Skip to content

Interruption of Dorsal Visual Stream Using TMS

Interruption of Dorsal Visual Stream Using TMS in Normal Controls

Status
Completed
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT00418652
Enrollment
12
Registered
2007-01-05
Start date
2006-01-31
Completion date
Unknown
Last updated
2011-08-04

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Healthy

Keywords

Normal Controls

Brief summary

Trans Cranial Magnetic Stimulation (TMS) over dorsal visual system will disturb the ability to identify objects with decreased level of fragmentation

Detailed description

The participants performed two tasks under three different TMS conditions: no TMS, 10Hz TMS for over the dorsal stream (PO3 EEG site) or over the vertex. First they performed a perceptual closure task which asked them to identify an object in a series of six progressively less degraded pictures. Then, they also performed a control task previously shown not to be mediated by the LOC and not to be impaired in schizophrenia: The perception of illusory contours.

Interventions

DEVICENo TMS intervention

In the no TMS condition, no simulation was given and no coil placed near participants' heads.

DEVICETMS over the PO3 EEG site

10Hz TMS over the dorsal stream (PO3 EEG site)

DEVICETMS over the vertex

10Hz TMS for over vertex.

Sponsors

Sheba Medical Center
Lead SponsorOTHER_GOV

Study design

Allocation
RANDOMIZED
Intervention model
SINGLE_GROUP
Primary purpose
DIAGNOSTIC
Masking
SINGLE (Subject)

Eligibility

Sex/Gender
ALL
Age
18 Years to 65 Years
Healthy volunteers
Yes

Inclusion criteria

* Normal controls

Exclusion criteria

* neurological, ophthalmological or psychiatric problems * family history of schizophrenia * left handed

Design outcomes

Primary

MeasureTime frameDescription
Results of the study assignments performed by the participants during the study.The participants performed the tasks once during their study visitThe subjects performed 2 tasks: The primary dependent measures consisted of the level of detail needed for correct object identification, response accuracy, and response time in milliseconds for correct responses. Illusory Contour Task: Subjects also performed a pulsed pedestal task, Participants were shown 55 drawings for 500 ms each. Some drawings contained partial contours which defined a geometric shape, while in others the contours did not define a shape. Participants were asked to indicate whether they recognized a geometric shape or not. Accuracy and response time were measured.

Countries

Israel

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026