Skip to content

Study Evaluating Ways of Preventing Patients From Being Awake During High-Risk Surgery and Anesthesia

B-Unaware Study: Comparison of BIS-guided Anesthesia With End-Tidal Volatile-Guided Anesthesia to Decrease The Incidence of Awareness During High-Risk Surgery

Status
Completed
Phases
Phase 2Phase 3
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT00281489
Enrollment
2000
Registered
2006-01-24
Start date
2005-08-31
Completion date
Unknown
Last updated
2012-07-23

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Explicit Recall of Intra-operative Events

Keywords

Recall, Awareness, BIS, Anesthesia, Explicit Recall

Brief summary

The overall purpose of this study is to see if a Bispectral Index (BIS) monitor, a Food and Drug Administration (FDA) approved brain monitoring device, will help to reduce the risk of patients remembering being awake during surgery. The BIS monitor may be able measure how asleep a patient is during surgery. Using the BIS monitor to guide anesthesia will be compared with using the concentration of anesthetic gas to guide anesthesia.

Detailed description

General anesthesia is a state of drug-induced unconsciousness, during which patients should neither perceive nor recall noxious stimuli. Many patients facing surgery dread the prospect of being awake, in pain and unable to move owing to inadequate general anesthesia. A large multi-center study in the USA showed that, despite modern anesthesia techniques, the overall incidence of awareness or conscious recall remains about 0.1-0.2%. For high-risk (for awareness) surgery, such as cardiac surgery, trauma surgery and obstetric surgery, the incidence of conscious recall approaches 1%. This can lead to extreme anxiety and even posttraumatic stress disorder. Several monitors, including the Bispectral Index (BIS), which is based on processed electroencephalographic information, have been developed in an attempt to monitor depth of anesthesia. A recent landmark study suggested that harnessing the information provided by the BIS monitor decreases the incidence of explicit recall during high-risk surgical procedures from almost 1% to 0.1%. The possible impact of this study is enormous. The American Society of Anesthesiologists and the American Association of Nurse Anesthetists do not currently consider neurological monitors an essential part of routine anesthesia care. Increasingly, members of the anesthetic community are suggesting that for every patient undergoing general anesthesia, especially for procedures where the risk of awareness is considered higher, a neurological monitor, such as the BIS monitor, should be routinely applied. Explicit recall under general anesthesia is a major concern among members of the public and has even been featured on the popular Oprah Winfrey Show. Several patients presenting for surgery at Barnes Jewish Hospital have questioned whether the anesthesia provider would be using a BIS monitor to prevent awareness. Excluding the cost of the BIS monitor itself, the cost to use BIS is $17.50 for the disposable strip. If this monitor was to be used for every anesthetic administered at Barnes Jewish Hospital, this might translate to an annual cost of about $500,000. Explicit recall, especially when patients have been aware and unable to move, is a serious complication that frequently precipitates posttraumatic stress disorder. If indeed the BIS monitor does decrease the incidence of explicit recall, this could translate into a cost effective and more importantly clinically imperative intervention. Currently BIS monitors, or similar alternatives, are not used routinely to monitor depth of general anesthesia at Barnes Jewish Hospital. However, there are several concerns regarding the studies that have been conducted using the BIS monitor. There have been no parameters guiding administration of anesthesia in the control groups. BIS data have not been collected for patients in control groups, which prevents retrospective analysis and assessment of the true sensitivity, specificity, positive and negative predictive values of the BIS recordings. Most of the studies have been funded by the manufacturer of the device, which introduces a potential conflict of interest and investigator bias. In view of the current pressure to adopt BIS monitoring or an equivalent into the standard of anesthesia care, it is essential to conduct a study to address some of the concerns. The hypothesis of this proposed study is that an anesthetic algorithm can be designed for high-risk surgical patients such that the incidence of awareness will be equivalent to or lower than that in a group where anesthesia depth is guided by the BIS monitor.

Interventions

DEVICEBIS Monitor guided algorithm

BIS guided algorithm (BIS target 40 to 60) during anesthesia. Alarms when BIS is outside this range.

BEHAVIORALVolatile anesthetic guided algorithm

Volatile anesthetic guided algorithm. Target anesthetic concentration 0.7 to 1.3 minimum alveolar concentration during anesthesia. Alarms when anesthetic concentration not in this range.

Sponsors

The Foundation for Barnes-Jewish Hospital
CollaboratorOTHER
Washington University School of Medicine
Lead SponsorOTHER

Study design

Allocation
RANDOMIZED
Intervention model
PARALLEL
Primary purpose
PREVENTION
Masking
DOUBLE (Subject, Outcomes Assessor)

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

MUST HAVE: General Anesthesia with volatile anesthetic PATIENT CHARACTERISTICS Major Criteria (any 1 of the following:) 1. Medications - anticonvulsants, abuse of opiates, benzodiazepines, cocaine 2. EF\<40% 3. Prior history of awareness (recall) 4. History of difficult intubation or anticipated difficult intubation 5. ASA IV or V status 6. Aortic stenosis 7. End stage lung disease 8. Marginal exercise tolerance not secondary to musculoskeletal dysfunction 9. Pulmonary hypertension 10. Daily alcohol consumption Minor Criteria (any 2 of the following) 1. Beta blockers 2. COPD 3. Moderate exercise tolerance not secondary to musculoskeletal dysfunction 4. Smokes ≥2 packs per day 5. Morbid obesity BMI\>30 -

Exclusion criteria

1. Surgical procedure that prevents the use of the BIS (e.g surgery of forehead) 2. Patient positioning prevents use of the BIS 3. Surgery with wake-up test. 4. Less than 18 years of age 5. Vulnerable populations, such as those with dementia and those unable to provide informed consent. 6. Stroke with residual neurological deficits

Design outcomes

Primary

MeasureTime frame
The incidence of explicit recall of events during the surgical and anesthetic periods.30 days

Secondary

MeasureTime frame
2 Implicit memory (number).30 days
3 Dreaming.30 days
4 One-year mortality (and anesthetic depth).1 year
1 Anesthetic concentrations & BIS values in each group.1 day
6 Relation of events (e.g. movement) to BIS & ETAG.1 day
7 Relation of EMG to BIS.1 day
5 Relation of assessment to BIS value.30 days

Countries

United States

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Apr 5, 2026