severe Preeclampsia * Arterial Line Required * Candidates for magnesium sulfate, labetalol or hydrazine

Exclusion criteria

* Preexisting cardiac disease

Countries

Canada

Outcome results

None listed