Skip to content

Phacoemulsification Sleeves

Determination of Surgical Efficacy and Most Efficient Surgical Parameters for Use With the 2.2, 2.8, and 3.0mm Phacoemulsification Sleeves Used With the Alcon Infinity 1.1mm ABS Flared Tip

Status
Completed
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT00289068
Enrollment
44
Registered
2006-02-09
Start date
2006-01-31
Completion date
2007-09-30
Last updated
2023-12-15

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Cataract

Keywords

cataract surgery, phacoemulsification sleeve

Brief summary

Incision size in cataract surgery is related to induced surgical astigmatism, chamber stability, and surgical efficiency. Sleeves of different diameters change the size of the surgical incision and amount of fluid allowed into the eye during the surgical procedure for a given set of surgical parameters. Optimization of surgical parameters requires review of surgical efficiency including: fluid usage, energy usage, and total surgical time. With optimized surgical parameters recommendations can be made to increase the efficiency and safety of cataract surgery.

Detailed description

No scientific data has been presented comparing the surgical efficiency of the 2.2, 2.8, and 3.0 mm diameter phacoemulsification sleeves for the Alcon Infinity 1.1 mm flare abs tip or the changes in surgical parameters which optimize their performance. Fifty patients per sleeve group will undergo standard cataract extraction with documentation of surgical parameters used for each group. The goal of the study is to determine the most efficient surgical settings for each sleeve diameter and determine statistically the surgical parameters which optimize the use of each phacoemulsification sleeve. Purpose: The goal of the study is to determine the most efficient surgical settings for each sleeve diameter and determine statistically the surgical parameters which optimize the use of each phacoemulsification sleeve. Design: The study is designed to allow for scientific evaluation and publication of efficiency parameters using phacoemulsification sleeves of 2.2, 2.8, and 3.0 mm. The proposed study is a prospective nonrandomized clinical investigation of 50 patients per sleeve group. Methods: Data gathered at the time of surgery will include standard surgical parameters including: Total surgical time, total phacoemulsification/torsional time/power, total volume of infusion fluid, aspiration level, and vacuum level. Post-operative data will include: Post-op day one and week three corneal clarity (clear, would edema, central edema), anterior chamber cell seen in a 2mm 16x magnified slit-lamp biomicroscopic view focused in the aqueous humor (Grade 0 = 0 cells, 1 = up to 10 cells, 2 = 10 to 20 cells, 3 = 20 to 30 cells, 4 = too numerous to count), and uncorrected and/or best corrected visual acuity.

Interventions

PROCEDUREPhacoemulsification Sleeve surgery

Group 2.2 mm surgery setting

PROCEDUREPhacoemulsification Sleeves surgery

Group 2.8 mm surgery setting

PROCEDUREPhacoemulsification Sleeves

Group 3.0 mm surgery setting

Sponsors

University of Oklahoma
Lead SponsorOTHER

Study design

Observational model
COHORT
Time perspective
PROSPECTIVE

Eligibility

Sex/Gender
ALL
Age
18 Years to 100 Years
Healthy volunteers
No

Inclusion criteria

* requiring cataract surgery

Exclusion criteria

* n/a

Design outcomes

Primary

MeasureTime frame
Total surgical time, fluid volume, energy used to extract the cataract, post-operative cell and flare and corneal clarity2 years

Countries

United States

Outcome results

None listed