Skip to content

Safety of Inhaled Insulin With Type 1 and Type 2 Diabetes

Pulmonary Outcomes Within a 2-Year Period in Subjects With Diabetes Mellitus Treated With Technosphere /Insulin or Usual Antidiabetic Treatment and in Subjects Without Abnormalities in Glucose Control.

Status
Completed
Phases
Phase 3
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT00308737
Enrollment
2053
Registered
2006-03-30
Start date
2005-06-30
Completion date
2008-10-31
Last updated
2014-10-16

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Diabetes, Type 1, Diabetes, Type 2

Brief summary

Pulmonary Safety in Diabetics with T/I

Interventions

DRUGUsual Care

Subjects will receive antidiabetes treatment at the discretion of their physicians

Sponsors

Mannkind Corporation
Lead SponsorINDUSTRY

Study design

Allocation
RANDOMIZED
Intervention model
PARALLEL
Primary purpose
TREATMENT
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
18 Years to 70 Years
Healthy volunteers
Yes

Inclusion criteria

* For All Subjects: * Nonsmoking * Body mass index \<42 kg/m2 * FEV1 greater than or equal to 70% of predicted , DLco and TLC greater than or equal to 80% of predicted at screening, * No abnormalities in screening pulmonary radiology * For Subjects with diabetes mellitus: * Type 1 or type 2 diabetes for at least 2 years * HbA1c greater than or equal to 6.6 % and less than or equal to 12.0 % * For Subjects without abnormalities in glucose control: * No history of diabetes * Normal results from a formal glucose tolerance test

Exclusion criteria

* History of chronic obstructive pulmonary disease, asthma, or other significant pulmonary disease * Significant renal, hepatic, or cardiac disease * Women who are pregnant, lactating, or planning on becoming pregnant * Subjects who have participated in studies of other investigational drugs within the previous 3 months * Evidence of severe complications of diabetes

Design outcomes

Primary

MeasureTime frameDescription
Change From Baseline to Month 24 in Forced Expiratory Volume in 1 Second (FEV1) by MMRM for TI vs Usual CareBaseline to Month 24Change from Baseline to End of Study in FEV1 by MMRM
FEV1 Decrease of ≥ 15% From Baseline Value at Last Measurement for TI vs Usual CareBaseline to Month 24FEV1 decrease of ≥ 15% from Baseline value at last measurement

Secondary

MeasureTime frameDescription
Change From Baseline to Month 24 in Total Lung Capacity (TLC) by MMRMBaseline to Month 24Change from baseline to Month 24 in TLC by MMRM
Change From Baseline to Month 24 in Hemoglobin Corrected DLco by MMRMBaseline to Month 24Change from baseline to Month 24 in hemoglobin-corrected DLco by MMRM
Forced Vital Capacity (FVC) Decrease of ≥ 15% From Baseline Value at Last MeasurementBaseline to Month 24FVC Decrease of ≥15% from Baseline Value at Last Measurement
Total Lung Capacity (TLC) Decrease of ≥ 15% From Baseline Value at Last MeasurementBaseline to Month 24TLC Decrease of ≥ 15% from Baseline Value at Last Measurement
Change From Baseline to Last Measurement in FEV1 for TI vs Usual CareBaseline to Month 24Change from Baseline to last measurement(Month 24) in FEV1
Hemoglobin-Corrected Diffusing Capacity of the Lung for Carbon Monoxide (DLco) Decrease of >3 ml/Min/mmHg From Baseline Value at Last MeasurementBaseline to Month 24Hemoglobin-corrected DLco decrease of \>3 ml/min/mmHg from baseline value at last measurement
Change From Baseline in Glycated Hemoglobin A1c (HbA1c) at Last Measurement for TI vs Usual CareBaseline to Month 24Change from baseline in HbA1c at last measurement
Change in Weight From Baseline at Month 24Baseline to Month 24Change from baseline in weight at Month 24
Hemoglobin-Corrected Diffusing Capacity of the Lung for Carbon Monoxide (DLco) Decrease of ≥ 15% From Baseline Value at Last MeasurementBaseline to Month 24Hemoglobin-corrected DLco decrease of ≥ 15% from baseline value at last measurement
Change From Baseline to Month 24 in Forced Vital Capacity (FVC) by MMRMBaseline to Month 24Change from Baseline to Month 24 in FVC by MMRM

