Skip to content

The ENDEAVOR Pharmacokinetic (PK) Registry: The Medtronic Endeavor Drug Eluting Coronary Stent System

Evaluation of Pharmacokinetics (PK) and Safety of the Medtronic Endeavor Drug (ABT-578) Eluting Coronary Stent System in De Novo Native Coronary Artery Lesions

Status
Completed
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT00314275
Acronym
ENDEAVOR PK
Enrollment
43
Registered
2006-04-13
Start date
2006-01-31
Completion date
2011-08-31
Last updated
2012-04-20

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Coronary Artery Disease

Keywords

Pharmacokinetics, Coronary Artery Disease, PCI, Drug Eluting Stent

Brief summary

The purpose of this study is to evaluate the pharmacokinetics (PK) and safety associated with ABT-578 administered using the Medtronic Endeavor Drug Eluting Coronary Stent system in the treatment of single de novo lesions in native coronary arteries between 2.5 - 3.5 mm in diameter.

Interventions

Drug eluting stent

DEVICEEndeavor

Drug eluting stent

Sponsors

Medtronic Vascular
Lead SponsorINDUSTRY

Study design

Allocation
NON_RANDOMIZED
Intervention model
SINGLE_GROUP
Primary purpose
TREATMENT
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* The patient is at least 18 years of age. * The patient has clinical evidence of ischemic heart disease, stable or unstable angina, silent ischemia, or a positive functional study. * The patient is an acceptable candidate for percutaneous transluminal coronary angioplasty (PTCA), stenting, and emergent coronary artery bypass graft (CABG) surgery. * Female patients of childbearing potential must have a negative pregnancy test within 7 days before the procedure. * The patient or patient's legal representative has been informed of the nature of the study and agrees to its provisions and has provided written informed consent as approved by the Institutional Review Board of the respective clinical site.

Exclusion criteria

* A known hypersensitivity or contraindication to aspirin, heparin or bivalirudin, ticlopidine or clopidogrel, cobalt, nickel, chromium, molybdenum, polymer coatings, or a sensitivity to contrast media, which cannot be adequately pre-medicated. * History of an allergic reaction or significant sensitivity to drugs similar to ABT-578, rapamycin, tacrolimus, everolimus, or any other analog or derivative. * A platelet count \< 100,000 cells/mm³ or \> 700,000 cells/mm³, or a white blood cell (WBC) count \< 3,000 cells/mm³. * A creatinine level \> 2.0 mg/dL within seven days prior to index procedure. Evidence of an acute myocardial infarction within 72 hours of the intended treatment (defined as: Q wave or non-Q wave myocardial infarction having creatine kinase \[CK\] enzymes greater than or equal to 2 X the upper laboratory normal with the presence of a creatine kinase myocardial-band isoenzyme \[CK-MB\] elevated above the institution's upper limit of normal). * Previous percutaneous coronary intervention (PCI) of the target vessel within 9 months pre-procedure. * Planned PCI of any vessel within 30 days post-procedure. * During the index procedure, the target lesion requires treatment with a device other than PTCA prior to stent placement (such as, but not limited to: cutting balloon, directional coronary atherectomy, excimer laser, rotational atherectomy, thrombectomy, etc.). * History of a stroke or transient ischemic attack within the prior 6 months. Active peptic ulcer or upper gastrointestinal (GI) bleeding within the prior 6 months. * History of bleeding diathesis or coagulopathy or will refuse blood transfusions. * Concurrent medical condition with a life expectancy of less than 12 months. Any previous or planned treatment of the target vessel with anti-restenotic therapies including, but not limited to, brachytherapy. * Currently participating in an investigational drug or another device study that has not completed the primary endpoint or that clinically interferes with the current study endpoints; or requires coronary angiography, intravascular ultrasound (IVUS) or other coronary artery imaging procedures.

Design outcomes

Primary

MeasureTime frame
Pharmacokinetic parameters (Cmax, Tmax, AUC, T1/2, CL, etc.)9 months

Secondary

MeasureTime frame
Major adverse cardiac event (MACE) rate30 days, 6, 9 and 12 months
Target site revascularization (TSR), target vessel revascularization (TVR), and target vessel failure (TVF) rate9 months
For patients receiving overlapping stents at the target lesion: angiographic parameters (in-stent and in-segment), including: late lumen loss8 months
Late loss index9 months
Success (device, lesion, and procedure)9 months
Minimum luminal diameter (MLD)9 months
Percent diameter stenosis (%DS)9 months
Neointimal hyperplastic volume as measured by intravascular ultrasound (IVUS)8 months
Angiographic binary restenosis (ABR) rate9 months

Countries

United States

Outcome results

None listed