Brief summary

The purpose of this study is to evaluate the efficacy of 3 different rapamycin-eluting-stent platforms to reduce coronary artery reblockage after stent implantation

Detailed description

Coronary artery reblockage remains still a drawback of percutaneous coronary interventions even in the era of drug-eluting stents (DES). DESs working principle consists of the delivery of controlled amounts of antiproliferative agents at the local level, which results in the suppression of neointimal proliferation, the main cause of lumen re-narrowing after stent implantation. At present, several DES platforms have been developed and evaluated for clinical use. They differ between them with regard to the stent type, anti-proliferative drug, presence of polymers employed for drug storage and modification of drug-release kinetics as well as type of polymer used for this purpose. Although their mid-term efficacy has been well-established, there is an ongoing debate on the potential of an increased incidence of late stent thrombosis, particularly after discontinuation of thienopyridine therapy, as well as of delayed onset of restenosis or catch-up phenomenon with DESs. Based on animal and human pathological data, investigators have linked the above-mentioned concerns to the presence of polymers in DESs, which have a proinflammatory and prothrombinogenic potential, and sometimes may induce a hypersensitivity reaction. This trial will compare the anti-restenotic efficacy of the permanent polymer (PP), biodegradable polymer (BP) and polymer-free (PF) rapamycin-eluting stents in patients with coronary artery disease. Cypher stent (PP) is a stainless steel stent coated with sirolimus with use of permanent polymers while the ISAR stent is a rough surface stainless steel stent which allows not only polymeric coating (for example biodegradable polymer, BP ISAR stent) but also coating without the need of polymer (PF ISAR stent) in the cath lab.

Interventions

DEVICErapamycin-eluting Stent with permanent polymer

due to randomization, rapamycin-eluting stent with permanent polymer will be implanted

DEVICErapamycin-eluting stent with biodegradable polymer

due to randomization, rapamycin-eluting stent with biodegradable polymer will be implanted

DEVICEpolymer-free, rapamycin-eluting stent

due to randomization, polymer-free.rapamycin-eluting stent will be implanted

Sponsors

Deutsches Herzzentrum Muenchen
Lead SponsorOTHER

Study design

Allocation
RANDOMIZED
Intervention model
PARALLEL
Primary purpose
TREATMENT
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* Patients older than age 18 with ischemic symptoms or evidence of myocardial ischemia in the presence of ≥50% de novo stenosis located in native coronary vessels. * Written, informed consent by the patient or her/his legally-authorized representative for participation in the study.

Exclusion criteria

* Target lesion located in the left main trunk or bypass graft. * In-stent restenosis. * Cardiogenic shock. * Malignancies or other comorbid conditions (for example severe liver, renal and pancreatic disease) with life expectancy less than 12 months or that may result in protocol non-compliance. * Known allergy to the study medications: aspirin, clopidogrel, rapamycin, stainless steel. * Pregnancy (present, suspected or planned) or positive pregnancy test. * Previous enrollment in this trial. * Patient's inability to fully cooperate with the study protocol.

Design outcomes

Primary

MeasureTime frame
in-stent late luminal lossat 6 to 8-month follow-up angiogram

Secondary

MeasureTime frame
In-segment binary angiographic restenosisat 6 to 8-month follow-up angiogram
Need of target lesion revascularizationat 9-month follow-up
Combined incidence of death or myocardial infarctionat 9-month follow-up
Incidence of stent thrombosis.at 9-month follow-up

Countries

Germany

Outcome results

None listed