Ultrasound Imaging For Facilitating Labour Epidurals in Obese Parturients

Ultrasound Imaging For Facilitating Labour Epidurals in Obese Parturients

Status
Completed
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT00439998
Enrollment
54
Registered
2007-02-26
Start date
2006-10-31
Completion date
2008-02-29
Last updated
2009-07-30

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Obesity

Keywords

Ultrasound, Obesity, Needle Depth

Brief summary

The efficacy of an epidural depends mainly on accurate placement of the catheter in the epidural space. Therefore, identification of the epidural space is the most vital part of the procedure. Obese patients represent the most challenging group for the identification of anatomical landmarks. With the use of ultrasound, we can visualize the images of the anatomical structures in the back. Some anesthesiologists believe ultrasound can help in the placement of an epidural, and routinely use it to assist in determining needle entry point in your back as well as estimating the depth at which the epidural space will be found. Our hypothesis is that the use of lumbar spine ultrasound imaging will accurately determine the epidural space depth and the epidural insertion point in obese patients.

Detailed description

Recent technical advances, especially the evolution of ultrasound technology, have helped to some extent in circumventing some of the limitations of epidural anesthesia. The efficacy of an epidural depends mainly on accurate placement of the catheter in the epidural space. Therefore, identification of the epidural space is the most vital part of the procedure. Obese patients represent are the most challenging group for the identification of anatomical landmarks, it is important to determine if ultrasound imaging is a useful technique in this population. All the patients will undergo ultrasound imaging of the lumbar spine just before epidural insertion. Ultrasound imaging will be performed by one of the investigators. A different anesthesiologist will perform the epidural procedure based on the US information provided by the investigator. The investigator will provide information to the epidural performer on the insertion point, the angle of needle insertion and safe approximate distance before reaching the epidural space to facilitate the epidural performance. To maintain blinding and to prevent performer bias, the exact depth of the epidural space from skin, as seen on the ultrasound will not be disclosed. The investigator, with the aid of an in-built caliper, will measure this distance at a later time before saving the image. The results of this study are expected to determine the clinical reliability of ultrasound imaging in visualizing the anatomical structures relevant to the technical performance of epidural analgesia in the obese population. Since technical difficulty in performing epidurals is more commonly encountered in obese patients, ultrasound visualization would improve the overall success of the technique by predicting the depth of the epidural needle to be inserted. In turn, the complication rate would be minimized.

Interventions

PROCEDUREUltrasound

ultrasound scan of the lumbar spine with 2-5 MHz curved array probe

Sponsors

Samuel Lunenfeld Research Institute, Mount Sinai Hospital
Lead SponsorOTHER

Study design

Allocation
NON_RANDOMIZED
Intervention model
SINGLE_GROUP
Primary purpose
DIAGNOSTIC
Masking
NONE

Eligibility

Sex/Gender
FEMALE
Healthy volunteers
Yes

Inclusion criteria

* Full term pregnant patients requesting labor epidurals * Pre-pregnancy BMI greater than 30

Exclusion criteria

* Known spinal deformities * Previous back instrumentation * Pre-pregnancy BMI less than 30

Design outcomes

Primary

MeasureTime frame
Accuracy of Epidural Depth30 minutes

Secondary

MeasureTime frame
Accuracy of needle angle, re-insertion of the epidural needle in the same interspace or different interspace30 minutes
Correlation between BMI and skin thicknessanalysis at study end, approximately 1 year
Correlation between BMI and needle depthanalysis at study end, approximately 1 year
Duration of ultrasound scanning30 minutes