Skip to content

A Prospective Randomized Trial Using Roentgen Stereophotogrammetric Analysis of the Advance Medial Pivot Knee

A Prospective Randomized Trial Using Roentgen Stereophotogrammetric Analysis of the Advance Medial Pivot Knee

Status
Completed
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT00405470
Enrollment
80
Registered
2006-11-30
Start date
2001-07-31
Completion date
2006-06-30
Last updated
2010-08-12

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Osteoarthritis, Knee

Keywords

arthroplasty, RSA, micromotion, osteoarthritis

Brief summary

The purpose of this study is to determine whether this particular knee replacement is better than those already on the market. By participation, it will further refine the design of future total knee replacements and perhaps increase longevity.

Detailed description

Joint arthroplasty is an effective surgical intervention, however prosthetic survivorship is finite. New or modified prosthetic components are routinely introduced, partly in an effort to improve survivorship. When new technologies emerge for total knee replacement it is not always evident that they are an improvement over existing options. This determination requires long-term follow-up studies. Conventional studies require a large number of patients and approximately 10 years of follow-up. By using RSA to measure micromotion of prostheses over time problems can be elucidated with a much smaller sample over a shorter time period. RSA involves using tantalum markers (0.5-1.0 mm beads inserted in the bone and prosthesis during surgery) to measure motion in subsequent bi-planar x-rays of the joint. The relatively new Medial Pivot Knee (ADVANCE Knee) theoretically reproduces the natural kinematics of the knee but it is unclear what effect this design may have on the forces applied to the tibial component-bone interface. The amount of micromotion of the tibial component is directly related to the amount of force exerted on it and inversely related to its fixation. In this study we propose to compare in vivo micromotion at the tibial component-bone interface with the ADVANCE Medial-Pivot Knee (experimental group) versus a more conventional prosthesis (control), the ADVANCE Traditional Knee. Patients (n=60; age 45-80 years old) with primary osteoarthritis of the knee and mono-articular disease will be randomized to receive either the ADVANCE Traditional or ADVANCE Medial-Pivot Knee using Simplex cement. Eight tantalum markers will be placed in both the tibia and femur proximal to the prosthesis and in the polyethylene tray of the tibial component. Pre-operatively and at 6, 12 and 24 months all patients will complete general health (SF-12) and joint specific questionnaires (Oxford -12 Item Knee Score), have their body mass index calculated, and have the range of motion, alignment, extensor function and ligamentous competency of their index knee recorded. On the first weight-bearing day after surgery bi-planar standing x-rays will be taken and used as a reference point for tibial component position. At 6, 12 and 24 months post-operatively patients will undergo more bi-planar standing x-rays incorporating provocative loading tests. Micromotion will be analyzed through serial comparison of digital x-rays by blinded study personnel using RSA software. Parametric statistics (unpaired Student's t-test) will be used to compare the 2 groups.

Interventions

DEVICEAdvance Medial Pivot Knee Arthroplasty

medial pivot total knee arthroplasty tibial component vs standard posterior stabilized tibial component with post. Medial pivot provides a constrained medial condyle through shape of polyethylene and reduces amount of bone removal on femoral side that would otherwise be removed to accommodate PS post

Sponsors

Stryker Trauma and Extremities
CollaboratorINDUSTRY
Dalhousie University
Lead SponsorOTHER

Study design

Allocation
RANDOMIZED
Intervention model
PARALLEL
Primary purpose
TREATMENT
Masking
SINGLE (Subject)

Eligibility

Sex/Gender
ALL
Age
45 Years to 80 Years
Healthy volunteers
No

Inclusion criteria

* Primary osteoarthritis of the knee * Mono-articular disease (Charnley Modified Type A)

Exclusion criteria

* Significant co-morbidity affecting ability to ambulate * Flexion contracture greater than 15° * Tibial subluxation greater than 10 mm on standing AP radiograph * Greater than 10° of varus or 15° of valgus * Extension lag greater than 10° * Lateral or medial collateral ligament instability (\> 10° varus/valgus) * Previous osteotomy about the knee * Previous arthroplasty of the knee * Previous patellectomy * Leg length discrepancy greater than 10 mm * Morbid obesity (obesity that results in significant systemic problems)

Design outcomes

Primary

MeasureTime frame
tibial implant micromotion relative to tibia at 2 years2 years postoperative

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026