Effects of Inspiration Rise Time on Work of Breathing and Comfort of Conscious Patients on Mechanical Ventilation

Status
Completed
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT00294879
Enrollment
10
Registered
2006-02-22
Start date
2006-02-28
Completion date
2008-03-31
Last updated
2008-06-02

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Mechanical Ventilation

Brief summary

Introduction Pressure Support Ventilation is widely used in patients in the ICU. Matching the patient's respiratory needs with adequate ventilator settings is necessary to ensure a low work of breathing (WOB) and maximal patient comfort. The inspiratory rise time (IRT) determines the time to reach the selected airway pressure. A short IRT results in a high peak inspiratory flow and a short time to reach that peak, but is also associated with the development of turbulent flow, resulting in increased WOB. Aim of this study is to investigate the effects of different IRT settings on WOB and patient comfort during pressure support ventilation. Methods We will performed a prospective, single blind cohort study in patients on Pressure Support Ventilation. 10 healthy adult patients admitted to the ICU after elective facial or neck surgery will be included. All patients will be ventilated in pressure support mode using a Servo 300 ventilator (Siemens. Elema, Solna, Sweden), with a positive end expiratory pressure of 5 cm H2O, pressure support level of 12 cm H2O above PEEP and an inspiratory oxygen fraction of 0.40. Patients have to be awake and cooperative (Ramsay 2). WOB will be measured with an esophageal balloon, and miniature flowmeter (Bicore system). Breathing comfort will be evaluated using a visual analogue scale (VAS) ranging from 1 to 10. WOB and patient comfort will be measured (in random order) at 0, 5, and 10% IRT. For statistical analysis the two-way analysis of variance will used. A p value of \< 0.05 will be considered statistically significant.

Detailed description

Introduction Pressure Support Ventilation is widely used in patients in the ICU. Matching the patient's respiratory needs with adequate ventilator settings is necessary to ensure a low work of breathing (WOB) and maximal patient comfort. The inspiratory rise time (IRT) determines the time to reach the selected airway pressure. A short IRT results in a high peak inspiratory flow and a short time to reach that peak, but is also associated with the development of turbulent flow, resulting in increased WOB. Aim of this study is to investigate the effects of different IRT settings on WOB and patient comfort during pressure support ventilation. Methods We will performed a prospective, single blind cohort study in patients on Pressure Support Ventilation. 10 healthy adult patients admitted to the ICU after elective facial or neck surgery will be included. All patients will be ventilated in pressure support mode using a Servo 300 ventilator (Siemens. Elema, Solna, Sweden), with a positive end expiratory pressure of 5 cm H2O, pressure support level of 12 cm H2O above PEEP and an inspiratory oxygen fraction of 0.40. Patients have to be awake and cooperative (Ramsay 2). WOB will be measured with an esophageal balloon, and miniature flowmeter (Bicore system). Breathing comfort will be evaluated using a visual analogue scale (VAS) ranging from 1 to 10. WOB and patient comfort will be measured (in random order) at 0, 5, and 10% IRT. For statistical analysis the two-way analysis of variance will used. A p value of \< 0.05 will be considered statistically significant.

Interventions

PROCEDUREpressure support ventilation at 0, 5, and 10% IRT

Sponsors

Radboud University Medical Center
Lead SponsorOTHER

Study design

Allocation
RANDOMIZED
Intervention model
CROSSOVER
Masking
SINGLE

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* awake and cooperative patient * ICU admission following surgery of head or neck

Exclusion criteria

* coagulopathy * inability to sit * hypoxemia and/or hypercapnia and /or hypocapnia * Pain score \> 5 (on scale 1-10) * esophageal abnormalities * Pregnancy * COPD

Design outcomes

Primary

MeasureTime frame
Work of breathing

Secondary

MeasureTime frame
patient comfort