Skip to content

Initial Evaluation of Photorefractive Keratectomy in U.S. Army Personnel

Initial Evaluation of Photorefractive Keratectomy in U.S. Army Personnel

Status
Completed
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT00413673
Enrollment
100
Registered
2006-12-20
Start date
2001-08-31
Completion date
2008-03-31
Last updated
2008-04-01

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Myopia

Keywords

Naturally occurring low to moderate myopia, with or without low levels of astigmatism in U.S. Army personnel

Brief summary

The objective of this study is to conduct a prospective clinical trial to evaluate the safety and efficacy fo the VISX Excimer Laser system for the treatment of naturally occurring low to moderate myopia, with or without low levels of astigmatism, in U.S. Army personnel.

Interventions

PROCEDUREPRK

PRK

Sponsors

Walter Reed Army Medical Center
Lead SponsorFED

Study design

Allocation
NON_RANDOMIZED
Intervention model
SINGLE_GROUP
Primary purpose
TREATMENT
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
21 Years to No maximum
Healthy volunteers
Yes

Inclusion criteria

* Informed consent. * Normal, healthy active adults with access to medical care at Walter Reed Health Care System. * Age 21 years or older. * Spherical equivalent of the manifest refractive error between -1.0 to -6.0 diopters (D), inclusive, with no more than 3.0D of cylinder. The absolute value of the cylinder (expressed in minus cylinder) will be limited such that the short axis of the elliptical ablation will be no smaller than 4.9mm. The following specifies the maximum cylinder for a given spherical component of the manifest refraction: Spherical component / Maximum cylinder * 1.0D / -0.5D * 2.0D / -1.0D * 3.0D / -1.5D * 4.0D / -2.0D * 5.0D / -2.5D * 6.0D / -3.0D * Corrected vision of at least 20/20 * Soft contact lens users must havE removed their lenses at least two weeks prior to baseline measurements. * Hard contact lens users (PMMA or rigid gas permeable lenses) must have removed their lenses at least four weeks prior to baseline measurements. At least two weekly manifest refractions and keratometry measurements will be required in this interval. The last two measurements must not vary by more than 0.50D in any meridian. * Patients undergoing orthokeratology must have their lenses removed at least 6 months prior to the baseline examination. At least two monthly manifest refractions and keratometry measurements taken after the third month out of lenses must not vary by more than 0.50D in any meridian. * Refractive stability must be documented by previous refractions. Spherical and cylindrical portion of the manifest refraction must not have varied by more than 0.50D over the previous 12 months. * Exhibits strong motivation for keeping the follow-up visits. * Available for evaluation at Walter Reed during the two-year follow-up period. * Service members must have their command approval to participate in the study. * Access to transportation to meet follow-up requirements.

Exclusion criteria

* Residual, recurrent or active ocular diseases or corneal abnormalities in either eye such as iritis, uveitis, keratoconjunctivitis sicca, herpetic keratitis, vernal conjunctivitis, lagophthalmos, corneal scarring, glaucoma, previous steroid responder, occludable chamber angles, visually significant cataracts. * Either one or both eyes suffering from chronic dryness. * Taking any systemic medications that may affect wound healing such as corticosteroids or antimetabolites. * Patient corneal neovascularization within one mm of the ablation zone. * History of any previous eye surgery, including previous refractive surgery. * Best corrected visual acuity of less than 20/20. * Progressive myopia or keratoconus. * Any systemic disease that may affect wound healing, such as connective tissue disorders (rheumatoid arthritis, systemic lupus erythematosus, etc.), diabetes, or severe atopic disease. * Any physical or mental impairment that would preclude participation in any of the examinations. * For contact lens users there must be no evidence of contact lens corneal warpage on computerized topography. * Currently on flight status or projected to be on flight status within ten years. * Pregnant or breast-feeding an infant. Women of childbearing age must take a urine blood pregnancy test before starting this study

Design outcomes

Primary

MeasureTime frame
safety and efficacy of PRK12 months after surgery

Countries

United States

Outcome results

None listed