Countries

Canada, Czechia, Poland, Russia, Spain, Ukraine, United Kingdom, United States

Participant flow

Recruitment details

First subject enrolled July 25, 2005 Multi-national trial conducted in Canada, Czech Republic, Poland, Russia, Spain, Ukraine, UK, and US

Pre-assignment details

Subjects were required to meet all inclusion/exclusion criteria 3741 screened/2053 eligible of which all were randomized, including 164 non-diabetics - 1688 screen failures 17 diabetics randomized but not dosed 1 non-diabetic elected not to participate

Participants by arm

ArmCount
Technosphere® Insulin
Technosphere Insulin
923
Usual Care
Usual care
949
Non-diabetes
Subjects without abnormalities in glucose control
163
Total2,035

Withdrawals & dropouts

PeriodReasonFG000FG001FG002
Overall StudyAdverse Event10490
Overall StudyDeath430
Overall StudyLost to Follow-up56805
Overall StudyPhysician Decision1521
Overall StudyProtocol Violation3495
Overall StudyVarious32208
Overall StudyWithdrawal by Subject21816618

Baseline characteristics

CharacteristicTechnosphere® InsulinUsual CareNon-diabetesTotal
Age, Continuous50.8 years
STANDARD_DEVIATION 11.55
50.4 years
STANDARD_DEVIATION 11.62
38.2 years
STANDARD_DEVIATION 12.59
49.6 years
STANDARD_DEVIATION 12.15
Body mass index29.87 kilograms per meter squared
STANDARD_DEVIATION 5.366
29.76 kilograms per meter squared
STANDARD_DEVIATION 5.035
25.27 kilograms per meter squared
STANDARD_DEVIATION 4.494
29.5 kilograms per meter squared
STANDARD_DEVIATION 5.29
HbA1c8.7 percentage
STANDARD_DEVIATION 1.39
8.7 percentage
STANDARD_DEVIATION 1.38
0 percentage
STANDARD_DEVIATION 0
8.4 percentage
STANDARD_DEVIATION 1.61
Sex: Female, Male
Female
366 Participants371 Participants92 Participants829 Participants
Sex: Female, Male
Male
557 Participants578 Participants71 Participants1206 Participants
Weight87.69 kilograms
STANDARD_DEVIATION 18.628
87.53 kilograms
STANDARD_DEVIATION 17.638
74.35 kilograms
STANDARD_DEVIATION 16.204
86.6 kilograms
STANDARD_DEVIATION 18.33

Adverse events

Event typeEG000
affected / at risk
EG001
affected / at risk
EG002
affected / at risk
deaths
Total, all-cause mortality
— / —— / —— / —
other
Total, other adverse events
559 / 923472 / 94947 / 163
serious
Total, serious adverse events
92 / 92391 / 9495 / 163

Outcome results

Primary

Change From Baseline to Month 24 in Forced Expiratory Volume in 1 Second (FEV1) by MMRM for TI vs Usual Care

Change from Baseline to End of Study in FEV1 by MMRM

Time frame: Baseline to Month 24

Population: Intention to Treat (ITT)

ArmMeasureValue (MEAN)Dispersion
Technosphere® InsulinChange From Baseline to Month 24 in Forced Expiratory Volume in 1 Second (FEV1) by MMRM for TI vs Usual Care-0.16 litersStandard Deviation 0.208
Usual CareChange From Baseline to Month 24 in Forced Expiratory Volume in 1 Second (FEV1) by MMRM for TI vs Usual Care-0.12 litersStandard Deviation 0.211
Comparison: Mixed model repeated measures with fixed effects diabetes type, visit, pooled site and treatment and baseline FEV1 as a covariate95% CI: [0.014, 0.06]Mixed Models Analysis
Primary

FEV1 Decrease of ≥ 15% From Baseline Value at Last Measurement for TI vs Usual Care

FEV1 decrease of ≥ 15% from Baseline value at last measurement

Time frame: Baseline to Month 24

Population: Intention to Treat (ITT)

ArmMeasureValue (NUMBER)
Technosphere® InsulinFEV1 Decrease of ≥ 15% From Baseline Value at Last Measurement for TI vs Usual Care42 Participants
Usual CareFEV1 Decrease of ≥ 15% From Baseline Value at Last Measurement for TI vs Usual Care27 Participants
Comparison: Logistic regression excluding non-diabetics95% CI: [-4.5578, -0.3956]Regression, Logistic
Secondary

