Skip to content

Manual Administration of Propofol-remifentanil Versus Dual Closed-loop Using Bispectral Index as the Control Variable

Target-controlled Infusion of Propofol and Remifentanil During General Anaesthesia Guided by the Index Bispectral: Comparison Between Manual Perfusion and Automated Perfusion

Status
Completed
Phases
Phase 4
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT00392158
Enrollment
240
Registered
2006-10-25
Start date
2006-02-28
Completion date
2007-04-30
Last updated
2016-09-26

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Anesthesia, General

Brief summary

To compare manual administration of propofol and remifentanil and dual closed-loop using bispectral index as the control variable during anesthesia

Detailed description

The Bispectral Index (BIS) is an electroencephalogram-derived measure of anesthetic depth. A closed-loop anesthesia system can be built using BIS as the control variable, a proportional-integral-differential control algorithm, and a propofol target-controlled infusion system as the control actuator. Recent studies have shown that such system is able to provide clinically adequate anesthesia. We hypothesized that BIS can also indicate the adequacy of analgesia and therefore built a combined closed-loop anesthesia system using BIS as the control variable, two proportional-integral-differential control algorithms, a propofol and a remifentanil target-controlled infusion systems as the control actuators. In preparation for a large multi-center control trial, we propose a prospective randomized study to evaluate the effectiveness of such a closed-loop anesthesia system. Two groups of patients are compared: one in which propofol and remifentanil are administered by the anesthesiologist using target-controlled infusion systems, and one in which propofol and remifentanil are administered automatically by the combined closed-loop anesthesia system. In both groups, the goal is to maintain BIS between 40 and 60, the recommended range during anesthesia by the manufacturer. We expect the combined closed-loop anesthesia system group to do similar or better.

Interventions

Sponsors

Hopital Foch
Lead SponsorOTHER

Study design

Allocation
RANDOMIZED
Intervention model
PARALLEL
Primary purpose
TREATMENT
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* surgery under general anesthesia using relaxant agent, * surgery lasting more than one hour

Exclusion criteria

* pregnant women, * indication for rapid sequence induction, * anticipation of difficult intubation, * allergy to propofol or remifentanil, * neurological or muscular disorder, * combination of general anesthesia and of regional anesthesia, * emergency surgery.

Design outcomes

Primary

MeasureTime frame
Global score (calculated parameter which depicts the performance of the system, i.e. its capacity to maintain BIS in the desired range)

Secondary

MeasureTime frame
number of modifications of target of propofol and remifentanil
number of episodes of hemodynamic anomalies having required a treatment
consumption of propofol and remifentanil during the induction and the maintenance of the anaesthesia
extubation time, explicit memorisation
dysfunctions of each system
intraoperative volume loading and transfusion

Countries

France

Outcome results

None listed