Skip to content

Frontier Registry II Bifurcation Stent System Registry

The Abbott Vascular MULTI -LINK FRONTIER Coronary Bifurcation Stent System Registry II

Status
Withdrawn
Phases
Phase 4
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT00286195
Enrollment
0
Registered
2006-02-03
Start date
2004-12-31
Completion date
2006-12-31
Last updated
2015-05-13

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Coronary Artery Disease

Brief summary

To assess the procedural success, performance, 30-day and 6 month clinical outcome of bifurcation stenting, and the six month incidence of clinically indicated target lesion revascularization with the use of the Abbott Vascular MULTI-LINK FRONTIER Coronary Bifurcation Stent System in patients with de novo or restenotic bifurcation lesions.

Detailed description

The purpose of this study is to assess the performance of the Abbott Vascular MULTI-LINK FRONTIER Coronary Bifurcation Stent System (CBSS) with one and six months clinical outcomes, when used for bifurcation de novo or restenotic lesion treatment. The device allows for a stent to be implanted in the main branch and simultaneous preservation and access of the side branch for balloon dilatation or stenting when indicated.

Interventions

DEVICEMulti-Link Frontier Coronary Stent System

Bare metal stent

Sponsors

Abbott Medical Devices
Lead SponsorINDUSTRY

Study design

Allocation
NON_RANDOMIZED
Intervention model
SINGLE_GROUP
Primary purpose
TREATMENT
Masking
NONE

Eligibility

Sex/Gender
ALL
Healthy volunteers
No

Inclusion criteria

* Other lesions in different epicardial vessels must be successfully treated prior to bifurcation procedure. * Native parent vessel suitable to receive at least a 2.5mm x 18mm FRONTIER stent (\>2.5mm and \<4.0mm diameter with a side branch of \>2.0mm) with a lesion length \<15mm determined by visual assessment . * Target main branch vessel must be a major epicardial native vessel. * Appropriate lesion morphology. * Target lesion is restenosis following original treatment by PTCA only (no in-stent restenosis).

Exclusion criteria

* Estimated artery reference diameter \<2.5mm * Patients with diffuse disease defined as long segments of abnormal vessel without interposed areas of normal vessel * Target lesion contains thrombus. * Target lesion is aorto-ostial or left main stem location. * Untreated lesion \>50% diameter stenosis proximal or distal to target lesion after the planned target lesion intervention. * Patients with a contraindication for anti-platelet / anti-coagulation therapy. * Target lesion distal to previously placed stents. * Fibrotic or calcified lesions that cannot be pre-dilated.

Design outcomes

Primary

MeasureTime frame
Incidence of Major Adverse Cardiac Events (MACE): Death, Q-wave and non-Q wave Myocardial Infarction, Target Lesion Revascularization (main branch and side branch) including PTCA and CABG at 6 months (180 days).180 days and one year
Acute ischemic, hemorrhagic and vascular complications.one year
Target Vessel Failure (TVF) rate (Death, Q-wave and non-Q-wave Myocardial Infarction and Target Vessel Revascularization (TVR) including PTCA and CABG at one month (30 days) and six months (180 days) follow up.6 months
Acute success of stent delivery, deployment, and post dilatation.30 days

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026