Change From Baseline in Glycated Hemoglobin A1c (HbA1c) at Last Measurement for TI vs Usual Care

Change from baseline in HbA1c at last measurement

Time frame: Baseline to Month 24

Population: Intention to treat (ITT) with last observation carried forward (LOCF)

ArmMeasureValue (MEAN)Dispersion
Technosphere® InsulinChange From Baseline in Glycated Hemoglobin A1c (HbA1c) at Last Measurement for TI vs Usual Care-0.42 percentageStandard Deviation 1.41
Usual CareChange From Baseline in Glycated Hemoglobin A1c (HbA1c) at Last Measurement for TI vs Usual Care-0.49 percentageStandard Deviation 1.37
Secondary

Change From Baseline to Last Measurement in FEV1 for TI vs Usual Care

Change from Baseline to last measurement(Month 24) in FEV1

Time frame: Baseline to Month 24

Population: Intention to Treat (ITT) with Last Observation Carried Forward (LOCF)

ArmMeasureValue (LEAST_SQUARES_MEAN)
Technosphere® InsulinChange From Baseline to Last Measurement in FEV1 for TI vs Usual Care-0.128 liters
Usual CareChange From Baseline to Last Measurement in FEV1 for TI vs Usual Care-0.092 liters
Comparison: ANCOVA model with treatment site, diabetes type, and baseline FEV195% CI: [0.016, 0.057]ANCOVA
Secondary

Change From Baseline to Month 24 in Forced Vital Capacity (FVC) by MMRM

Change from Baseline to Month 24 in FVC by MMRM

Time frame: Baseline to Month 24

Population: Intention to Treat (ITT)

ArmMeasureValue (MEAN)Dispersion
Technosphere® InsulinChange From Baseline to Month 24 in Forced Vital Capacity (FVC) by MMRM-0.14 litersStandard Deviation 0.242
Usual CareChange From Baseline to Month 24 in Forced Vital Capacity (FVC) by MMRM-0.11 litersStandard Deviation 0.262
Non-diabetesChange From Baseline to Month 24 in Forced Vital Capacity (FVC) by MMRM-0.09 litersStandard Deviation 0.21
Comparison: Mixed model repeated measures with fixed effects diabetes type, visit, pooled site and treatment and baseline FVC as a covariate95% CI: [0.008, 0.061]Mixed Models Analysis
Secondary

Change From Baseline to Month 24 in Hemoglobin Corrected DLco by MMRM

Change from baseline to Month 24 in hemoglobin-corrected DLco by MMRM

Time frame: Baseline to Month 24

Population: participants in ITT population with available data

ArmMeasureValue (MEAN)Dispersion
Technosphere® InsulinChange From Baseline to Month 24 in Hemoglobin Corrected DLco by MMRM-1.60 mL/min/mmHgStandard Deviation 2.83
Usual CareChange From Baseline to Month 24 in Hemoglobin Corrected DLco by MMRM-1.36 mL/min/mmHgStandard Deviation 2.862
Non-diabetesChange From Baseline to Month 24 in Hemoglobin Corrected DLco by MMRM-1.33 mL/min/mmHgStandard Deviation 3.203
Comparison: Mixed model repeated measures with fixed effects diabetes type, visit, pooled site, and treatment and baseline TLC as a covariate95% CI: [-0.037, 0.574]Mixed Models Analysis
Secondary

Change From Baseline to Month 24 in Total Lung Capacity (TLC) by MMRM

Change from baseline to Month 24 in TLC by MMRM

Time frame: Baseline to Month 24

Population: participants in ITT population with available data

ArmMeasureValue (MEAN)Dispersion
Technosphere® InsulinChange From Baseline to Month 24 in Total Lung Capacity (TLC) by MMRM-0.05 litersStandard Deviation 0.321
Usual CareChange From Baseline to Month 24 in Total Lung Capacity (TLC) by MMRM-0.07 litersStandard Deviation 0.322
Non-diabetesChange From Baseline to Month 24 in Total Lung Capacity (TLC) by MMRM-0.02 litersStandard Deviation 0.297
Comparison: Mixed model repeated measures with fixed effects diabetes type, visit, pooled site, and treatment and baseline TLC as a covariate95% CI: [-0.042, 0.031]Mixed Models Analysis
Secondary

