Skip to content

Estimation of Intrinsic Positive End-Expiratory Pressure (PEEP) in Acute Respiratory Distress Syndrome (ARDS)

Estimation of Intrinsic Positive End-Expiratory Pressure (PEEP) in Acute Respiratory Distress Syndrome (ARDS)

Status
Completed
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT00446706
Enrollment
6
Registered
2007-03-13
Start date
2004-01-31
Completion date
2007-04-30
Last updated
2017-05-09

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Acute Respiratory Distress Syndrome

Keywords

Intrinsic PEEP

Brief summary

ARDS (Acute Respiratory Distress Syndrome) is a condition of severe inflammation and excess fluids in the lungs that impairs their function of oxygen uptake to the point of needing a ventilator (breathing machine) to help them obtain enough oxygen into the body. Because of the high amounts of gas that the ventilator has to give to these patients, high pressures may develop deep into the lungs and produce complications for the patient. However, physicians sometimes cannot recognize it because it requires special equipment to measure pressure deep in the lungs. The goal of this study is to determine if the amount of this pressure can be calculated using mathematical formulas and the routine numbers provided by ventilators. The study consists on making the conventional measurement of this deep pressure and at the same time calculate this same pressure from other measurements that the ventilator routinely provides, to see if the calculated value can replace the more complicated conventional measurement. The measurements will be done by: 1. placing a small device along the tubing connecting the patient to the ventilator; 2. giving medicines to relax the muscles (if the patient is not already receiving them); and 3. making the ventilator hold the patient's breath for a few seconds to take measurements. This is repeated after the breathing rate of the ventilator is increased or decreased mildly. Risks related to the medicine to be used and the measuring maneuvers are rare but include transient narrowing of windpipes, transiently low heart rate, blood pressure or blood oxygen, and allergic reactions. This is not a treatment. The information obtained during the study will be shared with the treating doctors who may find it useful to make adjustments to the ventilator. The patient may receive no direct benefit from being in this study; however, the findings may contribute to better care for this kind of patients in the future.

Detailed description

Intrinsic PEEP (Positive-End Expiratory Pressure) was measured by end-expiratory occlusion method and estimated using formulas derived from measured expiratory flows and a postulated linear pressure-flow relationship during expiration in passive ARDS patients. Agreement between measured and estimated intrinsic PEEP was analyzed by Bland and Altman's method.

Interventions

None listed

Sponsors

Texas Tech University Health Sciences Center, El Paso
Lead SponsorOTHER

Study design

Observational model
CASE_ONLY
Time perspective
PROSPECTIVE

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* Patients 18 years of age or older with diagnosis of ARDS, as defined by the American- European Consensus Conference 4 * Receiving mechanical ventilation. * Presence of autoPEEP by inspection of flow-time waveforms displayed by the mechanical ventilator.

Exclusion criteria

* Known or suspected diagnosis of COPD or airflow limitation. * Next of kin not available to consent. * Contraindication to receive a muscle relaxant when measurements may be inaccurate without its administration. * Pregnancy

Design outcomes

Primary

MeasureTime frameDescription
Agreement between Measured and Estimated Intrinsic PEEPThe day and time of measurementBias and its standard deviation

Countries

United States

Outcome results

None listed