Skip to content

Clinical Investigation of the Medtronic EnTrust™ Implantable Cardioverter Defibrillator (ICD), Model D153ATG

Clinical Investigation of the Medtronic EnTrust™ Implantable Cardioverter Defibrillator (ICD), Model D153ATG

Status
Completed
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT00273195
Enrollment
500
Registered
2006-01-09
Start date
2004-04-30
Completion date
2005-06-30
Last updated
2006-10-13

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Ventricular Arrhythmias

Keywords

Implantable Cardioverter Defibrillator, Anti-tachycardia pacing (ATP)

Brief summary

People who have a dangerously fast heart beat, or whose heart is at risk of stopping beating, may be in need of an electronic device called an implantable cardioverter defibrillator (ICD). An ICD is implanted surgically just under the skin in the upper chest area and it sends a strong electrical impulse, or shock, to the heart to return it to a normal rhythm. The purpose of this study was to evaluate the safety and efficacy of the EnTrust ICD device. A feature of this device allows it to send small, painless electrical impulses (Anti-tachycardia pacing or ATP) to the heart instead of shocking it out of a rhythm that is too fast. Stopping a dangerous heart rhythm this way does not cause any pain whereas a shock to the heart can feel like a punch in the chest. This device also allows the heart to beat on its own when it can and helping it (by pacing, or sending it electrical signals) when it needs help. This feature is important because previously studies have shown that pacing the heart too often can increase the risk for heart failure or for atrial fibrillation (having too rapid of heart beats in the atrium). This study is now complete and the device has since been approved by the FDA.

Interventions

DEVICEImplantable Cardioverter Defibrillator

Sponsors

Medtronic Cardiac Rhythm and Heart Failure
Lead SponsorINDUSTRY

Study design

Allocation
NON_RANDOMIZED
Intervention model
SINGLE_GROUP
Primary purpose
TREATMENT
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

Subjects with failure but no symptoms (NYHA Class I) or subjects with mild heart failure that only sometimes interferes with daily activities (NYHA Class II) Subjects who have, or are risk of having, a heart beat that is too fast and his/her doctor has determined he/she needs an implantable cardioverter defibrillator (ICD) Subjects who have, or are at risk of developing, rapid beats in the upper chambers of the heart (atrial tachyarrhythmias)

Exclusion criteria

Subjects with rapid heart beats in their ventricles (lower chambers of the heart) associated only with reversible causes Subjects with mechanical tricuspid heart valves (A structure in the heart, located between the right atrium and right ventricle, which allows blood to flow down from the atrium into the ventricle.)

Design outcomes

Primary

MeasureTime frame
Safety and efficacy at three months.

Secondary

MeasureTime frame
To evaluate how well the device distinguished between arrhythmias originating in the atrium versus those that originate in the ventricle.
To evaluate how well the anti-tachycardia pacing function works.
To observe the overall performance of the device system.

Countries

Austria, Canada, Denmark, Germany, Netherlands, Switzerland, United States

Outcome results

None listed