Change in Weight From Baseline at Month 24

Change from baseline in weight at Month 24

Time frame: Baseline to Month 24

Population: Safety population at Month 24

ArmMeasureValue (MEAN)Dispersion
Technosphere® InsulinChange in Weight From Baseline at Month 241.0 kilogramsStandard Deviation 6.653
Usual CareChange in Weight From Baseline at Month 241.64 kilogramsStandard Deviation 5.066
Non-diabetesChange in Weight From Baseline at Month 241.19 kilogramsStandard Deviation 4.457
Comparison: Two sample t-testp-value: 0.112t-test, 2 sided
Secondary

Forced Vital Capacity (FVC) Decrease of ≥ 15% From Baseline Value at Last Measurement

FVC Decrease of ≥15% from Baseline Value at Last Measurement

Time frame: Baseline to Month 24

Population: participants in ITT population with available data

ArmMeasureValue (NUMBER)
Technosphere® InsulinForced Vital Capacity (FVC) Decrease of ≥ 15% From Baseline Value at Last Measurement23 participants
Usual CareForced Vital Capacity (FVC) Decrease of ≥ 15% From Baseline Value at Last Measurement17 participants
Non-diabetesForced Vital Capacity (FVC) Decrease of ≥ 15% From Baseline Value at Last Measurement2 participants
Comparison: Logistic regression excluding non-diabetics95% CI: [0.3432, 1.2219]Regression, Logistic
Secondary

Hemoglobin-Corrected Diffusing Capacity of the Lung for Carbon Monoxide (DLco) Decrease of ≥ 15% From Baseline Value at Last Measurement

Hemoglobin-corrected DLco decrease of ≥ 15% from baseline value at last measurement

Time frame: Baseline to Month 24

Population: participants in ITT population with available data

ArmMeasureValue (NUMBER)
Technosphere® InsulinHemoglobin-Corrected Diffusing Capacity of the Lung for Carbon Monoxide (DLco) Decrease of ≥ 15% From Baseline Value at Last Measurement105 Participants
Usual CareHemoglobin-Corrected Diffusing Capacity of the Lung for Carbon Monoxide (DLco) Decrease of ≥ 15% From Baseline Value at Last Measurement108 Participants
Non-diabetesHemoglobin-Corrected Diffusing Capacity of the Lung for Carbon Monoxide (DLco) Decrease of ≥ 15% From Baseline Value at Last Measurement20 Participants
Comparison: Logistic regression excluding non-diabetics95% CI: [0.6703, 1.1958]Regression, Logistic
Secondary

Hemoglobin-Corrected Diffusing Capacity of the Lung for Carbon Monoxide (DLco) Decrease of >3 ml/Min/mmHg From Baseline Value at Last Measurement

Hemoglobin-corrected DLco decrease of \>3 ml/min/mmHg from baseline value at last measurement

Time frame: Baseline to Month 24

Population: participants in ITT population with available data

ArmMeasureValue (NUMBER)
Technosphere® InsulinHemoglobin-Corrected Diffusing Capacity of the Lung for Carbon Monoxide (DLco) Decrease of >3 ml/Min/mmHg From Baseline Value at Last Measurement181 Participants
Usual CareHemoglobin-Corrected Diffusing Capacity of the Lung for Carbon Monoxide (DLco) Decrease of >3 ml/Min/mmHg From Baseline Value at Last Measurement181 Participants
Non-diabetesHemoglobin-Corrected Diffusing Capacity of the Lung for Carbon Monoxide (DLco) Decrease of >3 ml/Min/mmHg From Baseline Value at Last Measurement40 Participants
Comparison: Logistic regression excluding non-diabetics95% CI: [0.6722, 1.077]Regression, Logistic
Secondary

Total Lung Capacity (TLC) Decrease of ≥ 15% From Baseline Value at Last Measurement

TLC Decrease of ≥ 15% from Baseline Value at Last Measurement

Time frame: Baseline to Month 24

Population: participants in ITT population with available data

ArmMeasureValue (NUMBER)
Technosphere® InsulinTotal Lung Capacity (TLC) Decrease of ≥ 15% From Baseline Value at Last Measurement7 Participants
Usual CareTotal Lung Capacity (TLC) Decrease of ≥ 15% From Baseline Value at Last Measurement6 Participants
Non-diabetesTotal Lung Capacity (TLC) Decrease of ≥ 15% From Baseline Value at Last Measurement1 Participants
Comparison: Logistic regression excluding non-diabetics95% CI: [0.251, 2.2431]Regression, Logistic

Source: ClinicalTrials.gov · Data processed: Mar 12, 2026